Akira Ota
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Akira Ota has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Yoshihiro Mogi
Design Division Taisei Corporation Tokyo Japan
3 shared publications - Naohiro Nakamura
Research and Development Institute, Takenaka Corporation, 1-5-1, Ohtsuka, Inzai, Chiba 270-1395, Japan
2 shared publications Akemi Nishida
1 shared publicationByunghyun Choi
1 shared publicationHideaki Sonobe
1 shared publicationKunihiko Nabeshima
Graduate School of Engineering Kobe University Kobe‐shi Japan
1 shared publication
Latest Publications
- 18 August 2025
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 444
Foundation uplift nonlinearity in 3D finite element seismic response analysis: Sensitivity and validation study
- 18 August 2025
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 444
Foundation uplift nonlinearity in 3D finite element seismic response analysis: Sensitivity and validation study
- Open Access
- 1 January 2024
- Published by Wiley in JAPAN ARCHITECTURAL REVIEW
- Vol. 7 (1)
Fundamental study of damping models with enhanced frequency independence in nonlinear seismic response analysis
Causal hysteretic damping, extended Rayleigh damping, and uniform damping models exhibit frequency‐independent damping ratios over a wide frequency range. However, several points remain unclear regarding their applicability to inelastic problems. Therefore, in this study, to compare the vibration characteristics of these damping models, analyses are performed by inputting white noise into simple models with various natural frequencies. Results confirm that these damping models are frequency‐independent even under inelastic conditions. Further, the causal hysteretic and extended Rayleigh damping models have the same computation order as that of conventional Rayleigh damping and can therefore be calculated in approximately the same time.
- 1 January 2024
- Published by Wiley in JAPAN ARCHITECTURAL REVIEW
- Vol. 7 (1)
Open AccessFundamental study of damping models with enhanced frequency independence in nonlinear seismic response analysis
Causal hysteretic damping, extended Rayleigh damping, and uniform damping models exhibit frequency‐independent damping ratios over a wide frequency range. However, several points remain unclear regarding their applicability to inelastic problems. Therefore, in this study, to compare the vibration characteristics of these damping models, analyses are performed by inputting white noise into simple models with various natural frequencies. Results confirm that these damping models are frequency‐independent even under inelastic conditions. Further, the causal hysteretic and extended Rayleigh damping models have the same computation order as that of conventional Rayleigh damping and can therefore be calculated in approximately the same time.
- Open Access
- 20 June 2023
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 52 (12) , 3746-3764
Performance of inherent damping models in inelastic seismic analysis for tall building subject to simultaneous horizontal and vertical seismic motion
In recent seismic analyses, it is considered that the structural damping ratio should be treated as independent of frequency, for safety side estimation. Therefore, frequency‐insensitive damping is required for realistic seismic simulations. This paper investigates the performance of various sparse matrix damping models (extended Raleigh, capped viscous and uniform damping) in the inelastic seismic analysis of a 35‐story moment‐frame steel building. These sparse matrix damping models were compared with Rayleigh, tangent Rayleigh, and Wilson‐Penzien (modal) damping models to provide insight into damping models suitable for large‐scale inelastic response history analysis (RHA). First, the necessity of frequency‐insensitive damping in large‐scale analysis is illustrated via numerical simulations. Then, the vibration characteristics with simultaneous inputs of horizontal and vertical ground motion are analyzed using the abovementioned damping schemes, and their results are compared. The comparisons are analyzed by focusing on horizontal displacement/acceleration, story drift angle, beam‐end ductility factor, the amplitude due to beam vibration, and the associated vertical acceleration. Finally, the computation speeds are compared. As a result, it is shown that although these sparse matrix damping models are practically useful, they are not yet sufficient and present challenges.
- 20 June 2023
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 52 (12) , 3746-3764
Open AccessPerformance of inherent damping models in inelastic seismic analysis for tall building subject to simultaneous horizontal and vertical seismic motion
In recent seismic analyses, it is considered that the structural damping ratio should be treated as independent of frequency, for safety side estimation. Therefore, frequency‐insensitive damping is required for realistic seismic simulations. This paper investigates the performance of various sparse matrix damping models (extended Raleigh, capped viscous and uniform damping) in the inelastic seismic analysis of a 35‐story moment‐frame steel building. These sparse matrix damping models were compared with Rayleigh, tangent Rayleigh, and Wilson‐Penzien (modal) damping models to provide insight into damping models suitable for large‐scale inelastic response history analysis (RHA). First, the necessity of frequency‐insensitive damping in large‐scale analysis is illustrated via numerical simulations. Then, the vibration characteristics with simultaneous inputs of horizontal and vertical ground motion are analyzed using the abovementioned damping schemes, and their results are compared. The comparisons are analyzed by focusing on horizontal displacement/acceleration, story drift angle, beam‐end ductility factor, the amplitude due to beam vibration, and the associated vertical acceleration. Finally, the computation speeds are compared. As a result, it is shown that although these sparse matrix damping models are practically useful, they are not yet sufficient and present challenges.
- Open Access
- 17 November 2022
- Published by Wiley in JAPAN ARCHITECTURAL REVIEW
- Vol. 6 (1)
Application of extended Rayleigh damping model to 3D frame analysis
Rayleigh damping is commonly used in response history analysis (RHA) to provide an energy dissipation source, but the adaptation may be difficult if frequency independence damping is desired over a wide frequency range. And, while modal damping produces constant frequency‐independent damping, the damping matrix becomes dense, increasing the calculation weight is large. This study examines the advantage of using extended Rayleigh damping in the RHA. First, the multi spring‐mass system is used to assess the basic damping performance of the extended Rayleigh damping in the assumed frequency range. A 12‐story 3D elastic moment frame model is then used to compare the damping performance. As a result, extended Rayleigh damping is demonstrated to be frequency independent over a wider frequency range than Rayleigh damping and less computationally demanding than modal damping.
- 17 November 2022
- Published by Wiley in JAPAN ARCHITECTURAL REVIEW
- Vol. 6 (1)
Open AccessApplication of extended Rayleigh damping model to 3D frame analysis
Rayleigh damping is commonly used in response history analysis (RHA) to provide an energy dissipation source, but the adaptation may be difficult if frequency independence damping is desired over a wide frequency range. And, while modal damping produces constant frequency‐independent damping, the damping matrix becomes dense, increasing the calculation weight is large. This study examines the advantage of using extended Rayleigh damping in the RHA. First, the multi spring‐mass system is used to assess the basic damping performance of the extended Rayleigh damping in the assumed frequency range. A 12‐story 3D elastic moment frame model is then used to compare the damping performance. As a result, extended Rayleigh damping is demonstrated to be frequency independent over a wider frequency range than Rayleigh damping and less computationally demanding than modal damping.