DBDavid L. Butler

David L. Butler

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


David L. Butler has a total of 83 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Evolution of functional tissue engineering for tendon and ligament repair

    by David L. Butler

    This review paper is motivated by a Back-to-Basics presentation given by the author at the 2022 Orthopaedic Research Society meeting in Tampa, Florida. I was tasked with providing a brief history of research leading up to the introduction of functional tissue engineering (FTE) for tendon and ligament repair. Beginning in the 1970s, this timeline focused on two common orthopedic soft tissue problems, anterior cruciate ligament ruptures in the knee and supraspinatus tendon injuries in the shoulder. Historic changes in the field over the next 5 decades revealed a transformation from a focus more on mechanics (called "bioMECHANICS") on a larger (tissue) scale to a more recent focus on biology (called "mechanoBIOLOGY") on a smaller (cellular and molecular) scale. Early studies by surgeons and engineers revealed the importance of testing conditions for ligaments and tendons (e.g., high strain rates while avoiding subject disuse and immobility) and the need to measure in vivo forces in these tissues. But any true tissue engineering and regeneration in these early decades was limited more to the use of auto-, allo- and xenografts than actual generation of stimulated cell-scaffold constructs in culture. It was only after the discovery of tissue engineering in 1988 and the recognition of frequent rotator cuff injuries in the early 1990s, that biologists joined surgeons and engineers to discover mechanical and biological testing criteria for FTE. This review emphasizes the need for broader and more inclusive collaborations by surgeons, biologists and engineers in the short term with involvement of those in biomaterials, manufacturing, and regulation of new products in the longer term.


  • Open Access

    Effect of ACL graft material on joint forces during a simulated in vivo motion in the porcine knee: Examining force during the initial cycles

    by Daniel V. Boguszewski, Christopher T. Wagner, David L. Butler, Jason T. Shearn

    This study compared three‐dimensional forces in knees containing anterior cruciate ligament (ACL) graft materials versus the native porcine ACL. A six‐degree‐of‐freedom (DOF) robot simulated gait while recording the joint forces and moments. Knees were subjected to 10 cycles of simulated gait in intact, ACL‐deficient, and ACL‐reconstructed knee states to examine time zero biomechanical performance. Reconstruction was performed using bone‐patellar tendon‐bone allograft (BPTB), reconstructive porcine tissue matrix (RTM), and an RTM‐polymer hybrid (Hybrid). Forces and moments were examined about anatomic DOFs throughout the gait cycle and at three key points during gait: heel strike (HS), mid stance (MS), toe off (TO). Compared to native ACL, each graft restored antero‐posterior (A‐P) forces throughout gait. However, all failed to mimic normal joint forces in other DOFs. For example, each reconstructed knee showed greater compressive forces at HS and TO compared to the native ACL knee. Overall, the Hybrid graft restored more of the native ACL forces following reconstruction than did BPTB, while RTM grafts were the least successful. If early onset osteoarthritis is in part caused by altered knee kinematics, then understanding how reconstruction materials restore critical force generation during gait is an essential step in improving a patient's long‐term prognosis. © 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 32:1458–1463, 2014.


  • Evolving Strategies in Mechanobiology to More Effectively Treat Damaged Musculoskeletal Tissues

    by David L. Butler, Nathaniel A. Dyment, Jason T. Shearn, Kirsten R. C. Kinneberg, Andrew P. Breidenbach, Andrea L. Lalley, Steven D. Gilday, Cynthia Gooch, M. B. Rao, Chia-Feng Liu, et al.

