Masoud Abedinifar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Masoud Abedinifar has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Seniz Ertugrul
Department of Mechatronics Engineering, Izmir University of Economics, Balcova, Izmir 35330, Turkey
2 shared publications- Seniz Ertugrul
İzmir University of Economics
2 shared publications Bernd Friedrich
1 shared publication- Clint Hansen
Department of Neurology, University Hospital Schleswig-Holstein and Kiel University, Kiel, Germany
1 shared publication Dominic Feldhaus
1 shared publication- Fabian Diaz
Institute of Process Metallurgy and Metal Recycling IME, RWTH Aachen University, Intzestraße 3, 52056 Aachen, Germany
1 shared publication
Latest Publications
- Open Access
- 4 March 2026
- Published by MDPI AG in Biomechanics
- Vol. 6 (1) , 29
Joint Torque Errors Induced by Quasi-Static Assumptions in Lower Limb Biomechanics
Background/Objectives: Quasi-static inverse dynamics is widely used in biomechanical analyses due to its computational simplicity; however, neglecting inertial effects may introduce joint-specific torque estimation errors during dynamic movements. The purpose of this study was to quantify torque estimation errors introduced by quasi-static assumptions during bodyweight squats performed at different movement frequencies. Methods: A planar MATLAB-based (version R2022a) musculoskeletal model incorporating standard anthropometric parameters was developed to simulate squat motions at 1.00, 0.75, 0.50, and 0.25 Hz. Joint torques calculated using quasi-static inverse dynamics were compared with fully dynamic inverse dynamics at the ankle, knee, and hip. Model agreement was evaluated using Root Mean Square Error (RMSE), normalized percentage error relative to peak dynamic torque, and bootstrapped 95% confidence intervals (CI). Results: Quasi-static modeling produced negligible torque estimation errors at the ankle and knee across all movement frequencies, with percentage errors consistently below 0.1% and narrow confidence intervals. In contrast, the hip joint demonstrated a clear frequency-dependent underestimation of torque when inertial effects were neglected. At 1.00 Hz, the hip RMSE reached 14.4 Nm, corresponding to 14.01% of peak dynamic torque (95% CI: 13.97–14.06%). Error magnitude increased systematically with movement speed. Conclusions: The validity of quasi-static inverse dynamics strongly depends on joint location and movement frequency. While quasi-static models are appropriate for ankle and knee torque estimation during moderate-speed squats, accurate hip torque assessment during faster squats requires full dynamic modeling. These findings provide quantitative benchmarks to inform model selection in biomechanical research, rehabilitation engineering, and assistive device design.
- 4 March 2026
- Published by MDPI AG in Biomechanics
- Vol. 6 (1) , 29
Open AccessJoint Torque Errors Induced by Quasi-Static Assumptions in Lower Limb Biomechanics
Background/Objectives: Quasi-static inverse dynamics is widely used in biomechanical analyses due to its computational simplicity; however, neglecting inertial effects may introduce joint-specific torque estimation errors during dynamic movements. The purpose of this study was to quantify torque estimation errors introduced by quasi-static assumptions during bodyweight squats performed at different movement frequencies. Methods: A planar MATLAB-based (version R2022a) musculoskeletal model incorporating standard anthropometric parameters was developed to simulate squat motions at 1.00, 0.75, 0.50, and 0.25 Hz. Joint torques calculated using quasi-static inverse dynamics were compared with fully dynamic inverse dynamics at the ankle, knee, and hip. Model agreement was evaluated using Root Mean Square Error (RMSE), normalized percentage error relative to peak dynamic torque, and bootstrapped 95% confidence intervals (CI). Results: Quasi-static modeling produced negligible torque estimation errors at the ankle and knee across all movement frequencies, with percentage errors consistently below 0.1% and narrow confidence intervals. In contrast, the hip joint demonstrated a clear frequency-dependent underestimation of torque when inertial effects were neglected. At 1.00 Hz, the hip RMSE reached 14.4 Nm, corresponding to 14.01% of peak dynamic torque (95% CI: 13.97–14.06%). Error magnitude increased systematically with movement speed. Conclusions: The validity of quasi-static inverse dynamics strongly depends on joint location and movement frequency. While quasi-static models are appropriate for ankle and knee torque estimation during moderate-speed squats, accurate hip torque assessment during faster squats requires full dynamic modeling. These findings provide quantitative benchmarks to inform model selection in biomechanical research, rehabilitation engineering, and assistive device design.
