Aya Essa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aya Essa has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Miharu Komori
3 shared publications- Narae Choi
Graduate School of Engineering, Osaka University, Osaka, Japan
3 shared publications - Tomohiro Kobayashi
The University of Osaka
3 shared publications - Toshio Yamanaka
Graduate School of Engineering, Osaka University, Osaka, Japan
3 shared publications Noriaki Kobayashi
2 shared publicationsTakeshi Arakawa
2 shared publications
Latest Publications
- Open Access
- 16 June 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 396, 01079
Enhancing displacement ventilation performance: Proposal of a new portable air purifying displacement ventilation unit
Displacement Ventilation (DV) has been known as an energy saving system as it relies on buoyancy force to draw hot air upwards to be displaced by cool air. The main strength of DV that recommends it nowadays is that a well-designed DV system prevents mixing of contaminants as they are dragged along the hot air upward flow leaving the occupied zone, breathing zone in particular, clean. However, the system’s effectiveness is lowered in large rooms due to design problem such as difficult balance between sufficient supply flow volume and low inlet velocity, furniture arrangement acting as obstacles, or room geometry. Hence, DV feasibility is limited to small and mid-size rooms. In order to expand the DV potential and applicability to all space types and sizes, this study proposes a portable DV air purifying unit. The unit is designed to be mobile consisting of air recycling unit with no duct connections which widens the range of use to cover a variety of indoor spaces as well as small to medium sized room. The unit has two main functions, one is reinforcing the temperature gradient as stratification crucial for DV, and the second is purifying recycled air. To investigate the effectiveness and feasibility of the proposed DV unit, block model calculations and CFD analysis were conducted. In a basic office room, multiple cases were calculated and assessed in terms of temperature distribution and stratification height. In addition, exhaled contaminants were simulated and the contaminant concentration was used as an indicator for the air quality. Observations on the proposed unit’s performance and design aspects were highlighted.
- 16 June 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 396, 01079
Open AccessEnhancing displacement ventilation performance: Proposal of a new portable air purifying displacement ventilation unit
Displacement Ventilation (DV) has been known as an energy saving system as it relies on buoyancy force to draw hot air upwards to be displaced by cool air. The main strength of DV that recommends it nowadays is that a well-designed DV system prevents mixing of contaminants as they are dragged along the hot air upward flow leaving the occupied zone, breathing zone in particular, clean. However, the system’s effectiveness is lowered in large rooms due to design problem such as difficult balance between sufficient supply flow volume and low inlet velocity, furniture arrangement acting as obstacles, or room geometry. Hence, DV feasibility is limited to small and mid-size rooms. In order to expand the DV potential and applicability to all space types and sizes, this study proposes a portable DV air purifying unit. The unit is designed to be mobile consisting of air recycling unit with no duct connections which widens the range of use to cover a variety of indoor spaces as well as small to medium sized room. The unit has two main functions, one is reinforcing the temperature gradient as stratification crucial for DV, and the second is purifying recycled air. To investigate the effectiveness and feasibility of the proposed DV unit, block model calculations and CFD analysis were conducted. In a basic office room, multiple cases were calculated and assessed in terms of temperature distribution and stratification height. In addition, exhaled contaminants were simulated and the contaminant concentration was used as an indicator for the air quality. Observations on the proposed unit’s performance and design aspects were highlighted.
- Open Access
- 16 June 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 396, 01091
Effect of distance between occupants and insulation performance of window on contaminant distribution in a room with displacement ventilation
In recent years, displacement ventilation system has received much attention in terms of infectious disease control, due to the epidemic of COVID-19 infections. Plume from occupants and the other heat sources is a very important factor for displacement ventilation because it determines the height of the contaminant stratification. Therefore, this paper aims at the effect of distance between occupants on distribution of temperature, contaminant concentration and plume from occupants in CFD analysis at first. The results suggest the specific distance where plume from occupant interfere with each other in the occupied zone. Our results also indicate that other conditions such as human body posture also affect the interference. In addition, since the aforementioned study don't take into account the influence of the temperature of window surface cooled by outside air, we vary the insulation performance of the window and check the concentration in the occupied area. The results are obtained that the amount of contaminants carried by the downward flow from the window to the lower part of the room depends on the insulation performance of the window, which affects the occupied zone.