    In this paper, we had four primary objectives. (1) We reviewed a brief history of the Lissner award and the individual for whom it is named, H.R. Lissner. We examined the type (musculoskeletal, cardiovascular, and other) and scale (organism to molecular) of research performed by prior Lissner awardees using a hierarchical paradigm adopted at the 2007 Biomechanics Summit of the US National Committee on Biomechanics. (2) We compared the research conducted by the Lissner award winners working in the musculoskeletal (MS) field with the evolution of our MS research and showed similar trends in scale over the past 35 years. (3) We discussed our evolving mechanobiology strategies for treating musculoskeletal injuries by accounting for clinical, biomechanical, and biological considerations. These strategies included studies to determine the function of the anterior cruciate ligament and its graft replacements as well as novel methods to enhance soft tissue healing using tissue engineering, functional tissue engineering, and, more recently, fundamental tissue engineering approaches. (4) We concluded with thoughts about future directions, suggesting grand challenges still facing bioengineers as well as the immense opportunities for young investigators working in musculoskeletal research. Hopefully, these retrospective and prospective analyses will be useful as the ASME Bioengineering Division charts future research directions.


  • Open Access

    The native cell population does not contribute to central‐third graft healing at 6, 12, or 26 weeks in the rabbit patellar tendon

    by Kirsten R.C. Kinneberg, Marc T. Galloway, David L. Butler, Jason T. Shearn

    Investigators do not yet understand the role of intrinsic tendon cells in healing at the tendon‐to‐bone enthesis. Therefore, our first objective was to understand how the native cell population influences tendon autograft incorporation in the central‐third patellar tendon (PT) defect site. To do this, we contrasted the histochemical and biomechanical properties of de‐cellularized patellar tendon autograft (dcPTA) and patellar tendon autograft (PTA) repairs in the skeletally mature New Zealand white rabbit. Recognizing that soft tissues in many animal models require up to 26 weeks to incorporate into bone, our second objective was to investigate how recovery time affects enthesis formation and graft tissue biomechanical properties. Thus, we examined graft structure and mechanics at 6, 12, and 26 weeks post‐surgery. Our results showed that maintaining the native cell population produced no histochemical or biomechanical benefit at 6, 12, or 26 weeks. These findings suggest that PTA healing is mediated more by extrinsic rather than intrinsic cellular mechanisms. Moreover, while repair tissue biomechanical properties generally increased from 6 to 12 weeks after surgery, no further improvements were noted up to 26 weeks. © 2012 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31: 638–644, 2013


  • Effect of Implanting a Soft Tissue Autograft in a Central-Third Patellar Tendon Defect: Biomechanical and Histological Comparisons

    by Kirsten R. C. Kinneberg, Marc T. Galloway, David L. Butler, Jason T. Shearn

    Previous studies by our laboratory have demonstrated that implanting a stiffer tissue engineered construct at surgery is positively correlated with repair tissue stiffness at 12 weeks. The objective of this study was to test this correlation by implanting a construct that matches normal tissue biomechanical properties. To do this, we utilized a soft tissue patellar tendon autograft to repair a central-third patellar tendon defect. Patellar tendon autograft repairs were contrasted against an unfilled defect repaired by natural healing (NH). We hypothesized that after 12 weeks, patellar tendon autograft repairs would have biomechanical properties superior to NH. Bilateral defects were established in the central-third patellar tendon of skeletally mature (one year old), female New Zealand White rabbits (n = 10). In one limb, the excised tissue, the patellar tendon autograft, was sutured into the defect site. In the contralateral limb, the defect was left empty (natural healing). After 12 weeks of recovery, the animals were euthanized and their limbs were dedicated to biomechanical (n = 7) or histological (n = 3) evaluations. Only stiffness was improved by treatment with patellar tendon autograft relative to natural healing (p = 0.009). Additionally, neither the patellar tendon autograft nor natural healing repairs regenerated a normal zonal insertion site between the tendon and bone. Immunohistochemical staining for collagen type II demonstrated that fibrocartilage-like tissue was regenerated at the tendon-bone interface for both repairs. However, the tissue was disorganized. Insufficient tissue integration at the tendon-to-bone junction led to repair tissue failure at the insertion site during testing. It is important to re-establish the tendon-to-bone insertion site because it provides joint stability and enables force transmission from muscle to tendon and subsequent loading of the tendon. Without loading, tendon mechanical properties deteriorate. Future studies by our laboratory will investigate potential strategies to improve patellar tendon autograft integration into bone using this model.


