WCWenya Chen

Wenya Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wenya Chen has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Dual-beamline electro-optic continuous focal zooming for KrF laser drivers

    by Qijun Chen, WenYa Chen, Bin Zhang, Zheqiang Zhong

    Focal zooming is a critical technique for direct-drive inertial confinement fusion (ICF). In this paper, we propose a dual-beamline electro-optic (EO) continuous focal-zooming scheme for KrF laser drivers, capable of delivering nanosecond-scale response and continuously tunable focal-spot diameters over a wide range. In each beamline, wavefront modulation by an EO crystal enables continuous variation of the focal-spot diameter, while switching between the two beamlines extends the overall zooming range beyond the capability of a single element. Numerical simulations demonstrate that the proposed scheme achieves an approximately threefold continuous spot compression while maintaining a well-defined flat-top focal profile and excellent irradiation uniformity within 1% root-mean-square (RMS) nonuniformity. This work provides a viable approach for dynamic irradiation control and enhanced laser–target coupling in high-power KrF laser drivers.

  • Vanadium dioxide and a graphene-based ultra-wideband absorption and polarization conversion switchable terahertz device

    by Wenya Chen, Chao Li, Dong Wang, Song Gao, Guozheng Wu, Shijing Guo, Jiaran Xiong

    A multifunctional terahertz functional device based on vanadium dioxide (VO2) and graphene is proposed, which can realize ultra-wideband absorption and polarization conversion. When the VO2 is in the insulating state, the device can achieve the polarization conversion function to convert the incident wave into the corresponding cross-polarized wave. Polarization conversion ratios (PCRs) can exceed 90% in the 2.1–8 THz frequency range; in the 3–7.5 THz range, the PCR can be more than 95%. When VO2 is in the metallic state and the graphene Fermi energy is 0.9 eV, the device can realize a broadband absorption function. An absorption rate of more than 90% can be achieved over a wide frequency range of 3.3–7.7 THz. In addition, the polarization conversion device can maintain high performance in broadband polarization conversion at incident angles no greater than 40°. The absorber device also exhibits insensitivity to both incident and polarization angles. These advantages which make the proposed multifunctional terahertz functional device have a wide range of applications in the fields of terahertz imaging, sensing, communication, and so on.


  • Tunable terahertz polarization conversion and absorption devices based on metamaterials

    by Wenya Chen, Chao Li, Dong Wang, Song Gao, Guozheng Wu, Shijing Guo, Jiaran Xiong

    Metamaterials, as novel materials, have electromagnetic behaviors that can be realized by rationally designing the unit structure. It plays an important role in the research of terahertz functional devices. Switchable terahertz devices are constructed by flexibly combining the excellent properties of graphene and vanadium dioxide (VO2) with the application potential of terahertz technology. When the VO2 is in the metallic state and the graphene Fermi energy level is 0 eV, the device behaves as a broadband polarization switching device. It can realize cross-polarization conversion for the incident electromagnetic wave in the range of 2–4.2 THz. When the VO2 is in the insulating state and the graphene Fermi energy level is 0.9 eV, the device is an absorption device. The absorption rate can reach more than 99% at 4 THz. In addition, the polarization conversion ratio (PCR) as well as the absorption rate of the device can be tuned independently. This actively tunable switchable terahertz device provides ideas for dynamically controlling terahertz, bringing more possibilities for various applications such as terahertz imaging, stealth, and communication.


  • Dual-band terahertz metamaterial sensor and its sensing capacity enhanced with a central-relief design

    by Shijing Guo, Chao Li, Dong Wang, Wenya Chen, Song Gao, Guozheng Wu, Jiaran Xiong

    In this paper, a dual-band terahertz metamaterial sensor based on aluminum and silicon is proposed and simulated. The aluminum surface, which is deposited on a silicon substrate, is made of a C-shaped frame resonator, a rectangular beam, and a cross. The device is insensitive to the change of incident angle in the range of 0°–30°, which shows the great transmission stability of the sensor. By examining the resonance frequency shift, it is shown that 98.3 and 237.5 GHz/RIU refractive index sensitivity can be obtained near 1.76 and 2.404 THz transmission dips of the proposed structure, respectively. The two dips can be used to sense analytes in different refractive index ranges, respectively. For Dip 1 at 1.76 THz, the range is 1.0–1.6. For Dip 2 at 2.404 THz, the range is 1.6–2.0. Different from traditional multi-band metamaterial sensors, two dips generated by the proposed device can measure continuous and non-multiplexed refractive index ranges, respectively. Because the resonance frequencies of matters are different, such a characteristic enables the device to measure different types of analyte using the appropriate resonant peak. A central-relief design is then proposed based on perturbation theory to further improve its sensing performance. The aluminum cross is covered by polyimide, which can interfere with the scattering field on the metal surface and affect the transmission results. For both transmission dips, the optimized structure realizes higher sensitivities of 111.7 GHz/RIU and 262.5 GHz/RIU, respectively. More significantly, the optimized structure also has the characteristic of a wide and non-multiplexed refractive index range. In addition, the effects of analyte thickness and polyimide layer thickness on sensor performance are also discussed. The proposed structure opens up new prospects in the design of multiple-band terahertz metamaterial sensors. It can also meet the sensing needs of biomedical, environmental monitoring, and industrial manufacturing.


