KGKirti Gupta

Kirti Gupta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kirti Gupta has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Model-Agnostic Semantics in Shipboard Systems Against Data Availability Attacks

    by Kirti Gupta, Subham Sahoo, Bijaya Ketan Panigrahi

    Data availability attacks, such as latency attacks, data dropouts and time synchronization attacks (TSAs) still remain a prime concern not only at the network level but also impair the control system performance & stability of the physical layer in medium voltage DC (MVDC) shipboard power systems (SPSs). To address its impact on the physical layer, we equip a model-agnostic semantic architecture that can compensate using process-aware delay compensation capabilities. Unlike traditional model predictive controllers (MPCs) with a limited prediction horizon, the proposed architecture offers long event-driven prediction even during large random delayed measurements. The semantic prediction policy is governed using the inner control loop dynamics of power generation modules (PGMs) to provide reconstructed signals for delay compensation. Its robustness has been extensively tested and validated on nominal 12 kV two-zone MVDC SPS, in an OPAL-RT environment for above-mentioned attacks. Overall, the proposed model-agnostic estimator (MAE) has the potential to significantly improve the resilience of SPSs against cyber-attacks without revealing any model information.


  • A privacy-preserving anomaly diagnosis scheme for AC microgrids

    by Kirti Gupta, Isha Chaudhary, Sai Sree Laya Chukkapalli, Anupam Joshi, Bijaya Ketan Panigrahi


  • A Monolithic Cybersecurity Architecture for Power Electronic Systems

    by Kirti Gupta, Subham Sahoo, Bijaya Ketan Panigrahi

    Power electronic systems (PES) face significant threats from various data availability and integrity attacks, significantly affecting the performance of communication networks and power system operation. As a result, several attack detection and reconstruction techniques are deployed, which makes it a costly & complex cybersecurity operational platform with significant room for incremental extensions for mitigation against future threats. Unlike the said traditional arrangements, our paper introduces a foundational approach by establishing a monolithic cybersecurity architecture (MCA) via incorporating semantic principles into the sampling process for distributed energy resources (DERs). This unified approach concurrently compensates for the intrusion challenges posed by cyber attacks by reconstructing signals using the dynamics of the inner control layer. This reconstruction considers essential semantic attributes, like Priority, Freshness, and Relevance to ensure resilient dynamic performance. Hence, the proposed scheme promises a generalized route to concurrently tackle a global set of cyber attacks in elevating the resilience of PES. Finally, rigorous validation on a modified IEEE 69-bus distribution system and a real-world South California Edison (SCE) 47-bus network, using OPAL-RT under diverse operating conditions, underscores its robustness, model-free design capability, scalability, and adaptability to dynamic cyber graphs and system reconfiguration.


  • Delay-Aware Semantic Sampling in Power Electronic Systems

    by Kirti Gupta, Subham Sahoo, Bijaya Ketan Panigrahi

    In power electronic systems (PES), attacks on data availability such as latency attacks, data dropouts, and time-synchronization attacks (TSAs) continue to pose significant threats to both the communication network and the control system performance. As per the conventional norms of communication engineering, PES still rely on time synchronized sampling, which translates every received message with equal importance. In this paper, we go beyond event-triggered sampling/estimation to integrate semantic principles into the sampling process for each distributed energy resource (DER), which not only compensates for delayed communicated signals by reconstruction of a new signal from the inner control layer dynamics, but also evaluates the reconstruction stage using key semantic requirements, namely Freshness, Relevance and Priority for good dynamic performance. As a result, the sparsity provided by event-driven sampling of internal control loop dynamics translates as semantics in PES. The proposed scheme has been extensively tested and validated on a modified IEEE 37-bus AC distribution system, under many operating conditions and noisy environment in OPAL-RT environment to establish its robustness, model-free design ability and adaptive behavior to dynamic cyber graph topologies.


