Arianna Winchester
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Arianna Winchester has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Daniel Jethanamest
New York University Grossman School of Medicine
4 shared publicationsEmily Kay-Rivest
Department of Otolaryngology–Head and Neck Surgery, New York University Grossman School of Medicine, New York, New York
3 shared publicationsGul Moonis
Department of Radiology, New York University Grossman School of Medicine, New York, New York
2 shared publicationsJustin Cottrell
Yale New Haven Health
2 shared publicationsMari Hagiwara
Department of Radiology, New York University Grossman School of Medicine, New York, New York
2 shared publicationsMary Bruno
Department of Radiology, New York University Grossman School of Medicine, New York, New York
2 shared publications
Latest Publications
- 14 April 2026
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 140 (6) , 1-8
Anticoagulation and antiplatelet therapy in endoscopic ear surgery
Objectives: Assess the impact of anticoagulation or antiplatelet medications on endoscopic ear surgery visibility and procedural progress. Methods: A case–control retrospective chart review of patients on anticoagulation/antiplatelet undergoing endoscopic ear surgery from April 2018 to April 2023 was conducted. Surgical videos were blindly rated by two surgeons utilising the Modena Bleeding Scale during clips of key operative steps; scores and outcomes were compared. Equivalence analysis was performed using two one-sided tests with an equivalence range of plus-or-minus 0.4 Modena Bleeding Scale points. Results: Fourteen cases were matched with 28 controls. Cases were more male (85.7 per cent; p < 0.01) and older (median: 54.9 years) than controls (median: 37.8; p < 0.01). Eleven cases (78.6 per cent) were on aspirin 81 mg, two (14.2 per cent) coumadin (4–6 mg) and one (7.1 per cent) aspirin 325 mg. No significant differences in Modena Bleeding Scale, blood loss, complications or outcomes were found. Conclusion: This study revealed no significant difference in intra-operative visibility, progress, complications or outcomes with patients on anticoagulation/antiplatelet. Endoscopic ear surgery may be considered while on anticoagulation/antiplatelet.
- 14 April 2026
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 140 (6) , 1-8
Anticoagulation and antiplatelet therapy in endoscopic ear surgery
Objectives: Assess the impact of anticoagulation or antiplatelet medications on endoscopic ear surgery visibility and procedural progress. Methods: A case–control retrospective chart review of patients on anticoagulation/antiplatelet undergoing endoscopic ear surgery from April 2018 to April 2023 was conducted. Surgical videos were blindly rated by two surgeons utilising the Modena Bleeding Scale during clips of key operative steps; scores and outcomes were compared. Equivalence analysis was performed using two one-sided tests with an equivalence range of plus-or-minus 0.4 Modena Bleeding Scale points. Results: Fourteen cases were matched with 28 controls. Cases were more male (85.7 per cent; p < 0.01) and older (median: 54.9 years) than controls (median: 37.8; p < 0.01). Eleven cases (78.6 per cent) were on aspirin 81 mg, two (14.2 per cent) coumadin (4–6 mg) and one (7.1 per cent) aspirin 325 mg. No significant differences in Modena Bleeding Scale, blood loss, complications or outcomes were found. Conclusion: This study revealed no significant difference in intra-operative visibility, progress, complications or outcomes with patients on anticoagulation/antiplatelet. Endoscopic ear surgery may be considered while on anticoagulation/antiplatelet.