  • Open Access

    Generation and characterization of col10a1-mcherry reporter mice

    by Peter Maye, Yu Fu, David L. Butler, Kumar Chokalingam, Yaling Liu, Jane Floret, Mary Louise Stover, Richard Wenstrup, Xi Jiang, Cindi Gooch, et al.


  • Effect of Surgery to Implant Motion and Force Sensors on Vertical Ground Reaction Forces in the Ovine Model

    by Safa T. Herfat, Jason T. Shearn, Denis L. Bailey, R. Michael Greiwe, Marc T. Galloway, Cindi Gooch, David L. Butler

    Activities of daily living (ADLs) generate complex, multidirectional forces in the anterior cruciate ligament (ACL). While calibration problems preclude direct measurement in patients, ACL forces can conceivably be measured in animals after technical challenges are overcome. For example, motion and force sensors can be implanted in the animal but investigators must determine the extent to which these sensors and surgery affect normal gait. Our objectives in this study were to determine (1) if surgically implanting knee motion sensors and an ACL force sensor significantly alter normal ovine gait and (2) how increasing gait speed and grade on a treadmill affect ovine gait before and after surgery. Ten skeletally mature, female sheep were used to test four hypotheses: (1) surgical implantation of sensors would significantly decrease average and peak vertical ground reaction forces (VGRFs) in the operated limb, (2) surgical implantation would significantly decrease single limb stance duration for the operated limb, (3) increasing treadmill speed would increase VGRFs pre- and post operatively, and (4) increasing treadmill grade would increase the hind limb VGRFs pre- and post operatively. An instrumented treadmill with two force plates was used to record fore and hind limb VGRFs during four combinations of two speeds (1.0 m/s and 1.3 m/s) and two grades (0 deg and 6 deg). Sensor implantation decreased average and peak VGRFs less than 10% and 20%, respectively, across all combinations of speed and grade. Sensor implantation significantly decreased the single limb stance duration in the operated hind limb during inclined walking at 1.3 m/s but had no effect on single limb stance duration in the operated limb during other activities. Increasing treadmill speed increased hind limb peak (but not average) VGRFs before surgery and peak VGRF only in the unoperated hind limb during level walking after surgery. Increasing treadmill grade (at 1 m/s) significantly increased hind limb average and peak VGRFs before surgery but increasing treadmill grade post op did not significantly affect any response measure. Since VGRF values exceeded 80% of presurgery levels, we conclude that animal gait post op is near normal. Thus, we can assume normal gait when conducting experiments following sensor implantation. Ultimately, we seek to measure ACL forces for ADLs to provide design criteria and evaluation benchmarks for traditional and tissue engineered ACL repairs and reconstructions.


  • The use of mesenchymal stem cells in collagen-based scaffolds for tissue-engineered repair of tendons

    by David L Butler, Cynthia Gooch, Kirsten R C Kinneberg, Gregory P Boivin, Marc T Galloway, V Sanjit Nirmalanandhan, Jason T Shearn, Nathaniel A Dyment, Natalia Juncosa-Melvin

    Tendon and ligament injuries are significant contributors to musculoskeletal injuries. Unfortunately, traditional methods of repair are not uniformly successful and can require revision surgery. Our research is focused on identifying appropriate animal injury models and using tissue-engineered constructs (TECs) from bone-marrow-derived mesenchymal stem cells and collagen scaffolds. Critical to this effort has been the development of functional tissue engineering (FTE). We first determine the in vivo mechanical environment acting on the tissue and then precondition the TECs in culture with aspects of these mechanical signals to improve repair outcome significantly. We describe here a detailed protocol for conducting several complete iterations around our FTE 'road map.' The in vitro portion, from bone marrow harvest to TEC collection, takes 54 d. The in vivo portion, from TEC implantation to limb harvest, takes 84 d. One complete loop around the tissue engineering road map, as presented here, takes 138 d to complete.