- 16 June 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 396, 01091
Open AccessEffect of distance between occupants and insulation performance of window on contaminant distribution in a room with displacement ventilation
In recent years, displacement ventilation system has received much attention in terms of infectious disease control, due to the epidemic of COVID-19 infections. Plume from occupants and the other heat sources is a very important factor for displacement ventilation because it determines the height of the contaminant stratification. Therefore, this paper aims at the effect of distance between occupants on distribution of temperature, contaminant concentration and plume from occupants in CFD analysis at first. The results suggest the specific distance where plume from occupant interfere with each other in the occupied zone. Our results also indicate that other conditions such as human body posture also affect the interference. In addition, since the aforementioned study don't take into account the influence of the temperature of window surface cooled by outside air, we vary the insulation performance of the window and check the concentration in the occupied area. The results are obtained that the amount of contaminants carried by the downward flow from the window to the lower part of the room depends on the insulation performance of the window, which affects the occupied zone.
- Open Access
- 15 November 2022
- Published by Wiley in JAPAN ARCHITECTURAL REVIEW
- Vol. 6 (1)
Effect of source location on contaminant dispersion pattern and occupants inhaled air quality in lecture room under displacement ventilation
Displacement ventilation (DV) is considered an energy saving air conditioning system and is especially recommended for classrooms for providing cool clean air in the occupied zone. However, in the current pandemic situation, ventilation systems should be assessed in terms of infection‐spread prevention as well. Hence, this study aims at assessing the efficiency of displacement ventilation in minimizing infection spread in lecture halls through investigating the effect of source position on the contaminant concentration distribution. The settings of a mid‐size DV lecture hall in Osaka University, Japan was chosen as a case‐study. Ten single‐contaminant‐source cases were simulated using CFD software. The cases were analyzed in terms of temperature distribution, contaminant diffusion pattern and vertical distribution, and breathing air quality using indices, such as local air quality index and scale of ventilation efficiency. The results demonstrated a considerable variation between cases in terms of contaminant distribution pattern, number of occupants affected, average inhaled‐air quality, and diffusion radius. Accordingly, given the ventilation system design, best and worst case‐scenarios were pointed out and factors affecting the variation were highlighted and further investigated to conclude the impact of each factor.
- 15 November 2022
- Published by Wiley in JAPAN ARCHITECTURAL REVIEW
- Vol. 6 (1)
Open AccessEffect of source location on contaminant dispersion pattern and occupants inhaled air quality in lecture room under displacement ventilation
Displacement ventilation (DV) is considered an energy saving air conditioning system and is especially recommended for classrooms for providing cool clean air in the occupied zone. However, in the current pandemic situation, ventilation systems should be assessed in terms of infection‐spread prevention as well. Hence, this study aims at assessing the efficiency of displacement ventilation in minimizing infection spread in lecture halls through investigating the effect of source position on the contaminant concentration distribution. The settings of a mid‐size DV lecture hall in Osaka University, Japan was chosen as a case‐study. Ten single‐contaminant‐source cases were simulated using CFD software. The cases were analyzed in terms of temperature distribution, contaminant diffusion pattern and vertical distribution, and breathing air quality using indices, such as local air quality index and scale of ventilation efficiency. The results demonstrated a considerable variation between cases in terms of contaminant distribution pattern, number of occupants affected, average inhaled‐air quality, and diffusion radius. Accordingly, given the ventilation system design, best and worst case‐scenarios were pointed out and factors affecting the variation were highlighted and further investigated to conclude the impact of each factor.