Lukas Brunnbauer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lukas Brunnbauer has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Limbeck
TU Wien
10 shared publications Andreas Limbeck
TU Wien, Institute of Chemical Technologies and Analytics, Getreidemarkt 9/164-I2AC, Vienna, 1060, Austria
3 shared publications- David Ken Gibbs
TU Wien, Institute of Chemical Technologies and Analytics, Getreidemarkt 9/164, 1060 Vienna, Austria
3 shared publications - Jakob Willner
Institute of Chemical Technologies and Analytics (E164), TU Wien, Getreidemarkt 9, 1060 Vienna, Austria
3 shared publications - Jozef Kaiser
Central European Institute of Technology, Brno University of Technology, 61200 Brno, Czech Republic
3 shared publications Michael Nelhiebel
KAI Kompetenzzentrum Automobil-und Industrieelektronik GmbH, Technologiepark Villach – Europastraße 8, 8524 Villach, Austria
3 shared publications
Latest Publications
- Open Access
- 15 April 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (16) , 11760-11768
A Method for the Detection of Tire Wear Microplastics in Zebrafish Guts by Laterally Resolved LA-ICP-MS-Based Elemental Fingerprinting and Chemometrics
Tire wear particles (TWPs) are generated by mechanical abrasion of tires on road surfaces and represent a significant source of microplastic pollution, contributing an estimated 30-50% of total microplastic emissions in Europe. Due to their persistence and limited biodegradability, TWPs accumulate in terrestrial, aquatic, and atmospheric environments. However, their detection and quantification remain challenging: carbon black hampers FTIR analysis, while pyrolysis-GC-MS yields only bulk mass data without information about particle abundance or size distribution. We present a novel approach to address this gap using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) combined with elemental fingerprinting and machine learning. We apply this method to zebrafish gut tissue to differentiate TWPs from biological tissue, paraffin-embedded material, and other naturally occurring particles. A random forest model trained on multielement signatures enables pixelwise classification of imaging data recorded with 7-μm lateral resolution despite the complexity of both TWP and biological matrices. Our results demonstrate the potential of LA-ICP-MS elemental imaging as a sensitive tool for TWP detection in biological tissue, providing new opportunities for monitoring and ecotoxicological studies.
- 15 April 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (16) , 11760-11768
Open AccessA Method for the Detection of Tire Wear Microplastics in Zebrafish Guts by Laterally Resolved LA-ICP-MS-Based Elemental Fingerprinting and Chemometrics
Tire wear particles (TWPs) are generated by mechanical abrasion of tires on road surfaces and represent a significant source of microplastic pollution, contributing an estimated 30-50% of total microplastic emissions in Europe. Due to their persistence and limited biodegradability, TWPs accumulate in terrestrial, aquatic, and atmospheric environments. However, their detection and quantification remain challenging: carbon black hampers FTIR analysis, while pyrolysis-GC-MS yields only bulk mass data without information about particle abundance or size distribution. We present a novel approach to address this gap using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) combined with elemental fingerprinting and machine learning. We apply this method to zebrafish gut tissue to differentiate TWPs from biological tissue, paraffin-embedded material, and other naturally occurring particles. A random forest model trained on multielement signatures enables pixelwise classification of imaging data recorded with 7-μm lateral resolution despite the complexity of both TWP and biological matrices. Our results demonstrate the potential of LA-ICP-MS elemental imaging as a sensitive tool for TWP detection in biological tissue, providing new opportunities for monitoring and ecotoxicological studies.
- Open Access
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
Cryogenic LA-sp-ICP-MS for direct analysis of aqueous microplastics suspensions
Cryogenic LA-sp-ICP-MS extends microplastic detection below 1 µm while remaining robust against dissolved organic carbon matrices.
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
Open AccessCryogenic LA-sp-ICP-MS for direct analysis of aqueous microplastics suspensions
Cryogenic LA-sp-ICP-MS extends microplastic detection below 1 µm while remaining robust against dissolved organic carbon matrices.