- 1 May 2025
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 46 (6) , 641-647
Image Quality Improvement in MRI of Cochlear Implants and Auditory Brainstem Implants After Metal Artifact Reduction Techniques
Objective: Observe if metal artifact reduction (MAR) techniques applied to magnetic resonance imaging (MRI) performed on patients with cochlear implants (CI) or auditory brainstem implants (ABI) improves image quality. Study Design: Retrospective review. Setting: Tertiary care center. Patients: Patients with auditory implants who underwent clinical MRI before and after the application of MAR techniques previously described. Interventions: From September 2022 to March 2023, patients who underwent brain or internal auditory canal (IAC) MRI with and without MAR were identified. Sequences included T1 and T2 weighted with turbo-spin-echo (TSE) correction and fluid-attenuation inversion recovery (FLAIR). Images were analyzed for visualization of intracranial structures by two neuroradiologists. Main Outcome Measures: Visibility of 14 structures graded on a four-point Likert scale. Average scores per structure and sequence were compared using paired two-tailed t-tests and change in mode score. Results: Ten patients underwent pre- and post-MAR MRI. Six had a unilateral CI, three had a unilateral ABI, and one had an ABI and CI. Three patients had four devices with the internal magnet removed for both scans. All structures had significantly improved visibility on post-MAR scan except ipsilateral parietal and occipital lobes and contralateral inner ear. Mode score increased from 2 to 4 for the ipsilateral occipital lobe and from 3 to 4 for the ipsilateral semicircular canals, brainstem, and cerebellar peduncles. Significant improvement was seen in all sequences except for ipsilateral structures on T1w axial precontrast and contralateral structures on T1w coronal postcontrast. ABIs did not improve as much as CIs because they scored better on the pre-MAR scan. Conclusions: MAR techniques improve image quality for patients with MRI-compatible implants with magnets. Benefits may be more evident in CIs than ABIs.
- 1 May 2025
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 46 (6) , 641-647
Image Quality Improvement in MRI of Cochlear Implants and Auditory Brainstem Implants After Metal Artifact Reduction Techniques
Objective: Observe if metal artifact reduction (MAR) techniques applied to magnetic resonance imaging (MRI) performed on patients with cochlear implants (CI) or auditory brainstem implants (ABI) improves image quality. Study Design: Retrospective review. Setting: Tertiary care center. Patients: Patients with auditory implants who underwent clinical MRI before and after the application of MAR techniques previously described. Interventions: From September 2022 to March 2023, patients who underwent brain or internal auditory canal (IAC) MRI with and without MAR were identified. Sequences included T1 and T2 weighted with turbo-spin-echo (TSE) correction and fluid-attenuation inversion recovery (FLAIR). Images were analyzed for visualization of intracranial structures by two neuroradiologists. Main Outcome Measures: Visibility of 14 structures graded on a four-point Likert scale. Average scores per structure and sequence were compared using paired two-tailed t-tests and change in mode score. Results: Ten patients underwent pre- and post-MAR MRI. Six had a unilateral CI, three had a unilateral ABI, and one had an ABI and CI. Three patients had four devices with the internal magnet removed for both scans. All structures had significantly improved visibility on post-MAR scan except ipsilateral parietal and occipital lobes and contralateral inner ear. Mode score increased from 2 to 4 for the ipsilateral occipital lobe and from 3 to 4 for the ipsilateral semicircular canals, brainstem, and cerebellar peduncles. Significant improvement was seen in all sequences except for ipsilateral structures on T1w axial precontrast and contralateral structures on T1w coronal postcontrast. ABIs did not improve as much as CIs because they scored better on the pre-MAR scan. Conclusions: MAR techniques improve image quality for patients with MRI-compatible implants with magnets. Benefits may be more evident in CIs than ABIs.
- 14 April 2025
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 173 (1) , 49-57
Microtia Reconstruction Practices Among Otolaryngologists in the United States
Objective: This study aims to describe current practices among otolaryngology‐trained microtia surgeons in the United States.Study Design: Survey.Setting: A tertiary care center.Methods: A 22‐question anonymous digital survey of practice patterns and surgical methods was distributed to all members of the American Academy of Facial Plastic and Reconstructive Surgery (AAFPRS) and the American Society of Pediatric Otolaryngology (ASPO). Responses were analyzed using descriptive statistics and linear regression models.Results: Of 1730 eligible members, 83 (4.8%) responses were collected. Forty‐three (51.8%) were AAFPRS members, 39 (47.0%) were ASPO members, and 1 (1.2%) reported dual membership. Respondents had multiple practice settings, were at different stages in their experience, and were well‐distributed geographically. Forty (48.2%) don't perform microtia repair and half (52.5%) refer to an FPRS‐trained colleague. Among microtia surgeons, most (N = 30, 69.8%) received fellowship training. Autologous reconstruction was the most popular method for training and practice; however, most perform multiple methods (N = 33, 76.7%). Autologous rib training was positively correlated with experience of >20 years. Those with combined autologous/alloplastic practice were more frequently trained by PO fellowship. Surgical site infection was the most frequent complication and was seen more often by those trained via residency alone (OR 12.8, P < .05). Those who trained in autologous rib alone were less likely to encounter postoperative graft exposure (OR 5.0, P < .05); however, they were more likely to encounter skin and soft tissue infection (OR 0.07, P < .05).Conclusion: Otolaryngology‐trained microtia surgeons come from a variety of academic backgrounds and progress to varied practices. They are trained and practice both alloplastic and autologous repair methods, although autologous methods remain the most common.