- Open Access
- 25 December 2025
- Published by International Advanced Researches and Engineering Journal in International Advanced Researches and Engineering Journal
- Vol. 9 (3) , 191-200
Investigation of backlash and friction nonlinearities in a 1-DoF electromechanical system based on experimental data
The characterization of nonlinearities, specifically backlash and friction, in one-degree-of-freedom (1-DoF) electromechanical systems is essential for achieving high-precision control. This study presents a systematic investigation into the identification of these phenomena using a white-box modeling approach. An experimental platform, consisting of a brushed DC motor with a gearbox and a 3D-printed L-shaped load arm, was developed to generate input-output data from sinusoidal voltage excitations. A comprehensive nonlinear model, developed in MATLAB/Simulink, incorporated electrical dynamics, Coulomb and viscous friction, gravitational torque, and backlash dead-zone effects. Two complementary parameter identification methods, Nonlinear Least Squares Errors (NLSE) estimation and a Genetic Algorithm (GA), were applied to estimate the model's unknown parameters. Results demonstrated that both approaches successfully captured the dominant system dynamics; however, NLSE achieved superior accuracy in both identification (RMSE = 0.13 rad/s, R2 = 0.99) and verification (RMSE = 0.16 rad/s, R2 = 0.96) phases, compared to GA (RMSE = 0.21-0.22 rad/s, R2 = 0.94-0.97). These findings demonstrate that, with identical initialization and constraints of system parameters, a physics-based white-box model combined with NLSE provides a more reliable and precise characterization of combined backlash and friction nonlinearities than GA for the investigated 1-DoF electromechanical system and excitation conditions.
- 25 December 2025
- Published by International Advanced Researches and Engineering Journal in International Advanced Researches and Engineering Journal
- Vol. 9 (3) , 191-200
Open AccessInvestigation of backlash and friction nonlinearities in a 1-DoF electromechanical system based on experimental data
The characterization of nonlinearities, specifically backlash and friction, in one-degree-of-freedom (1-DoF) electromechanical systems is essential for achieving high-precision control. This study presents a systematic investigation into the identification of these phenomena using a white-box modeling approach. An experimental platform, consisting of a brushed DC motor with a gearbox and a 3D-printed L-shaped load arm, was developed to generate input-output data from sinusoidal voltage excitations. A comprehensive nonlinear model, developed in MATLAB/Simulink, incorporated electrical dynamics, Coulomb and viscous friction, gravitational torque, and backlash dead-zone effects. Two complementary parameter identification methods, Nonlinear Least Squares Errors (NLSE) estimation and a Genetic Algorithm (GA), were applied to estimate the model's unknown parameters. Results demonstrated that both approaches successfully captured the dominant system dynamics; however, NLSE achieved superior accuracy in both identification (RMSE = 0.13 rad/s, R2 = 0.99) and verification (RMSE = 0.16 rad/s, R2 = 0.96) phases, compared to GA (RMSE = 0.21-0.22 rad/s, R2 = 0.94-0.97). These findings demonstrate that, with identical initialization and constraints of system parameters, a physics-based white-box model combined with NLSE provides a more reliable and precise characterization of combined backlash and friction nonlinearities than GA for the investigated 1-DoF electromechanical system and excitation conditions.
