Diego Tagnani
Research Subjects
Diego Tagnani has a total of 387 co-authors. Here are the top co-authors by number of shared publications:
- Antonio Budano
The Belle II Collaboration)
4 shared publications - Elisa Di Meco
INFN Laboratori Nazionali di Frascati
4 shared publications - Alessandro Saputi
INFN Sezione di Ferrara
3 shared publications - Cristina Martellini
The Belle II Collaboration)
3 shared publications - Daniele Paesani
INFN, Laboratori Nazionali del Sud, (LNS) Via S. Sofia 62, Catania, 95123 Italy
3 shared publications - E. Bernieri
Università degli Studi di Roma Tre 00146 Rome Italy
3 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (09) , P09025
A modular datalogger and slow-control platform for physics experiments with time-series telemetry and web dashboards
We present a NIM 2U slow-control system designed for continuous monitoring of environmental and facility parameters during data taking in nuclear-physics experiments. The architecture integrates a base controller board with eight channels for PT100/PT1000 probes and up to three plug-in extension boards, each providing SMA connections on the front panel. All boards adopt a 16-bit SAR ADC (AD7689) with an external 2.5 V reference, yielding an LSB of 38.15 μV and ensuring metrological uniformity across heterogeneous channel types [1,2]. The operating range for PT100/PT1000 probes spans -200 °C→ +300 °C, with a design accuracy at the 1 % level. The system includes modules dedicated to standard industrial signals 4–20 mA and 0–10 V (manual per-channel selection) and a module for current measurement in the 10 nA–150 μA range with automatic gain-range selection. The software chain publishes time series to Graphite and provides visualization through Grafana over Ethernet [1]. Representative performance measurements are reported for the RTD and Current Reader chains, including long-term stability tests with reference elements and calibration measurements over the operating range. A complete metrological characterization of all industrial input configurations remains part of future work.
- 1 September 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (09) , P09025
Open AccessA modular datalogger and slow-control platform for physics experiments with time-series telemetry and web dashboards
We present a NIM 2U slow-control system designed for continuous monitoring of environmental and facility parameters during data taking in nuclear-physics experiments. The architecture integrates a base controller board with eight channels for PT100/PT1000 probes and up to three plug-in extension boards, each providing SMA connections on the front panel. All boards adopt a 16-bit SAR ADC (AD7689) with an external 2.5 V reference, yielding an LSB of 38.15 μV and ensuring metrological uniformity across heterogeneous channel types [1,2]. The operating range for PT100/PT1000 probes spans -200 °C→ +300 °C, with a design accuracy at the 1 % level. The system includes modules dedicated to standard industrial signals 4–20 mA and 0–10 V (manual per-channel selection) and a module for current measurement in the 10 nA–150 μA range with automatic gain-range selection. The software chain publishes time series to Graphite and provides visualization through Grafana over Ethernet [1]. Representative performance measurements are reported for the RTD and Current Reader chains, including long-term stability tests with reference elements and calibration measurements over the operating range. A complete metrological characterization of all industrial input configurations remains part of future work.
- Open Access
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , C04021
A compact Optical Liquid Argon Facility at Roma Tre
In this paper we present a compact test facility for the measurement of optical properties of liquid argon as scintillator. The setup is under preparation at Roma Tre and it has a volume of 40 L liquid argon, which is liquefied from argon gas with a purity of ≥ 99.9999% vol. To readout the scintillation photons from liquid argon with the highest intensity near 127 nm, we use the vacuum ultraviolet silicon photomultipliers from Hamamatsu. By submerging the photon detectors directly inside the liquid argon, we can eliminate the systematics from the wavelength shifter and light guides which have been commonly used to detect the scintillation photons of liquid argon.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , C04021
Open AccessA compact Optical Liquid Argon Facility at Roma Tre
In this paper we present a compact test facility for the measurement of optical properties of liquid argon as scintillator. The setup is under preparation at Roma Tre and it has a volume of 40 L liquid argon, which is liquefied from argon gas with a purity of ≥ 99.9999% vol. To readout the scintillation photons from liquid argon with the highest intensity near 127 nm, we use the vacuum ultraviolet silicon photomultipliers from Hamamatsu. By submerging the photon detectors directly inside the liquid argon, we can eliminate the systematics from the wavelength shifter and light guides which have been commonly used to detect the scintillation photons of liquid argon.
- Top Cited PapersOpen Access
- 16 January 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (2) , 022701
First Results on the Search for Lepton Number Violating Neutrinoless Double- β Decay with the LEGEND-200 Experiment
The LEGEND Collaboration is searching for neutrinoless double-beta ( 0 ν β β ) decay by operating high-purity germanium detectors enriched in Ge 76 in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0 ν β β decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5 − 0.2 + 0.3 cts / ( keV ton yr ) in the 0 ν β β decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 × 10 26 yr on the half-life of 0 ν β β decay, reveals no evidence for a signal and sets a new observed lower limit at T 1 / 2 0 ν > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range m β β < 75 – 200 meV , depending on the adopted nuclear matrix element.
- 16 January 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (2) , 022701
Top Cited PapersOpen AccessFirst Results on the Search for Lepton Number Violating Neutrinoless Double- β Decay with the LEGEND-200 Experiment
The LEGEND Collaboration is searching for neutrinoless double-beta ( 0 ν β β ) decay by operating high-purity germanium detectors enriched in Ge 76 in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0 ν β β decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5 − 0.2 + 0.3 cts / ( keV ton yr ) in the 0 ν β β decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 × 10 26 yr on the half-life of 0 ν β β decay, reveals no evidence for a signal and sets a new observed lower limit at T 1 / 2 0 ν > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range m β β < 75 – 200 meV , depending on the adopted nuclear matrix element.