- 14 April 2025
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 173 (1) , 49-57
Microtia Reconstruction Practices Among Otolaryngologists in the United States
Objective: This study aims to describe current practices among otolaryngology‐trained microtia surgeons in the United States.Study Design: Survey.Setting: A tertiary care center.Methods: A 22‐question anonymous digital survey of practice patterns and surgical methods was distributed to all members of the American Academy of Facial Plastic and Reconstructive Surgery (AAFPRS) and the American Society of Pediatric Otolaryngology (ASPO). Responses were analyzed using descriptive statistics and linear regression models.Results: Of 1730 eligible members, 83 (4.8%) responses were collected. Forty‐three (51.8%) were AAFPRS members, 39 (47.0%) were ASPO members, and 1 (1.2%) reported dual membership. Respondents had multiple practice settings, were at different stages in their experience, and were well‐distributed geographically. Forty (48.2%) don't perform microtia repair and half (52.5%) refer to an FPRS‐trained colleague. Among microtia surgeons, most (N = 30, 69.8%) received fellowship training. Autologous reconstruction was the most popular method for training and practice; however, most perform multiple methods (N = 33, 76.7%). Autologous rib training was positively correlated with experience of >20 years. Those with combined autologous/alloplastic practice were more frequently trained by PO fellowship. Surgical site infection was the most frequent complication and was seen more often by those trained via residency alone (OR 12.8, P < .05). Those who trained in autologous rib alone were less likely to encounter postoperative graft exposure (OR 5.0, P < .05); however, they were more likely to encounter skin and soft tissue infection (OR 0.07, P < .05).Conclusion: Otolaryngology‐trained microtia surgeons come from a variety of academic backgrounds and progress to varied practices. They are trained and practice both alloplastic and autologous repair methods, although autologous methods remain the most common.
- 3 October 2024
- Published by Wiley in Head & Neck
- Vol. 47 (2) , 635-639
Benefits of Bedside Open Tracheostomy: A Safe and Cost‐Effective Alternative to the Operating Room
Introduction: Tracheostomy is a commonly performed procedure in Otolaryngology and can be performed in different settings. We evaluate patient characteristics and cost efficacy of tracheostomy at the bedside versus operating room (OR).Materials and Methods: Retrospective chart review was performed for adult intensive care unit (ICU) patients who underwent tracheostomy from 2020 to 2023. Data and cost of procedures were analyzed using descriptive statistics.Results: One hundred and sixty‐five patients were included. One hundred and thirty‐four (81.2%) patients underwent bedside tracheostomy. Age, sex, and BMI were not significantly different. Average time from consult to procedure and operative time was significantly shorter (p = 0.03; 0.008). There were no differences in postoperative complications, 30‐day mortality, ICU length of stay (LOS), or overall LOS. Tracheostomy at the bedside offered a 73.1% cost reduction compared with performed in the OR.Conclusion: Advantages of bedside tracheostomy include decreased operative time, time from consult to procedure, and cost reduction for the hospital system. We advocate for consideration of bedside tracheostomy when appropriate.Level of Evidence: 4.