  • Vanadium dioxide-based ultra-broadband metamaterial absorber for terahertz waves

    by Guozheng Wu, Chao Li, Dong Wang, Song Gao, Wenya Chen, Shijing Guo, Jiaran Xiong


  • Open Access

    Flat Photonic Crystal Fiber Plasmonic Sensor for Simultaneous Measurement of Temperature and Refractive Index with High Sensitivity

    by Wei An, Chao Li, Dong Wang, Wenya Chen, Shijing Guo, Song Gao, Chunwei Zhang

    A compact temperature-refractive index (RI) flat photonic crystal fiber (PCF) sensor based on surface plasmon resonance (SPR) is presented in this paper. Sensing of temperature and RI takes place in the x- and y- polarization, respectively, to avoid the sensing crossover, eliminating the need for matrix calculation. Simultaneous detection of dual parameters can be implemented by monitoring the loss spectrum of core modes in two polarizations. Compared with the reported multi-function sensors, the designed PCF sensor provides higher sensitivities for both RI and temperature detection. A maximum wavelength sensitivity of −5 nm/°C is achieved in the temperature range of −30–40 °C. An excellent optimal wavelength sensitivity of 17,000 nm/RIU is accomplished in the RI range of 1.32–1.41. The best amplitude sensitivity of RI is up to 354.39 RIU−1. The resolution of RI and temperature sensing is 5.88 × 10−6 RIU and 0.02 °C, respectively. The highest value of the figure of merit (FOM) is 216.74 RIU−1. In addition, the flat polishing area of the gold layer reduces the manufacturing difficulty. The proposed sensor has the characteristics of high sensitivity, simple structure, good fabrication repeatability, and flexible operation. It has potential in medical diagnosis, chemical inspection, and many other fields.


  • Tunable wideband-narrowband switchable absorber based on vanadium dioxide and graphene

    by Wenya Chen, Chao Li, Dong Wang, Wei An, Song Gao, Chunwei Zhang, Shijing Guo

    A functionally tunable and absorption-tunable terahertz (THz) metamaterial absorber based on vanadium dioxide (VO2) and graphene is proposed and verified numerically. Based on phase transition properties of VO2 and tunability of graphene, the switching performance between ultra-broadband and narrow-band near-perfect absorption can be achieved. We simulate and analyze the characteristics of the constructed model by finite element analysis. Theoretical calculations show that when VO2 is in the metallic state and the graphene Fermi energy is 0 eV, the designed absorber can perform ultra-broadband absorption. The absorber achieves greater than 95% absorption in the 2.85 - 10THz range. When VO2 is in the insulating state and the graphene Fermi energy is 0.7 eV, more than 99.5% absorption can be achieved at 2.3 THz. The absorption rate can be tuned by changing the conductivity of VO2 and the Fermi energy of graphene. Moreover, the proposed absorber displays good polarization insensitivity and wide incident angle stability. The design may have potential applications in terahertz imaging, sensing, electromagnetic shielding and so on.


  • Deep Learning for Automatic Upper Airway Obstruction Detection by Analysis of Flow-Volume Curve

    by Yimin Wang, Yicong Li, Wenya Chen, Changzheng Zhang, Lijuan Liang, Ruibo Huang, Wenhua Jian, Jianling Liang, Senhua Zhu, Dandan Tu, et al.

    Background: Due to the similar symptoms of upper airway obstruction to asthma, misdiagnosis is common. Spirometry is a cost-effective screening test for upper airway obstruction and its characteristic patterns involving fixed, variable intrathoracic and extrathoracic lesions. We aimed to develop a deep learning model to detect upper airway obstruction patterns and compared its performance with that of lung function clinicians. Methods: Spirometry records were reviewed to detect the possible condition of airway stenosis. Then they were confirmed by the gold standard (e.g., computed tomography, endoscopy, or clinic diagnosis of upper airway obstruction). Images and indices derived from flow-volume curves were used for training and testing the model. Clinicians determined cases using spirometry records from the test set. The deep learning model evaluated the same data. Results: Of 45,831 patients’ spirometry records, 564 subjects with curves suggesting upper airway obstruction, after verified by the gold standard, 351 patients were confirmed. These cases and another 200 cases without airway stenosis were used as the training and testing sets. 432 clinicians evaluated 20 cases of each of the three patterns and 20 no airway stenosis cases (n = 80). They assigned an accuracy of 41.2% (±15.4) (interquartile range: 27.5–52.5%), with poor agreements (κ = 0.12). For the same cases, the model generated a correct detection of 81.3% (p < 0.0001). Conclusions: Deep learning could detect upper airway obstruction patterns from other classic patterns of ventilatory defects with high accuracy, whereas clinicians presented marked errors and variabilities. The model may serve as a support tool to enhance clinicians’ correct diagnosis of upper airway obstruction using spirometry.