Pavan G. Malghan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pavan G. Malghan has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
- Malaya Kumar Hota
Department of Communication Engineering, School of Electronics Engineering, Vellore Institute of Technology, Vellore, Tamil Nadu, INDIA
4 shared publications
Latest Publications
- 23 June 2025
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 48 (3) , 1281-1298
An enhanced deep learning framework for muscle artifact removal from ECG signal integrating resnet, GCAB, and BI-LSTM
Electrocardiogram (ECG) signals are significantly distorted during recording by muscle artifact (MA), causing signal frequency overlap and making it difficult to interpret ECG data correctly. Deep learning (DL) methods for signal processing have shown promising results. However, there is a significant necessity in building proper DL models with appropriate datasets. We propose an enhanced hybrid deep learning framework called HRGB-Net based on residual neural network (ResNet), global channel attention block (GCAB), and bidirectional-long-short-term memory (Bi-LSTM) blocks for filtering the MA noise from ECG by using three distinctive MIT-BIH real-time datasets from the PhysioNet repository by creating suitable datasets for training. We use both raw ECG data and short-time Fourier-transformed (STFT) ECG data for comparative analysis with three neural network models: a convolutional neural Network (CNN), a fully connected neural network (FCNN), and a regression-based LSTM (Reg-LSTM-DNN) model to assess the proposed model. The signal-to-noise ratio (SNR) of noisy ECG signals is varied from - 7dB to 2dB to analyze the mean square error (MSE) and correlation coefficient (CC) performances after the denoising process. Our proposed method utilizes the regression ability to remove MA noise and generate a clean ECG signal with improved values of these signal parameters. The STFT-trained and tested ECG data shows better results than the raw ECG data for efficiently eliminating the MA with a 98.82% correlation coefficient and optimal MSE value of 0.053068. The results prove our proposed HRGB-Net model's remarkable ability to outperform the neural network models and other standard techniques.
- 23 June 2025
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 48 (3) , 1281-1298
An enhanced deep learning framework for muscle artifact removal from ECG signal integrating resnet, GCAB, and BI-LSTM
Electrocardiogram (ECG) signals are significantly distorted during recording by muscle artifact (MA), causing signal frequency overlap and making it difficult to interpret ECG data correctly. Deep learning (DL) methods for signal processing have shown promising results. However, there is a significant necessity in building proper DL models with appropriate datasets. We propose an enhanced hybrid deep learning framework called HRGB-Net based on residual neural network (ResNet), global channel attention block (GCAB), and bidirectional-long-short-term memory (Bi-LSTM) blocks for filtering the MA noise from ECG by using three distinctive MIT-BIH real-time datasets from the PhysioNet repository by creating suitable datasets for training. We use both raw ECG data and short-time Fourier-transformed (STFT) ECG data for comparative analysis with three neural network models: a convolutional neural Network (CNN), a fully connected neural network (FCNN), and a regression-based LSTM (Reg-LSTM-DNN) model to assess the proposed model. The signal-to-noise ratio (SNR) of noisy ECG signals is varied from - 7dB to 2dB to analyze the mean square error (MSE) and correlation coefficient (CC) performances after the denoising process. Our proposed method utilizes the regression ability to remove MA noise and generate a clean ECG signal with improved values of these signal parameters. The STFT-trained and tested ECG data shows better results than the raw ECG data for efficiently eliminating the MA with a 98.82% correlation coefficient and optimal MSE value of 0.053068. The results prove our proposed HRGB-Net model's remarkable ability to outperform the neural network models and other standard techniques.
- Open Access
- 8 August 2024
- Published by MECS Publisher in International Journal of Image, Graphics and Signal Processing
- Vol. 16 (4) , 56-73
50Hz Power Line Interference Removal from anElectrocardiogram Signal Using a VME-DWTBased Frequency Extraction and FilteringApproach
Removing undesirable artifacts in electrocardiogram signals is essential for biological signal processing as the signal gets distorted and makes appropriate investigation challenging. A primary source of distortion affecting recordings is the 50Hz power line interference. To get a high-quality recording, we used a filtering method based on an efficient decomposition technique known as variational mode extraction. This approach is similar to the variational mode decomposition methodology but with a few alterations in mathematical computation. First, it extracts the noise efficiently in a specific frequency band. Then, we apply the discrete wavelet transform to the signal, employing soft thresholding. As a result, it eliminates the extra noise and filters the electrocardiogram signal. We evaluated the efficacy of our proposed method using an arrhythmia database. Furthermore, we compared recent decomposition methods on six random signals using signal-to-noise ratios, mean square errors, correlation coefficients, and other signal features. Our method also efficiently eliminates varying amplitude of powerline noise and finally outperforms decomposition strategies regarding noise reduction and processing complexity across all signal parameters.