- 3 October 2024
- Published by Wiley in Head & Neck
- Vol. 47 (2) , 635-639
Benefits of Bedside Open Tracheostomy: A Safe and Cost‐Effective Alternative to the Operating Room
Introduction: Tracheostomy is a commonly performed procedure in Otolaryngology and can be performed in different settings. We evaluate patient characteristics and cost efficacy of tracheostomy at the bedside versus operating room (OR).Materials and Methods: Retrospective chart review was performed for adult intensive care unit (ICU) patients who underwent tracheostomy from 2020 to 2023. Data and cost of procedures were analyzed using descriptive statistics.Results: One hundred and sixty‐five patients were included. One hundred and thirty‐four (81.2%) patients underwent bedside tracheostomy. Age, sex, and BMI were not significantly different. Average time from consult to procedure and operative time was significantly shorter (p = 0.03; 0.008). There were no differences in postoperative complications, 30‐day mortality, ICU length of stay (LOS), or overall LOS. Tracheostomy at the bedside offered a 73.1% cost reduction compared with performed in the OR.Conclusion: Advantages of bedside tracheostomy include decreased operative time, time from consult to procedure, and cost reduction for the hospital system. We advocate for consideration of bedside tracheostomy when appropriate.Level of Evidence: 4.
- Open Access
- 4 August 2024
- Published by Taylor & Francis in Medical Education Online
- Vol. 29 (1) , 2385666
Voices of the accelerated: key themes when considering implementation of an accelerated medical school program
In this rapid communication, accelerated undergraduate medical education is examined using prior literature as well as experiences of those who have completed or are in the process of completing accelerated medical curricula. The Consortium of Accelerated Medical Pathway Programs (CAMPP) hosts an annual multi-institutional conference for all its members. During the meeting in July 2023, a virtual panel was convened from multiple constituent programs (N = 4) including medical students (N = 2), resident physicians (N = 4), and faculty (N = 2). Panel participants represented current learners or graduates from accelerated pathways of varying specialties (N = 5) to share firsthand experiences about acceleration to an audience representing over 25 medical schools. Five key themes were identified for accelerated students and trainees: Reduced debt as motivating factor to accelerate, Feeling prepared for residency, Ideal accelerated students are driven, Ability to form early professional relationships, and Less time for additional clinical experiences. Discourse from the CAMPP panel can inform current and developing accelerated programs at institutions looking to create or improve accelerated learning.
- 4 August 2024
- Published by Taylor & Francis in Medical Education Online
- Vol. 29 (1) , 2385666
Open AccessVoices of the accelerated: key themes when considering implementation of an accelerated medical school program
In this rapid communication, accelerated undergraduate medical education is examined using prior literature as well as experiences of those who have completed or are in the process of completing accelerated medical curricula. The Consortium of Accelerated Medical Pathway Programs (CAMPP) hosts an annual multi-institutional conference for all its members. During the meeting in July 2023, a virtual panel was convened from multiple constituent programs (N = 4) including medical students (N = 2), resident physicians (N = 4), and faculty (N = 2). Panel participants represented current learners or graduates from accelerated pathways of varying specialties (N = 5) to share firsthand experiences about acceleration to an audience representing over 25 medical schools. Five key themes were identified for accelerated students and trainees: Reduced debt as motivating factor to accelerate, Feeling prepared for residency, Ideal accelerated students are driven, Ability to form early professional relationships, and Less time for additional clinical experiences. Discourse from the CAMPP panel can inform current and developing accelerated programs at institutions looking to create or improve accelerated learning.