- Open Access
- 15 September 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (37) , 20108-20116
Signal Perception in Two-Dimensional Mapping Techniques: Just Noticeable Difference as a Visual Limit of Detection
The limit of detection (LOD) is a ubiquitous figure of merit for characterizing the performance of instrumental methods in analytical chemistry, with the well-known formula "three times the standard deviation of the blank" serving as a common heuristic for assessing signal detection. However, in two-dimensional (2D) data settings from elemental imaging and mapping techniques, signals below the LOD often remain visually discernible. Inspired by the theory of psychophysics, we propose the Just-Noticeable Difference (JND) as a novel figure of merit for chemical data analysis in 2D contexts. The JND refers to the smallest perceptible difference between two stimuli by the human senses. By utilizing the JND as a guiding principle in targeting low-contrast signals, we offer an alternative approach to understanding detection limits in 2D data sets, with enhanced sensitivity for a large variety of sizes of spatially resolved signal and noise levels. The potential of this approach, which is presented in two different mapping techniques, LA-ICP-MS and LIBS, is compared to the standard LOD metric, which hints at the possibility for more accurate assessments of elemental concentrations and better utilization of contrast variations and spatial information inherent in mapping techniques.
- 15 September 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (37) , 20108-20116
Open AccessSignal Perception in Two-Dimensional Mapping Techniques: Just Noticeable Difference as a Visual Limit of Detection
The limit of detection (LOD) is a ubiquitous figure of merit for characterizing the performance of instrumental methods in analytical chemistry, with the well-known formula "three times the standard deviation of the blank" serving as a common heuristic for assessing signal detection. However, in two-dimensional (2D) data settings from elemental imaging and mapping techniques, signals below the LOD often remain visually discernible. Inspired by the theory of psychophysics, we propose the Just-Noticeable Difference (JND) as a novel figure of merit for chemical data analysis in 2D contexts. The JND refers to the smallest perceptible difference between two stimuli by the human senses. By utilizing the JND as a guiding principle in targeting low-contrast signals, we offer an alternative approach to understanding detection limits in 2D data sets, with enhanced sensitivity for a large variety of sizes of spatially resolved signal and noise levels. The potential of this approach, which is presented in two different mapping techniques, LA-ICP-MS and LIBS, is compared to the standard LOD metric, which hints at the possibility for more accurate assessments of elemental concentrations and better utilization of contrast variations and spatial information inherent in mapping techniques.
- Open Access
- 21 August 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (11) , 3044-3062
Laser ablation-based techniques for microplastic analysis: recent advances and applications
Microplastics have emerged as significant environmental contaminants due to the increasing production of polymer-based products and their limited disposal options.
- 21 August 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (11) , 3044-3062
Open AccessLaser ablation-based techniques for microplastic analysis: recent advances and applications
Microplastics have emerged as significant environmental contaminants due to the increasing production of polymer-based products and their limited disposal options.
- Open Access
- 18 July 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1372, 344443
On the two-phase sample transport of carbon in LA-ICP-MS and its practical implications for trace metal analysis in polymer matrices: classification and sensitivity
- 18 July 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1372, 344443
Open AccessOn the two-phase sample transport of carbon in LA-ICP-MS and its practical implications for trace metal analysis in polymer matrices: classification and sensitivity
- Open Access
- 2 July 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (27) , 14521-14530
Single-Pulse Response LA-ICP-MS Imaging with Quadrupole Instrumentation: Theoretical Considerations and Practical Assessment
Recent instrumental developments in LA-ICP-MS, such as rapid response cells that significantly reduce the washout and the introduction of high-repetition rate lasers, have greatly impacted the field. To fully take advantage of these developments, improvements on the ICP-MS side were necessary. This was achieved by establishing ICP-TOF-MS instruments enabling simultaneous multielement detection suitable for recording the short transient signals generated by modern rapid response cells. These developments enabled a new operational mode for imaging called the single-pulse response (SPR). Nevertheless, quadrupole-based ICP-MS (ICP-Q-MS) instruments are still the most prevalent instrument type nowadays. Even though it provides many benefits, SPR-based imaging has not yet been applied to ICP-Q-MS due to the sequential m/z detection. However, recent developments enabling shorter dwell times and settling times of ICP-Q-MS systems make a SPR-based imaging approach feasible. In this work, we investigate the potential and limitations of SPR-based imaging using ICP-Q-MS. Therefore, we investigate the relationship between the cycle time and the signal stability by evaluating 107Ag/109Ag while ablating NIST SRM 612. With the results derived, theoretical considerations about the relationship between the peak width, laser repetition rate, and dwell times can be confirmed. In the next step, the effects of different dwell times on image quality and image artifacts are evaluated by imaging a test structure. Finally, the applicability of the SPR-based LA-ICP-Q-MS imaging approach is demonstrated for life science applications by showing SPR multielement measurements of Haematococcus pluvialis cell samples, detecting 4 elements with a pixel acquisition rate of 100 Hz.