- 8 August 2024
- Published by MECS Publisher in International Journal of Image, Graphics and Signal Processing
- Vol. 16 (4) , 56-73
Open Access50Hz Power Line Interference Removal from anElectrocardiogram Signal Using a VME-DWTBased Frequency Extraction and FilteringApproach
Removing undesirable artifacts in electrocardiogram signals is essential for biological signal processing as the signal gets distorted and makes appropriate investigation challenging. A primary source of distortion affecting recordings is the 50Hz power line interference. To get a high-quality recording, we used a filtering method based on an efficient decomposition technique known as variational mode extraction. This approach is similar to the variational mode decomposition methodology but with a few alterations in mathematical computation. First, it extracts the noise efficiently in a specific frequency band. Then, we apply the discrete wavelet transform to the signal, employing soft thresholding. As a result, it eliminates the extra noise and filters the electrocardiogram signal. We evaluated the efficacy of our proposed method using an arrhythmia database. Furthermore, we compared recent decomposition methods on six random signals using signal-to-noise ratios, mean square errors, correlation coefficients, and other signal features. Our method also efficiently eliminates varying amplitude of powerline noise and finally outperforms decomposition strategies regarding noise reduction and processing complexity across all signal parameters.
- Open Access
- 29 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 54070-54079
An Improved VME Technique via Heap Based Optimization Algorithm and AWIT Method for PLI and MA Noise Elimination in ECG
Diagnosing cardiac conditions require careful examination of an electrocardiogram (ECG). However, a significant issue arises when capturing an ECG due to interference from various noises. Noises like power line interference (PLI) and muscle artifact (MA) change the morphology, making it difficult to interpret the original signal. Our research proposes an improved variational mode extraction (IVME) technique using a Heap-based optimization (HBO) algorithm and an automatic wavelet interval-dependent thresholding (AWIT) method to eliminate such noises. First, HBO uses the envelope entropy spectrum (EES) as the objective function to find the best fitness value for optimizing the VME parameter, known as penalty factor α. Then, we extract a specific mode using the optimal α value in VME to accurately remove PLI from the signal. Finally, the AWIT method automatically computes the intervals and their respective threshold values to remove excessive MA noise from the PLI-filtered ECG signal. We evaluate the efficiency of ten random real-time ECG signals from the MIT-BIH arrhythmia database. The result analysis proves that our algorithm can accurately extract the mode containing PLI and eradicate MA from the noisy ECG signal. It also shows improvement in signal parameters like signal-to-noise ratio (SNR improvement ), mean square error (MSE), and correlation coefficients (CC) with 36.7968 dB, 0.00030901, and 99.7278%, respectively.
- 29 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 54070-54079
Open AccessAn Improved VME Technique via Heap Based Optimization Algorithm and AWIT Method for PLI and MA Noise Elimination in ECG
Diagnosing cardiac conditions require careful examination of an electrocardiogram (ECG). However, a significant issue arises when capturing an ECG due to interference from various noises. Noises like power line interference (PLI) and muscle artifact (MA) change the morphology, making it difficult to interpret the original signal. Our research proposes an improved variational mode extraction (IVME) technique using a Heap-based optimization (HBO) algorithm and an automatic wavelet interval-dependent thresholding (AWIT) method to eliminate such noises. First, HBO uses the envelope entropy spectrum (EES) as the objective function to find the best fitness value for optimizing the VME parameter, known as penalty factor α. Then, we extract a specific mode using the optimal α value in VME to accurately remove PLI from the signal. Finally, the AWIT method automatically computes the intervals and their respective threshold values to remove excessive MA noise from the PLI-filtered ECG signal. We evaluate the efficiency of ten random real-time ECG signals from the MIT-BIH arrhythmia database. The result analysis proves that our algorithm can accurately extract the mode containing PLI and eradicate MA from the noisy ECG signal. It also shows improvement in signal parameters like signal-to-noise ratio (SNR improvement ), mean square error (MSE), and correlation coefficients (CC) with 36.7968 dB, 0.00030901, and 99.7278%, respectively.
- 19 March 2020
- Published by Springer Nature in Research on Biomedical Engineering
- Vol. 36 (2) , 171-186
A review on ECG filtering techniques for rhythm analysis
- 19 March 2020
- Published by Springer Nature in Research on Biomedical Engineering
- Vol. 36 (2) , 171-186
A review on ECG filtering techniques for rhythm analysis