  • Distinguishing Between Cyber Attacks and Faults in Power Electronic Systems—A Noninvasive Approach

    by Kirti Gupta, Subham Sahoo, Rabindra Mohanty, Bijaya Ketan Panigrahi, Frede Blaabjerg

    With increased cyber infrastructure in large power systems with inverter-based resources (IBRs), it remains highly susceptible to cyber attacks. Reliable and secure operations of such system under a large signal disturbance necessitate an anomaly diagnosis scheme, which is substantial for either selective operation of relays (during grid faults), or cybersecurity (during cyber attacks). This becomes a challenge for power electronic systems, as their characteristic response to such large signal disturbance is very fast. Hence, we accumulate our efforts in this paper to characterize between them accurately within a short time frame. A novel non-invasive anomaly diagnosis mechanism for IBRs is presented, which only requires locally measured voltage and frequency as inputs. Mapping these inputs in a X-Y plane, the characterization process is able to classify between the anomalies within 5 ms. To the best of our knowledge, this mechanism provides the fastest decision in comparison to the existing techniques, which also assists the equipped protection/cybersecurity technology to take corresponding decisions without enforcing any customization. The proposed scheme is validated on many systems using real-time (RT) simulations in OPAL-RT environment with HYPERSIM software and also on a hardware prototype. The results verify the effectiveness, scalability and accuracy of the proposed mechanism under different scenarios.


  • Open Access

    On the Assessment of Cyber Risks and Attack Surfaces in a Real-Time Co-Simulation Cybersecurity Testbed for Inverter-Based Microgrids

    by Kirti Gupta, Subham Sahoo, Bijaya Ketan Panigrahi, Frede Blaabjerg, Petar Popovski

    The integration of variable distributed generations (DGs) and loads in microgrids (MGs) has made the reliance on communication systems inevitable for information exchange in both control and protection architectures to enhance the overall system reliability, resiliency and sustainability. This communication backbone in turn also exposes MGs to potential malicious cyber attacks. To study these vulnerabilities and impacts of various cyber attacks, testbeds play a crucial role in managing their complexity. This research work presents a detailed study of the development of a real-time co-simulation testbed for inverter-based MGs. It consists of a OP5700 real-time simulator, which is used to emulate both the physical and cyber layer of an AC MG in real time through HYPERSIM software; and SEL-3530 Real-Time Automation Controller (RTAC) hardware configured with ACSELERATOR RTAC SEL-5033 software. A human–machine interface (HMI) is used for local/remote monitoring and control. The creation and management of HMI is carried out in ACSELERATOR Diagram Builder SEL-5035 software. Furthermore, communication protocols such as Modbus, sampled measured values (SMVs), generic object-oriented substation event (GOOSE) and distributed network protocol 3 (DNP3) on an Ethernet-based interface were established, which map the interaction among the corresponding nodes of cyber-physical layers and also synchronizes data transmission between the systems. The testbed not only provides a real-time co-simulation environment for the validation of the control and protection algorithms but also extends to the verification of various detection and mitigation algorithms. Moreover, an attack scenario is also presented to demonstrate the ability of the testbed. Finally, challenges and future research directions are recognized and discussed.


  • Adaptive Voltage Based Relay Setting for PV Connected Distribution System

    by Kirti Gupta, Saumendra Sarangi, Suraj Kumar Gadari

    Inverter based distributed generations (IBDGs) have gained popularity in order to reduce carbon emission from fossil fuel based power plants. The contribution of very low fault currents due to low thermal overload capability and low voltage ride through (LVRT) techniques applied to control the voltage has resulted in different voltage profile than the fault condition with conventional synchronous machines. As a result, integration of these sources in distribution grid has caused maloperation of conventional over current relays (OCRs). In this paper, the adaptive setting of the OCR has been proposed using estimated voltage considering the operation of LVRT. The validation of the method proposed is been investigated on an IEEE distribution system comprising of 12 buses, using DIgSILENT Power Factory 2018 software and results obtained are significantly better. Both the time of operation of relays is improved and coordination is maintained.