Dhrubajyoti Das
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dhrubajyoti Das has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Han-Sheng Chuang
Department of Biomedical Engineering, National Cheng Kung University, Tainan, 701, Taiwan; Medical Device Innovation Center, National Cheng Kung University, Tainan, 701, Taiwan
8 shared publications - Akella Sivaramakrishna
Vellore Institute of Technology
6 shared publications N. Sivaraman
5 shared publicationsC.V.S. Brahmmananda Rao
4 shared publications- Cheng-Wen Lin
Department of Medical Laboratory Science and Biotechnology, China Medical University, Taichung 404328, Taiwan
3 shared publications Gopinadhanpillai Gopakumar
3 shared publications
Latest Publications
- 6 January 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (1) , 54-67
Realization of rapid diabetic retinopathy screening with lipocalin 1 in tear using enhanced immunofluorescence photonic crystal microchip
A portable lateral-flow microfluidic chip integrated with a photonic crystal biosensor that enhances immunofluorescence, enabling sensitive detection of diabetic retinopathy from human tear samples using lipocalin-1 as a biomarker.
- 6 January 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (1) , 54-67
Realization of rapid diabetic retinopathy screening with lipocalin 1 in tear using enhanced immunofluorescence photonic crystal microchip
A portable lateral-flow microfluidic chip integrated with a photonic crystal biosensor that enhances immunofluorescence, enabling sensitive detection of diabetic retinopathy from human tear samples using lipocalin-1 as a biomarker.
- 17 August 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1325, 343117
Rapid tear screening of diabetic retinopathy by a detachable surface acoustic wave enabled immunosensor
- 17 August 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1325, 343117
Rapid tear screening of diabetic retinopathy by a detachable surface acoustic wave enabled immunosensor
- 31 July 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1321, 343043
Detachable acoustofluidic droplet-sorter
- 31 July 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1321, 343043
Detachable acoustofluidic droplet-sorter
- 24 July 2023
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 394
Rapid particle concentration for immunofluorescence enhancement by a surface acoustic wave microchip
- 24 July 2023
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 394
Rapid particle concentration for immunofluorescence enhancement by a surface acoustic wave microchip
- Open Access
- 23 November 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (12) , 1068
LAMP-Based Point-of-Care Biosensors for Rapid Pathogen Detection
Seeking optimized infectious pathogen detection tools is of primary importance to lessen the spread of infections, allowing prompt medical attention for the infected. Among nucleic-acid-based sensing techniques, loop-mediated isothermal amplification is a promising method, as it provides rapid, sensitive, and specific detection of microbial and viral pathogens and has enormous potential to transform current point-of-care molecular diagnostics. In this review, the advances in LAMP-based point-of-care diagnostics assays developed during the past few years for rapid and sensitive detection of infectious pathogens are outlined. The numerous detection methods of LAMP-based biosensors are discussed in an end-point and real-time manner with ideal examples. We also summarize the trends in LAMP-on-a-chip modalities, such as classical microfluidic, paper-based, and digital LAMP, with their merits and limitations. Finally, we provide our opinion on the future improvement of on-chip LAMP methods. This review serves as an overview of recent breakthroughs in the LAMP approach and their potential for use in the diagnosis of existing and emerging diseases.
- 23 November 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (12) , 1068
Open AccessLAMP-Based Point-of-Care Biosensors for Rapid Pathogen Detection
Seeking optimized infectious pathogen detection tools is of primary importance to lessen the spread of infections, allowing prompt medical attention for the infected. Among nucleic-acid-based sensing techniques, loop-mediated isothermal amplification is a promising method, as it provides rapid, sensitive, and specific detection of microbial and viral pathogens and has enormous potential to transform current point-of-care molecular diagnostics. In this review, the advances in LAMP-based point-of-care diagnostics assays developed during the past few years for rapid and sensitive detection of infectious pathogens are outlined. The numerous detection methods of LAMP-based biosensors are discussed in an end-point and real-time manner with ideal examples. We also summarize the trends in LAMP-on-a-chip modalities, such as classical microfluidic, paper-based, and digital LAMP, with their merits and limitations. Finally, we provide our opinion on the future improvement of on-chip LAMP methods. This review serves as an overview of recent breakthroughs in the LAMP approach and their potential for use in the diagnosis of existing and emerging diseases.
- 20 April 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 210, 114293
Rotational diffusometric sensor with isothermal amplification for ultra-sensitive and rapid detection of SARS-CoV-2 nsp2 cDNA
- 20 April 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 210, 114293
Rotational diffusometric sensor with isothermal amplification for ultra-sensitive and rapid detection of SARS-CoV-2 nsp2 cDNA
- Open Access
- 3 March 2022
- Published by Wiley in Small Science
- Vol. 2 (5)
Ultrafast and Sensitive Screening of Pathogens by Functionalized Janus Microbeads‐Enabled Rotational Diffusometry in Combination with Isothermal Amplification
Polymerase chain reaction (PCR) is widely considered the gold standard in molecular diagnostics because of its high accuracy. However, conventional PCR is very time‐consuming (turnaround time 4–6 h), labor‐intensive, and high‐tech instruments dependent. Therefore, developing an ultrafast and sensitive nucleic amplification‐based detection method is still in high demand. Herein, a rapid screening of Escherichia coli using an advanced and sensitive biosensing method known as rotational diffusometry in combination with loop‐mediated isothermal amplification (LAMP) is reported. Given that the solution viscosity is increased with nucleic acid amplification, the viscosity change can be measured by the functionalized Janus microbeads‐enabled rotational diffusometry. The rotational diffusivity derived from capturing images of microbeads is expressed in terms of blinking signals. Under such conditions, this method can achieve a limit of detection of 42.8 fg μL−1 in 10 min for E. coli with sample volume as low as 2 μL. Additionally, detection of E. coli whole cells extracted from artificially contaminated milk, juice, and water is performed by the developed method and validated with real‐time PCR. Through this biosensing technique, a rapid, reliable, and low sample volume screening tool can be established, improving the shortcomings of the current time‐consuming and labor‐intensive methods.