- 2 July 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (27) , 14521-14530
Open AccessSingle-Pulse Response LA-ICP-MS Imaging with Quadrupole Instrumentation: Theoretical Considerations and Practical Assessment
Recent instrumental developments in LA-ICP-MS, such as rapid response cells that significantly reduce the washout and the introduction of high-repetition rate lasers, have greatly impacted the field. To fully take advantage of these developments, improvements on the ICP-MS side were necessary. This was achieved by establishing ICP-TOF-MS instruments enabling simultaneous multielement detection suitable for recording the short transient signals generated by modern rapid response cells. These developments enabled a new operational mode for imaging called the single-pulse response (SPR). Nevertheless, quadrupole-based ICP-MS (ICP-Q-MS) instruments are still the most prevalent instrument type nowadays. Even though it provides many benefits, SPR-based imaging has not yet been applied to ICP-Q-MS due to the sequential m/z detection. However, recent developments enabling shorter dwell times and settling times of ICP-Q-MS systems make a SPR-based imaging approach feasible. In this work, we investigate the potential and limitations of SPR-based imaging using ICP-Q-MS. Therefore, we investigate the relationship between the cycle time and the signal stability by evaluating 107Ag/109Ag while ablating NIST SRM 612. With the results derived, theoretical considerations about the relationship between the peak width, laser repetition rate, and dwell times can be confirmed. In the next step, the effects of different dwell times on image quality and image artifacts are evaluated by imaging a test structure. Finally, the applicability of the SPR-based LA-ICP-Q-MS imaging approach is demonstrated for life science applications by showing SPR multielement measurements of Haematococcus pluvialis cell samples, detecting 4 elements with a pixel acquisition rate of 100 Hz.
- Open Access
- 30 June 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (8) , 2179-2186
Investigating the sensitivity difference of gaseous and particulate carbon in two-phase sample transport in LA-ICP-MS
Quantitative assessment of the sensitivity difference of gaseous and particulate carbon in LA-ICP-MS.
- 30 June 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (8) , 2179-2186
Open AccessInvestigating the sensitivity difference of gaseous and particulate carbon in two-phase sample transport in LA-ICP-MS
Quantitative assessment of the sensitivity difference of gaseous and particulate carbon in LA-ICP-MS.
- Open Access
- 27 January 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (3) , 753-761
Novel calibration approach for particle size analysis of microplastics by laser ablation single particle-ICP-MS
This work demonstrates and investigates a calibration approach for sizing microplastic particles using single particle ICP-MS with laser ablation sampling circumventing the need for particulate standard material.
- 27 January 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (3) , 753-761
Open AccessNovel calibration approach for particle size analysis of microplastics by laser ablation single particle-ICP-MS
This work demonstrates and investigates a calibration approach for sizing microplastic particles using single particle ICP-MS with laser ablation sampling circumventing the need for particulate standard material.
- Open Access
Capabilities of simultaneous 193 nm - LIBS/LA-ICP-MS imaging for microplastics characterization
- Open Access
- 4 September 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 38 (10) , 2028-2037
Development of a simultaneous LA-ICP-MS & LIBS method for the investigation of polymer degradation
A combined LA-ICP-MS & LIBS method was developed for analysis of polymer thin films, providing spatially resolved information on polymer degradation caused by UV radiation, H2S weathering, or exposure to both.
- 4 September 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 38 (10) , 2028-2037
Open AccessDevelopment of a simultaneous LA-ICP-MS & LIBS method for the investigation of polymer degradation
A combined LA-ICP-MS & LIBS method was developed for analysis of polymer thin films, providing spatially resolved information on polymer degradation caused by UV radiation, H2S weathering, or exposure to both.