TXTao Xing

Tao Xing

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tao Xing has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Digital-twin and data-driven absolute aspheric interferometry by multi-wavefronts transformer networks

    by Tao Xing, Xiangyang Liu, Jing Wang, Hangkai Pan, Leling Jin, Jinming Gao, Shouli Sun, Yinxu Bian, Cuifang Kuang, Xu Liu


  • Intelligent Interferometric Measurement for Aspheric Surfaces via Attention-CNN

    by Hangkai Pan, Tao Xing, Leling Jin, Jinming Gao, Shouli Sun, Yinxu Bian, Cuifang Kuang, Xu Liu

    The measurement of aspheric surfaces faces significant challenges in both accuracy and efficiency. When measuring, it is difficult to align the computer-generated hologram (CGH) and the aspheric surface. The alignment and measurement require the engineers and researchers with high proficiency and expertise of the optical measurement. Automatic interferometric measurement can improve and promote the accuracy, efficiency and applications. In this work, an automatic interferometric measurement based on deep learning is proposed to enhance the measurement of aspheric surfaces. By building a mapping model between wavefront aberrations and surface misalignments, the system can be automatically aligned, enabling high-precision automated measurements without excessive manual intervention. Experimental and simulation results demonstrate that the proposed Attention-Convolutional Neural Network (Attention-CNN) can achieve the accuracy of 0.5 μm in decenter and 0.2 " (arcseconds) in tilt, with the misalignment error confined to less than 2 nm root mean square (RMS). Furthermore, the repeatability of surface figure measurements, calculated as twice the standard deviation from repeated measurements, is 2.64 nm RMS. These findings indicate that the proposed method offers exceptional performance in terms of both measurement accuracy and efficiency.


  • Open Access

    Computational Portable Microscopes for Point-of-Care-Test and Tele-Diagnosis

    by Yinxu Bian, Tao Xing, Kerong Jiao, Qingqing Kong, Jiaxiong Wang, Xiaofei Yang, Shenmin Yang, Yannan Jiang, Renbing Shen, Hua Shen, et al.

    In bio-medical mobile workstations, e.g., the prevention of epidemic viruses/bacteria, outdoor field medical treatment and bio-chemical pollution monitoring, the conventional bench-top microscopic imaging equipment is limited. The comprehensive multi-mode (bright/dark field imaging, fluorescence excitation imaging, polarized light imaging, and differential interference microscopy imaging, etc.) biomedical microscopy imaging systems are generally large in size and expensive. They also require professional operation, which means high labor-cost, money-cost and time-cost. These characteristics prevent them from being applied in bio-medical mobile workstations. The bio-medical mobile workstations need microscopy systems which are inexpensive and able to handle fast, timely and large-scale deployment. The development of lightweight, low-cost and portable microscopic imaging devices can meet these demands. Presently, for the increasing needs of point-of-care-test and tele-diagnosis, high-performance computational portable microscopes are widely developed. Bluetooth modules, WLAN modules and 3G/4G/5G modules generally feature very small sizes and low prices. And industrial imaging lens, microscopy objective lens, and CMOS/CCD photoelectric image sensors are also available in small sizes and at low prices. Here we review and discuss these typical computational, portable and low-cost microscopes by refined specifications and schematics, from the aspect of optics, electronic, algorithms principle and typical bio-medical applications.