- 3 March 2022
- Published by Wiley in Small Science
- Vol. 2 (5)
Open AccessUltrafast and Sensitive Screening of Pathogens by Functionalized Janus Microbeads‐Enabled Rotational Diffusometry in Combination with Isothermal Amplification
Polymerase chain reaction (PCR) is widely considered the gold standard in molecular diagnostics because of its high accuracy. However, conventional PCR is very time‐consuming (turnaround time 4–6 h), labor‐intensive, and high‐tech instruments dependent. Therefore, developing an ultrafast and sensitive nucleic amplification‐based detection method is still in high demand. Herein, a rapid screening of Escherichia coli using an advanced and sensitive biosensing method known as rotational diffusometry in combination with loop‐mediated isothermal amplification (LAMP) is reported. Given that the solution viscosity is increased with nucleic acid amplification, the viscosity change can be measured by the functionalized Janus microbeads‐enabled rotational diffusometry. The rotational diffusivity derived from capturing images of microbeads is expressed in terms of blinking signals. Under such conditions, this method can achieve a limit of detection of 42.8 fg μL−1 in 10 min for E. coli with sample volume as low as 2 μL. Additionally, detection of E. coli whole cells extracted from artificially contaminated milk, juice, and water is performed by the developed method and validated with real‐time PCR. Through this biosensing technique, a rapid, reliable, and low sample volume screening tool can be established, improving the shortcomings of the current time‐consuming and labor‐intensive methods.
- 7 October 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (41) , 13945-13951
Rapid and Sensitive Pathogen Detection by DNA Amplification Using Janus Particle-Enabled Rotational Diffusometry
Rapid and sensitive detection of infectious bacteria is in all-time high demand to prevent the further spread of the infection and allow early medical intervention. In this study, we use rotational diffusometry (RD), a natural phenomenon characterized by Janus particles, to detect pathogens like Escherichia coli by performing amplification of specific genes. This biosensing method is used to measure the change in viscosity of the fluid in the presence and absence of DNA in the solution by capturing images of modified microbeads at 10 Hz by a CCD camera followed by cross-correlation algorithm analysis. Using rotational diffusometry, we have achieved E. coli detection with 50 pg/μL DNA with a measurement time of 30 s and a sample volume of 2 μL. This sensitivity was achieved with 30 thermal cycles for three different amplicons, viz., 84, 147, and 246 bp. Meanwhile, in the case of 10 and 20 thermal cycles, the detection sensitivity was achieved with 0.1 and 1 ng/μL DNA concentrations for a 246 bp amplicon. Compared with conventional PCR, this technique appears to improve the detection time, thereby reaching a turnaround time of less than 60 min. Other studies showed a successful identification of DNA amplification up to 10 thermal cycles with different sizes of amplicons. The effect of DNA concentration, amplicon size, and the number of thermal cycles on the detection of E. coli was examined in detail and represented in the form of three maps. These maps show the clear difference and the advantages of RD method in comparison with conventional PCR. This unconventional and rapid biosensing method can be used further for downstream application of nucleic acid amplification-based pathogen detection and early disease control.
- 7 October 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (41) , 13945-13951
Rapid and Sensitive Pathogen Detection by DNA Amplification Using Janus Particle-Enabled Rotational Diffusometry
Rapid and sensitive detection of infectious bacteria is in all-time high demand to prevent the further spread of the infection and allow early medical intervention. In this study, we use rotational diffusometry (RD), a natural phenomenon characterized by Janus particles, to detect pathogens like Escherichia coli by performing amplification of specific genes. This biosensing method is used to measure the change in viscosity of the fluid in the presence and absence of DNA in the solution by capturing images of modified microbeads at 10 Hz by a CCD camera followed by cross-correlation algorithm analysis. Using rotational diffusometry, we have achieved E. coli detection with 50 pg/μL DNA with a measurement time of 30 s and a sample volume of 2 μL. This sensitivity was achieved with 30 thermal cycles for three different amplicons, viz., 84, 147, and 246 bp. Meanwhile, in the case of 10 and 20 thermal cycles, the detection sensitivity was achieved with 0.1 and 1 ng/μL DNA concentrations for a 246 bp amplicon. Compared with conventional PCR, this technique appears to improve the detection time, thereby reaching a turnaround time of less than 60 min. Other studies showed a successful identification of DNA amplification up to 10 thermal cycles with different sizes of amplicons. The effect of DNA concentration, amplicon size, and the number of thermal cycles on the detection of E. coli was examined in detail and represented in the form of three maps. These maps show the clear difference and the advantages of RD method in comparison with conventional PCR. This unconventional and rapid biosensing method can be used further for downstream application of nucleic acid amplification-based pathogen detection and early disease control.
- 1 October 2018
- Published by Elsevier in Inorganica Chimica Acta
- Vol. 482, 597-604
Synthesis and extraction behavior of alkyl and cyclic aminophosphonates towards actinides
- 1 October 2018
- Published by Elsevier in Inorganica Chimica Acta
- Vol. 482, 597-604
Synthesis and extraction behavior of alkyl and cyclic aminophosphonates towards actinides