Feifan Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Feifan Wang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Bo Gao
School of Energy and Power Engineering, Jiangsu University, Zhenjiang 212013, China
2 shared publications - Dan Ni
School of Energy and Power Engineering, Jiangsu University, Zhenjiang 212013, China
2 shared publications - Jinbo Chen
School of Energy and Power Engineering, Jiangsu University, Zhenjiang 212013, China
1 shared publication - Shiyuan Huang
School of Energy and Power Engineering, Jiangsu University, Zhenjiang 212013, China
1 shared publication - Yang Zhang
Shanghai Marine Equipment Research Institute (SMERI), Shanghai 200031, China
1 shared publication - Yang Zhang
Shanghai Marine Equipment Research Institute (SMERI), Shanghai 200031, China
1 shared publication
Latest Publications
- Open Access
Investigation into Dynamic Pressure Pulsation Characteristics in a Centrifugal Pump with Staggered Impeller
For the centrifugal pump, the rotor–stator interaction (RSI) induces high-energy pressure pulsation, which directly affects the stability of systems and equipment. Therefore, this work proposes a new staggered impeller structure to suppress high-energy pressure pulsation in centrifugal pumps. The original impeller blade is divided into two layers and is staggered at 10°, 20° and 30° to form a staggered impeller. The dynamic pressure pulsation characteristics of both the original impeller and the staggered impeller are predicted using large eddy simulation (LES). The results indicate that the uniform staggered arrangement of blades can significantly reduce the pressure pulsation energy in the pump by 54.69% under the design conditions, while also achieving the best performance. Even under off-design conditions, the pressure pulsation energy can still be effectively suppressed by the staggered blades. The study of the time–frequency domain of the monitoring points near the tongue found that the phase difference in the pressure fluctuation caused by the RSI between the staggered impeller and the tongue prevents the superposition of pressure pulsation energy and efficiently suppresses it in the pump. The results can provide a reference for optimizing low-vibration-noise pump impellers in engineering applications.
Open AccessInvestigation into Dynamic Pressure Pulsation Characteristics in a Centrifugal Pump with Staggered Impeller
For the centrifugal pump, the rotor–stator interaction (RSI) induces high-energy pressure pulsation, which directly affects the stability of systems and equipment. Therefore, this work proposes a new staggered impeller structure to suppress high-energy pressure pulsation in centrifugal pumps. The original impeller blade is divided into two layers and is staggered at 10°, 20° and 30° to form a staggered impeller. The dynamic pressure pulsation characteristics of both the original impeller and the staggered impeller are predicted using large eddy simulation (LES). The results indicate that the uniform staggered arrangement of blades can significantly reduce the pressure pulsation energy in the pump by 54.69% under the design conditions, while also achieving the best performance. Even under off-design conditions, the pressure pulsation energy can still be effectively suppressed by the staggered blades. The study of the time–frequency domain of the monitoring points near the tongue found that the phase difference in the pressure fluctuation caused by the RSI between the staggered impeller and the tongue prevents the superposition of pressure pulsation energy and efficiently suppresses it in the pump. The results can provide a reference for optimizing low-vibration-noise pump impellers in engineering applications.
- Open Access
Experimental Investigation on the Effect of the Staggered Impeller on the Unsteady Pressure Pulsations Characteristic in a Pump
High−energy pressure pulsation induced by rotor−stator interaction (RSI) is the primary source of flow−induced vibration noise in the pump, affecting the pump’s stability and system operation. In order to find an effective method to suppress the pressure pulsation in the pump caused by RSI, a new staggered impeller is proposed in this paper, which can significantly suppress the pressure pulsation energy. The unsteady pressure pulsation characteristic of the original impeller and the staggered impeller scheme are measured and analyzed under different working flow conditions. The results show that although the hydraulic performance of the model pump decreases to a certain extent when the staggered impeller is used, the pressure pulsation energy in the pump decreases significantly. Under 0.8QN–1.2QN working flow conditions, the energy suppression effect of the blade passing frequency (fbpf) amplitude is higher than 80% with the staggered impeller scheme. The Root Mean Square (RMS) values for distribution of pressure pulsation in different frequency bands varies greatly, and the pressure pulsation energy near the tongue is prominent. On a broader frequency band (0–6 fbpf), the pressure pulsation energy of the staggered impeller scheme is smaller than that of the original impeller scheme. With the expansion of the frequency band, the pressure pulsation energy decreased steadily, with a minimum decrease of 37.33%.
Open AccessExperimental Investigation on the Effect of the Staggered Impeller on the Unsteady Pressure Pulsations Characteristic in a Pump
High−energy pressure pulsation induced by rotor−stator interaction (RSI) is the primary source of flow−induced vibration noise in the pump, affecting the pump’s stability and system operation. In order to find an effective method to suppress the pressure pulsation in the pump caused by RSI, a new staggered impeller is proposed in this paper, which can significantly suppress the pressure pulsation energy. The unsteady pressure pulsation characteristic of the original impeller and the staggered impeller scheme are measured and analyzed under different working flow conditions. The results show that although the hydraulic performance of the model pump decreases to a certain extent when the staggered impeller is used, the pressure pulsation energy in the pump decreases significantly. Under 0.8QN–1.2QN working flow conditions, the energy suppression effect of the blade passing frequency (fbpf) amplitude is higher than 80% with the staggered impeller scheme. The Root Mean Square (RMS) values for distribution of pressure pulsation in different frequency bands varies greatly, and the pressure pulsation energy near the tongue is prominent. On a broader frequency band (0–6 fbpf), the pressure pulsation energy of the staggered impeller scheme is smaller than that of the original impeller scheme. With the expansion of the frequency band, the pressure pulsation energy decreased steadily, with a minimum decrease of 37.33%.