- Open Access
- 2 October 2024
- Published by The Open Journal in Journal of Open Source Software
- Vol. 9 (102) , 6842
KielMAT: Kiel Motion Analysis Toolbox - An Open-Source Python Toolbox for Analyzing Neurological Motion Data from Various Recording Modalities
The Kiel Motion Analysis Toolbox (KielMAT) is an open-source Python-based toolbox designed for processing human motion data, following open-science practices. KielMAT offers a range of algorithms for the processing of motion data in neuroscience and biomechanics and currently includes implementations for gait sequence detection, initial contact detection, physical activity monitoring, sit to stand and stand to sit detection algorithms. These algorithms aid in identifying patterns in human motion data on different time scales. The KielMAT is versatile in accepting motion data from various recording modalities, including IMUs that provide acceleration data from specific body locations such as the pelvis or wrist. This flexibility allows researchers to analyze data captured using different hardware setups, ensuring broad applicability across studies. Some of the toolbox algorithms have been developed and validated in clinical cohorts, allowing extracted patters to be used in a clinical context. The modular design of KielMAT allows the toolbox to be easily extended to incorporate relevant algorithms which will be developed in the research community. The toolbox is designed to be user-friendly and is accompanied by a comprehensive documentation and practical examples, while the underlying data structures build on the Motion BIDS specification (Jeung et al., 2024). The KielMAT toolbox is intended to be used by researchers and clinicians to analyze human motion data from various recording modalities and to promote the utilization of open-source software in the field of human motion analysis.
- 2 October 2024
- Published by The Open Journal in Journal of Open Source Software
- Vol. 9 (102) , 6842
Open AccessKielMAT: Kiel Motion Analysis Toolbox - An Open-Source Python Toolbox for Analyzing Neurological Motion Data from Various Recording Modalities
The Kiel Motion Analysis Toolbox (KielMAT) is an open-source Python-based toolbox designed for processing human motion data, following open-science practices. KielMAT offers a range of algorithms for the processing of motion data in neuroscience and biomechanics and currently includes implementations for gait sequence detection, initial contact detection, physical activity monitoring, sit to stand and stand to sit detection algorithms. These algorithms aid in identifying patterns in human motion data on different time scales. The KielMAT is versatile in accepting motion data from various recording modalities, including IMUs that provide acceleration data from specific body locations such as the pelvis or wrist. This flexibility allows researchers to analyze data captured using different hardware setups, ensuring broad applicability across studies. Some of the toolbox algorithms have been developed and validated in clinical cohorts, allowing extracted patters to be used in a clinical context. The modular design of KielMAT allows the toolbox to be easily extended to incorporate relevant algorithms which will be developed in the research community. The toolbox is designed to be user-friendly and is accompanied by a comprehensive documentation and practical examples, while the underlying data structures build on the Motion BIDS specification (Jeung et al., 2024). The KielMAT toolbox is intended to be used by researchers and clinicians to analyze human motion data from various recording modalities and to promote the utilization of open-source software in the field of human motion analysis.
- Open Access
- 28 September 2023
- Published by Elsevier in Computational Materials Science
- Vol. 230
System identification and artificial intelligent (AI) modelling of the molten salt electrolysis process for prediction of the anode effect
- 28 September 2023
- Published by Elsevier in Computational Materials Science
- Vol. 230
Open AccessSystem identification and artificial intelligent (AI) modelling of the molten salt electrolysis process for prediction of the anode effect
- Open Access
- 23 December 2022
- Published by Cambridge University Press (CUP) in Robotica
- Vol. 41 (4) , 1348-1370
Nonlinear model identification and statistical verification using experimental data with a case study of the UR5 manipulator joint parameters
The identification of nonlinear terms existing in the dynamic model of real-world mechanical systems such as robotic manipulators is a challenging modeling problem. The main aim of this research is not only to identify the unknown parameters of the nonlinear terms but also to verify their existence in the model. Generally, if the structure of the model is provided, the parameters of the nonlinear terms can be identified using different numerical approaches or evolutionary algorithms. However, finding a non-zero coefficient does not guarantee the existence of the nonlinear term or vice versa. Therefore, in this study, a meticulous investigation and statistical verification are carried out to ensure the reliability of the identification process. First, the simulation data are generated using the white-box model of a direct current motor that includes some of the nonlinear terms. Second, the particle swarm optimization (PSO) algorithm is applied to identify the unknown parameters of the model among many possible configurations. Then, to evaluate the results of the algorithm, statistical hypothesis and confidence interval tests are implemented. Finally, the reliability of the PSO algorithm is investigated using experimental data acquired from the UR5 manipulator. To compare the results of the PSO algorithm, the nonlinear least squares errors (NLSE) estimation algorithm is applied to identify the unknown parameters of the nonlinear models. The result shows that the PSO algorithm has higher identification accuracy than the NLSE estimation algorithm, and the model with identified parameters using the PSO algorithm accurately calculates the output torques of the joints of the manipulator.