- 5 July 2024
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 171 (6) , 1721-1727
Video Otoscopy as a Novel Teaching and Remote Otolaryngology Consultation Tool at an Academic Medical Center
Objective: Assess the use of video otoscopy (VO) as a tool for teaching Emergency Department (ED) residents and remote Otolaryngology consultation.Study Design: Survey and retrospective chart review.Setting: Tertiary care center.Methods: Emergency Medicine resident physicians completed an otologic skill self‐assessment and pathology followed by an interactive training on VO and postintervention assessment after 9 months of use. Outcomes compared change in pre‐ to posttraining scores. ED consultations using VO during this time period were reviewed to detect differences between the presumed diagnosis/treatment based only on phone consultation and VO image compared to the final diagnosis/treatment after in‐person Otolaryngology consultation.Results: Forty‐six (63.1%) ED residents participated. Diagnostic accuracy improved by 20.7% overall. The most improved diagnoses were of a normal ear canal (+75%), tympanosclerosis (+58.4%), and ear canal foreign body (+57.1%); most challenging were external auditory canal cyst (−13.6%), hemotympanum (−11.3%), and cerumen (−1.9%). Cholesteatoma did not improve because all responses were incorrect; neither did tympanic membrane perforation because all were correct. Confidence in the otologic exam and anatomy also increased (P < .01). Thirteen consults used VO and 3 (23.1%) had a change in diagnosis/treatment after in‐person Otolaryngology evaluation.Conclusion: Training on the use of VO significantly improves the confidence and diagnostic skills of ED providers for many pathologies. This application suggests the efficacy of an otologic e‐consultation model.
- 5 July 2024
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 171 (6) , 1721-1727
Video Otoscopy as a Novel Teaching and Remote Otolaryngology Consultation Tool at an Academic Medical Center
Objective: Assess the use of video otoscopy (VO) as a tool for teaching Emergency Department (ED) residents and remote Otolaryngology consultation.Study Design: Survey and retrospective chart review.Setting: Tertiary care center.Methods: Emergency Medicine resident physicians completed an otologic skill self‐assessment and pathology followed by an interactive training on VO and postintervention assessment after 9 months of use. Outcomes compared change in pre‐ to posttraining scores. ED consultations using VO during this time period were reviewed to detect differences between the presumed diagnosis/treatment based only on phone consultation and VO image compared to the final diagnosis/treatment after in‐person Otolaryngology consultation.Results: Forty‐six (63.1%) ED residents participated. Diagnostic accuracy improved by 20.7% overall. The most improved diagnoses were of a normal ear canal (+75%), tympanosclerosis (+58.4%), and ear canal foreign body (+57.1%); most challenging were external auditory canal cyst (−13.6%), hemotympanum (−11.3%), and cerumen (−1.9%). Cholesteatoma did not improve because all responses were incorrect; neither did tympanic membrane perforation because all were correct. Confidence in the otologic exam and anatomy also increased (P < .01). Thirteen consults used VO and 3 (23.1%) had a change in diagnosis/treatment after in‐person Otolaryngology evaluation.Conclusion: Training on the use of VO significantly improves the confidence and diagnostic skills of ED providers for many pathologies. This application suggests the efficacy of an otologic e‐consultation model.
- 20 February 2023
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 44 (4) , e223-e229
Image Quality and Artifact Reduction of a Cochlear Implant With Rotatable Magnets
Objective: To determine if metal reduction magnetic resonance imaging sequences and changes in implant placement minimize artifact from cochlear implants and improve visualization of intracranial structures. Study Design: Cadaveric study. Setting: Tertiary referral center. Patients: Five cadaveric heads. Interventions: Specimens were implanted with Advanced Bionics HiRes Ultra3D devices at nasion-external auditory canal angles of 90, 120, and 160 degrees, and distances from the external auditory canal of 9 or 12 cm. Standard brain/internal auditory canal (IAC) sequences with metal artifact reducing technique were acquired in a 1.5T scanner. Main Outcome Measures: The primary outcome was visibility of 14 intracranial structures graded on a 4-point scale (1, structures 50% visible with some areas nonvisible from artifact; 3, artifact present but adequate for diagnosis; and 4, high quality). Scores were determined by experienced head and neck radiologists and compared with one-way analysis of variance. Results: Imaging sequences included axial 5-mm whole-brain turbo spin echo (TSE) T2 with right to left and anterior to posterior encoding, fluid-attenuation inversion recovery high bandwidth, axial 5-mm whole-brain slice-encoding metal artifact correction (SEMAC), axial IAC constructive interference in steady state, and axial 3-mm T1 IAC with and without fat saturation. T1 IACs in axial and coronal planes were best for ipsilateral structures overall (mean [standard deviation {SD}], 3.8 [0.6] and 3.8 [0.5]). SEMAC (mean [SD], 3.5 [0.8]) was superior to TSE with anterior to posterior encoding (mean [SD], 3.5 [0.9) for ipsilateral cortex, cerebellopontine angle, and brainstem/cerebellum, and equivalent for the inner ear. Constructive interference in steady state and T1 with fat saturation were poor for all ipsilateral structures (mean, 2.8 [p < 0.01]; mean, 3.1 [p < 0.01]). The 120 degrees/12 cm position was overall best, although the 120 degrees/9 cm position still afforded visualization of ipsilateral structures; other angles and distances conferred slight advantages for specific structures of interest. Conclusions: SEMAC and T2 TSE with anterior to posterior encoding sequences provide artifact suppression while retaining excellent image quality. Different placement angles did not confer improvement in visualization, although placement distances provided slight advantages for some structures.