  • Tensile Stimulation of Murine Stem Cell–Collagen Sponge Constructs Increases Collagen Type I Gene Expression and Linear Stiffness

    by Kumar Chokalingam, Natalia Juncosa-Melvin, Shawn A. Hunter, Cynthia Gooch, Chris Frede, Jane Florert, Gino Bradica, Richard Wenstrup, David L. Butler

    The objectives of this study were to determine how tensile stimulation delivered up to 14 days in culture influenced type I collagen gene expression in stem cells cultured in collagen sponges, and to establish if gene expression, measured using a fluorescence method, correlates with an established method, real-time quantitative reverse transcriptase polymerase chain reaction (qRT-PCR). Using a novel model system, mesenchymal stem cells were harvested from six double transgenic mice in which the type I and type II collagen promoters were linked to green fluorescent protein-topaz and enhanced cyan fluorescent protein, respectively. Tissue-engineered constructs were created by seeding 0.5 × 106 mesenchymal stem cells onto type I collagen sponge scaffolds in a silicone dish. Constructs were then transferred to a custom pneumatic mechanical stimulation system housed in a standard incubator and stimulated for 5 h/day in tension for either 7 or 14 days using a repeated profile (2.4% peak strain for 20 s at 1 Hz followed by a rest period at 0% strain for 100 s). Control specimens were exposed to identical culture conditions but without mechanical stimulation. At three time points (0, 7, and 14 days), constructs were then prepared for evaluation of gene expression using fluorescence analysis and qRT-PCR, and the remaining constructs were failed in tension. Both analytical methods showed that constructs stimulated for 7 and 14 days showed significantly higher collagen type I gene expression than nonstimulated controls at the same time interval. Gene expression measured using qRT-PCR and fluorescence analysis was positively correlated (r = 0.9). Linear stiffness of stimulated constructs was significantly higher at both 7 and 14 days than that of nonstimulated controls at the same time intervals. Linear stiffness of the stimulated constructs at day 14 was significantly different from that of day 7. Future studies will vary the mechanical signal to optimize type I collagen gene expression to improve construct biomechanics and in vivo tendon repair.


  • Three-Dimensional In Vitro Effects of Compression and Time in Culture on Aggregate Modulus and on Gene Expression and Protein Content of Collagen Type II in Murine Chondrocytes

    by Kumar Chokalingam, Shawn Hunter, Cynthia Gooch, Chris Frede, Jane Florer, Richard Wenstrup, David Butler

    The objectives of this study were to determine how culture time and dynamic compression, applied to murine chondrocyte–agarose constructs, influence construct stiffness, expression of col2 and type II collagen. Chondrocytes were harvested from the ribs of six newborn double transgenic mice carrying transgenes that use enhanced cyan fluorescent protein (ECFP) and green fluorescent protein (GFP-T) as reporters for expression from the col2a1 and col1a1 promoters, respectively. Sixty-three constructs (8 mm diameter × 3 mm thick) per animal were created by seeding chondrocytes (10 × 10 6 per mL) in agarose gel (2% w/v). Twenty-eight constructs from each animal were stimulated for 7, 14, 21, or 28 days in a custom bioreactor housed in an electromagnetic system. Twenty-eight constructs exposed to identical culture conditions but without mechanical stimulation served as nonstimulated controls for 7, 14, 21, and 28 days. The remaining seven constructs served as day 0 controls. Fluorescing cells with rounded morphology were present in all constructs at all five time points. Seven, 14, 21, and 28 days of stimulation significantly increased col2 expression according to ECFP fluorescence and messenger RNA expression according to quantitative reverse transcriptase polymerase chain reaction. Col2 gene expression in stimulated and nonstimulated constructs showed initial increases up to day 14 and then showed decreases by day 28. Stimulation significantly increased type II collagen content at 21 and 28 days and aggregate modulus only at 28 days. There was a significant increase in aggregate modulus in stimulated constructs between day 0 and 7 and between day 21 and day 28. This study reveals that compressive mechanical stimulation is a potent stimulator of col2 gene expression that leads to measurable but delayed increases in protein (type II collagen) and then biomechanical stiffness. Future studies will examine the effects of components of the mechanical signal in culture and address the question of whether such in vitro improvements in tissue-engineered constructs enhance repair outcomes after surgery.