- Open AccessDesign and Commissioning of Readout Electronics for a $K_L^0$ and $μ$ Detector at the Belle II Experiment
The K-long and muon detector (KLM) constitutes the outer-most volume of the Belle II spectrometer at the interaction region of the SuperKEKB collider in Tsukuba, Japan. The KLM detector was partially upgraded since the Belle experiment by replacing many of its resistive-plate chambers with scintillators containing wavelength-shifting fibers and instrumenting it with silicon photomultipliers. We describe the readout electronics, firmware, and software created to control and acquire data from the scintillators and resistive-plate chambers.
Open AccessDesign and Commissioning of Readout Electronics for a $K_L^0$ and $μ$ Detector at the Belle II ExperimentThe K-long and muon detector (KLM) constitutes the outer-most volume of the Belle II spectrometer at the interaction region of the SuperKEKB collider in Tsukuba, Japan. The KLM detector was partially upgraded since the Belle experiment by replacing many of its resistive-plate chambers with scintillators containing wavelength-shifting fibers and instrumenting it with silicon photomultipliers. We describe the readout electronics, firmware, and software created to control and acquire data from the scintillators and resistive-plate chambers.
- Open Access
- 1 September 2023
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 18 (09) , P09007
The Front-End electronics for the liquid Argon instrumentation of the LEGEND-200 experiment
In this paper we provide a detailed technical description of the Front-End (FE) electronics for the liquid Argon instrumentation of the LEGEND-200 experiment, searching for the very rare, hypothetical neutrinoless double β decay process at the Italian Laboratori Nazionali del Gran Sasso. The design stems from the need to read out the silicon photo-multiplier response to the scintillation light in the liquid Argon with excellent single-photon resolution. The FE electronics is required to be placed far from the detectors to meet the experiment's radio-purity constraints. This constraint represents a challenge for a high signal-to-noise ratio. We address how this could be achieved in a stable way. The system was installed in July 2021 and has been commissioned with the rest of LEGEND-200, proving we could attain a very low overall level of electrical noise of 250 μV peak-to-peak.
- 1 September 2023
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 18 (09) , P09007
Open AccessThe Front-End electronics for the liquid Argon instrumentation of the LEGEND-200 experiment
In this paper we provide a detailed technical description of the Front-End (FE) electronics for the liquid Argon instrumentation of the LEGEND-200 experiment, searching for the very rare, hypothetical neutrinoless double β decay process at the Italian Laboratori Nazionali del Gran Sasso. The design stems from the need to read out the silicon photo-multiplier response to the scintillation light in the liquid Argon with excellent single-photon resolution. The FE electronics is required to be placed far from the detectors to meet the experiment's radio-purity constraints. This constraint represents a challenge for a high signal-to-noise ratio. We address how this could be achieved in a stable way. The system was installed in July 2021 and has been commissioned with the rest of LEGEND-200, proving we could attain a very low overall level of electrical noise of 250 μV peak-to-peak.
- 1 July 2023
- Published by IATED Academy in EDULEARN Proceedings
- Vol. 1, 2733-2737
TAKE A LOOK AT MODERN PHYSICS: VIRTUAL REALITY FOR SCHOOLS TO EXPLORE PARTICLE PHYSICS
- 1 July 2023
- Published by IATED Academy in EDULEARN Proceedings
- Vol. 1, 2733-2737
TAKE A LOOK AT MODERN PHYSICS: VIRTUAL REALITY FOR SCHOOLS TO EXPLORE PARTICLE PHYSICS
- Open Access
- 11 October 2022
- Published by MDPI AG in Instruments
- Vol. 6 (4) , 62
Crilin: A Semi-Homogeneous Calorimeter for a Future Muon Collider
Calorimeters, as other detectors, have to face the increasing performance demands of the new energy frontier experiments. For a future Muon Collider the main challenge is given by the Beam Induced Background that may pose limitations to the physics performance. However, it is possible to reduce the BIB impact by exploiting some of its characteristics by ensuring high granularity, excellent timing, longitudinal segmentation and good energy resolution. The proposed design, the Crilin calorimeter, is an alternative semi-homogeneous ECAL barrel for the Muon Collider based on Lead Fluoride Crystals (PbF) with a surface-mount UV-extended Silicon Photomultipliers (SiPMs) readout with an optimized design for a future Muon Collider.- 11 October 2022
- Published by MDPI AG in Instruments
- Vol. 6 (4) , 62
Open AccessCrilin: A Semi-Homogeneous Calorimeter for a Future Muon Collider
Calorimeters, as other detectors, have to face the increasing performance demands of the new energy frontier experiments. For a future Muon Collider the main challenge is given by the Beam Induced Background that may pose limitations to the physics performance. However, it is possible to reduce the BIB impact by exploiting some of its characteristics by ensuring high granularity, excellent timing, longitudinal segmentation and good energy resolution. The proposed design, the Crilin calorimeter, is an alternative semi-homogeneous ECAL barrel for the Muon Collider based on Lead Fluoride Crystals (PbF) with a surface-mount UV-extended Silicon Photomultipliers (SiPMs) readout with an optimized design for a future Muon Collider.