Rabeeah S. Altarhouni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rabeeah S. Altarhouni has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Mohamed Burid Milad
Libyan Biotechnology Research Center, Tripoli P.O. Box 30313, Libya
2 shared publications - Adam Elzagheid
Genetic Engineering Department, Biotechnology Research Center, Tripoli, Libya
1 shared publication - Ainur Toigozhinova
School of Technologies, Mukhametzhan Tynyshbayev ALT University, Shevchenko St. 97, 050012 Almaty, Kazakhstan
1 shared publication - Asma Alboeshi
Libyan Biotechnology Research Center, Tripoli P.O. Box 30313, Libya
1 shared publication - Ellafi. A. Elbahri
Libyan Biotechnology Research Center, Tripoli P.O. Box 30313, Libya
1 shared publication - Esam Alsadiq Alshareef
Libyan Biotechnology Research Center, Tripoli P.O. Box 30313, Libya
1 shared publication
Latest Publications
- Open Access
- 12 June 2026
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 16 (6) , 314
Knee Osteoarthritis Severity Grading Using Contrastive Learning Image Pre-Training
Background/Objectives: Accurate evaluation of knee osteoarthritis (KOA) severity is critical for optimal patient care, yet manual radiographic grading remains subject to observer variability. This study aims to evaluate the performance of a fine-tuned contrastive language–image pre-training (CLIP) framework designed to assist clinicians in grading KOA severity in plain radiographs using the Kellgren–Lawrence (KL) classification system (Grades 0–4). Methods: The model operates by projecting visual features from radiographs and standard textual clinical descriptions into a shared embedding space. Training was conducted using 8260 posterior–anterior (PA) fixed-flexion X-ray images from the Osteoarthritis Initiative (OAI) dataset. For robust external evaluation across distinct data distributions, the model was tested on an independent dataset consisting of 1650 plain radiographs. Results: When evaluated on the external validation dataset, the fine-tuned CLIP model achieved an accuracy of 76.94% and an F1-score of 76.66%. Comparative analysis demonstrates that these aligned vision-language representations provide competitive, stable diagnostic capabilities even when applied to an entirely independent data distribution. Conclusions: Fine-tuned CLIP architectures offer a viable and valuable foundation for semantically transparent, computer-aided evaluation of KOA.
- 12 June 2026
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 16 (6) , 314
Open AccessKnee Osteoarthritis Severity Grading Using Contrastive Learning Image Pre-Training
Background/Objectives: Accurate evaluation of knee osteoarthritis (KOA) severity is critical for optimal patient care, yet manual radiographic grading remains subject to observer variability. This study aims to evaluate the performance of a fine-tuned contrastive language–image pre-training (CLIP) framework designed to assist clinicians in grading KOA severity in plain radiographs using the Kellgren–Lawrence (KL) classification system (Grades 0–4). Methods: The model operates by projecting visual features from radiographs and standard textual clinical descriptions into a shared embedding space. Training was conducted using 8260 posterior–anterior (PA) fixed-flexion X-ray images from the Osteoarthritis Initiative (OAI) dataset. For robust external evaluation across distinct data distributions, the model was tested on an independent dataset consisting of 1650 plain radiographs. Results: When evaluated on the external validation dataset, the fine-tuned CLIP model achieved an accuracy of 76.94% and an F1-score of 76.66%. Comparative analysis demonstrates that these aligned vision-language representations provide competitive, stable diagnostic capabilities even when applied to an entirely independent data distribution. Conclusions: Fine-tuned CLIP architectures offer a viable and valuable foundation for semantically transparent, computer-aided evaluation of KOA.
- Open Access
Anti-SARS-CoV-2 IgG Antibodies Post-COVID-19 or Post-Vaccination in Libyan Population: Comparison of Four Vaccines
Measurement of strength and durability of SARS-COV-2 antibody response is important to understand the waning dynamics of immune response to both vaccines and infection. The study aimed to evaluate the level of IgG antibodies against SARS-CoV-2 and their persistence in recovered, naïve, and vaccinated individuals. We investigated anti-spike RBD IgG antibody responses in 10,000 individuals, both following infection with SARS-CoV-2 and immunization with SARS-COV-2 AstraZeneca, Sputnik V, Sinopharm, and Sinovac. The mean levels of anti-spike IgG antibodies were higher in vaccinated participants with prior COVID-19 than in individuals without prior COVID-19. Overall, antibody titers in recovered vaccinee and naïve vaccinee persisted beyond 20 weeks. Vaccination with adenoviral–vector vaccines (AstraZeneca and Sputnik V) generates higher antibody titers than with killed virus vaccine (Sinopharm and Sinovac). Approximately two-thirds of asymptomatic unvaccinated individuals had developed virus-specific antibodies. A single dose of vaccine is likely to provide greater protection against SARS-CoV-2 infection in individuals with apparent prior SARS-CoV-2 infection, than in SARS-CoV-2-naive individuals. In addition, the high number of seropositivity among asymptomatic unvaccinated individuals showed that the number of infections are probably highly underestimated. Those vaccinated with inactivated vaccine may require more frequent boosters than those vaccinated with adenoviral vaccine. These findings are important for formulating public health vaccination strategies during COVID-19 pandemic.
Open AccessAnti-SARS-CoV-2 IgG Antibodies Post-COVID-19 or Post-Vaccination in Libyan Population: Comparison of Four Vaccines
Measurement of strength and durability of SARS-COV-2 antibody response is important to understand the waning dynamics of immune response to both vaccines and infection. The study aimed to evaluate the level of IgG antibodies against SARS-CoV-2 and their persistence in recovered, naïve, and vaccinated individuals. We investigated anti-spike RBD IgG antibody responses in 10,000 individuals, both following infection with SARS-CoV-2 and immunization with SARS-COV-2 AstraZeneca, Sputnik V, Sinopharm, and Sinovac. The mean levels of anti-spike IgG antibodies were higher in vaccinated participants with prior COVID-19 than in individuals without prior COVID-19. Overall, antibody titers in recovered vaccinee and naïve vaccinee persisted beyond 20 weeks. Vaccination with adenoviral–vector vaccines (AstraZeneca and Sputnik V) generates higher antibody titers than with killed virus vaccine (Sinopharm and Sinovac). Approximately two-thirds of asymptomatic unvaccinated individuals had developed virus-specific antibodies. A single dose of vaccine is likely to provide greater protection against SARS-CoV-2 infection in individuals with apparent prior SARS-CoV-2 infection, than in SARS-CoV-2-naive individuals. In addition, the high number of seropositivity among asymptomatic unvaccinated individuals showed that the number of infections are probably highly underestimated. Those vaccinated with inactivated vaccine may require more frequent boosters than those vaccinated with adenoviral vaccine. These findings are important for formulating public health vaccination strategies during COVID-19 pandemic.