- 20 February 2023
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 44 (4) , e223-e229
Image Quality and Artifact Reduction of a Cochlear Implant With Rotatable Magnets
Objective: To determine if metal reduction magnetic resonance imaging sequences and changes in implant placement minimize artifact from cochlear implants and improve visualization of intracranial structures. Study Design: Cadaveric study. Setting: Tertiary referral center. Patients: Five cadaveric heads. Interventions: Specimens were implanted with Advanced Bionics HiRes Ultra3D devices at nasion-external auditory canal angles of 90, 120, and 160 degrees, and distances from the external auditory canal of 9 or 12 cm. Standard brain/internal auditory canal (IAC) sequences with metal artifact reducing technique were acquired in a 1.5T scanner. Main Outcome Measures: The primary outcome was visibility of 14 intracranial structures graded on a 4-point scale (1, structures 50% visible with some areas nonvisible from artifact; 3, artifact present but adequate for diagnosis; and 4, high quality). Scores were determined by experienced head and neck radiologists and compared with one-way analysis of variance. Results: Imaging sequences included axial 5-mm whole-brain turbo spin echo (TSE) T2 with right to left and anterior to posterior encoding, fluid-attenuation inversion recovery high bandwidth, axial 5-mm whole-brain slice-encoding metal artifact correction (SEMAC), axial IAC constructive interference in steady state, and axial 3-mm T1 IAC with and without fat saturation. T1 IACs in axial and coronal planes were best for ipsilateral structures overall (mean [standard deviation {SD}], 3.8 [0.6] and 3.8 [0.5]). SEMAC (mean [SD], 3.5 [0.8]) was superior to TSE with anterior to posterior encoding (mean [SD], 3.5 [0.9) for ipsilateral cortex, cerebellopontine angle, and brainstem/cerebellum, and equivalent for the inner ear. Constructive interference in steady state and T1 with fat saturation were poor for all ipsilateral structures (mean, 2.8 [p < 0.01]; mean, 3.1 [p < 0.01]). The 120 degrees/12 cm position was overall best, although the 120 degrees/9 cm position still afforded visualization of ipsilateral structures; other angles and distances conferred slight advantages for specific structures of interest. Conclusions: SEMAC and T2 TSE with anterior to posterior encoding sequences provide artifact suppression while retaining excellent image quality. Different placement angles did not confer improvement in visualization, although placement distances provided slight advantages for some structures.
- 21 November 2022
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 24 (2) , 87-94
HiRes ultra series cochlear implant field recall: failure rates and early outcomes
Evaluate rates of Advanced Bionics Ultra 3D/Ultra cochlear implant failure in the setting of a worldwide device recall and report surgical and auditory outcomes after revision.Retrospective chart r...
- 21 November 2022
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 24 (2) , 87-94
HiRes ultra series cochlear implant field recall: failure rates and early outcomes
Evaluate rates of Advanced Bionics Ultra 3D/Ultra cochlear implant failure in the setting of a worldwide device recall and report surgical and auditory outcomes after revision.Retrospective chart r...