- 23 December 2022
- Published by Cambridge University Press (CUP) in Robotica
- Vol. 41 (4) , 1348-1370
Open AccessNonlinear model identification and statistical verification using experimental data with a case study of the UR5 manipulator joint parameters
The identification of nonlinear terms existing in the dynamic model of real-world mechanical systems such as robotic manipulators is a challenging modeling problem. The main aim of this research is not only to identify the unknown parameters of the nonlinear terms but also to verify their existence in the model. Generally, if the structure of the model is provided, the parameters of the nonlinear terms can be identified using different numerical approaches or evolutionary algorithms. However, finding a non-zero coefficient does not guarantee the existence of the nonlinear term or vice versa. Therefore, in this study, a meticulous investigation and statistical verification are carried out to ensure the reliability of the identification process. First, the simulation data are generated using the white-box model of a direct current motor that includes some of the nonlinear terms. Second, the particle swarm optimization (PSO) algorithm is applied to identify the unknown parameters of the model among many possible configurations. Then, to evaluate the results of the algorithm, statistical hypothesis and confidence interval tests are implemented. Finally, the reliability of the PSO algorithm is investigated using experimental data acquired from the UR5 manipulator. To compare the results of the PSO algorithm, the nonlinear least squares errors (NLSE) estimation algorithm is applied to identify the unknown parameters of the nonlinear models. The result shows that the PSO algorithm has higher identification accuracy than the NLSE estimation algorithm, and the model with identified parameters using the PSO algorithm accurately calculates the output torques of the joints of the manipulator.
- Open Access
- 10 November 2022
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 14 (11)
Design optimization of a solenoid actuator using particle swarm optimization algorithm with multiple objectives
Solenoid actuators are well-known components that convert electromagnetic energy into mechanical energy. For control purposes, it is requested to have a high magnetic force that stays almost constant in the working region of the actuator. To meet these requirements, it is necessary to have an optimal geometrical design of the actuator. In this study, the following steps are performed to optimize the geometry of the solenoid actuator. The Finite Element Analysis (FEA) is performed, and the results of the simulation is verified with the experimental data. The effect of all geometrical parameters on the characteristics of the magnetic force is investigated. The parameters that highly affect the magnetic force are chosen as design optimization parameters. Then, the Particle Swarm Optimization (PSO) algorithm is realized to find optimal parameters. The algorithm consists of two objective functions being combined into a single objective function. It includes a higher and more consistent magnetic force in the effective working region of the solenoid. Finally, the solenoid actuator with optimized parameters is manufactured, and the results are compared. They show that the optimized solenoid actuator satisfies one of the objective functions, and magnetic force stays almost constant in the working region of the solenoid actuator.
- 10 November 2022
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 14 (11)
Open AccessDesign optimization of a solenoid actuator using particle swarm optimization algorithm with multiple objectives
Solenoid actuators are well-known components that convert electromagnetic energy into mechanical energy. For control purposes, it is requested to have a high magnetic force that stays almost constant in the working region of the actuator. To meet these requirements, it is necessary to have an optimal geometrical design of the actuator. In this study, the following steps are performed to optimize the geometry of the solenoid actuator. The Finite Element Analysis (FEA) is performed, and the results of the simulation is verified with the experimental data. The effect of all geometrical parameters on the characteristics of the magnetic force is investigated. The parameters that highly affect the magnetic force are chosen as design optimization parameters. Then, the Particle Swarm Optimization (PSO) algorithm is realized to find optimal parameters. The algorithm consists of two objective functions being combined into a single objective function. It includes a higher and more consistent magnetic force in the effective working region of the solenoid. Finally, the solenoid actuator with optimized parameters is manufactured, and the results are compared. They show that the optimized solenoid actuator satisfies one of the objective functions, and magnetic force stays almost constant in the working region of the solenoid actuator.