Gengming Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gengming Liu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Qingxin Shi
Department of Electrical and Electronics Engineering, North China Electric Power University, Beijing, China
3 shared publications - Rui Cheng
Department of Electrical and Electronics Engineering, North China Electric Power University, Beijing, China
3 shared publications - Wenxia Liu
Department of Electrical and Electronics Engineering, North China Electric Power University, Beijing, China
3 shared publications Wenxia Liu
School of Electrical and Electronic Engineering North China Electric Power University Beijing China
2 shared publicationsYuze Yang
North China Electric Power University
2 shared publicationsBingrui Yan
Department of Electrical and Electronics Engineering, North China Electric Power University, Beijing, China
1 shared publication
Latest Publications
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (5) , 4266-4279
Data-Driven Distribution Network Modeling Using Shallow Physics-Informed Neural Network
Accurate topology and line parameters are fundamental for the planning, operation, and control of distribution networks. Motivated by the physics and characteristics of the distribution network power flow, a shallow physics-informed neural network (SPINN), based on the input convex neural network (ICNN), is elegantly designed to perform data-driven distribution network modeling, enabling the joint estimation of distribution network topology and line parameters. The proposed data-driven distribution network modeling establishes an analytical expression and mapping between the SPINN parameters and distribution network parameters, allowing the distribution network parameters, i.e., topologies and line parameters, to be directly calculated and inferred from the neural network parameters. The performance of the distribution network modeling method is further proved theoretically and verified on the IEEE 33, 69, and 123-bus systems. The results show that our proposed method can accurately estimate the topology and line parameters.
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (5) , 4266-4279
Data-Driven Distribution Network Modeling Using Shallow Physics-Informed Neural Network
Accurate topology and line parameters are fundamental for the planning, operation, and control of distribution networks. Motivated by the physics and characteristics of the distribution network power flow, a shallow physics-informed neural network (SPINN), based on the input convex neural network (ICNN), is elegantly designed to perform data-driven distribution network modeling, enabling the joint estimation of distribution network topology and line parameters. The proposed data-driven distribution network modeling establishes an analytical expression and mapping between the SPINN parameters and distribution network parameters, allowing the distribution network parameters, i.e., topologies and line parameters, to be directly calculated and inferred from the neural network parameters. The performance of the distribution network modeling method is further proved theoretically and verified on the IEEE 33, 69, and 123-bus systems. The results show that our proposed method can accurately estimate the topology and line parameters.
- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Intelligent Transportation Systems
- Vol. 26 (11) , 20274-20286
Resilience Assessment for Urban Power-Metro Interdependent Networks
The power supply from urban power network (UPN) ensures the proper operation of the urban metro network (MN). However, due to the close mutual connections, the negative impact of a power outage can propagate to the MN through a traction power network (TPN). Therefore, it is pressing to assess the resilience of such coupled networks. This paper initially proposes a multi-layer power-metro interdependent network (PMIN) model by integrating physical characteristics of UPN, TPN and MN into their topology networks. In the PMIN, the interdependence of UPN, TPN and MN is established in a hierarchical manner, where the community-based TPN model is practically elaborated to bridge fault propagation from the disabled UPN the to MN. Next, the traditional MN is equivalently converted into a mission-oriented network to simulate passenger rerouting processes, enabling the exploration of rerouting-incurred cascading failure with three proposed failed load redistribution disciplines. Finally, the resilience curves and assessment metrics are proposed to evaluate the resilience of the PMIN, with consideration of coupling effects among the UPN, TPN, and MN. The proposed method is applied to a quasi-authentic PMIN to reveal the fault propagation mechanisms and vulnerability characteristics of critical components within the PMIN, ultimately contributing to resilience enhancement.
- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Intelligent Transportation Systems
- Vol. 26 (11) , 20274-20286
Resilience Assessment for Urban Power-Metro Interdependent Networks
The power supply from urban power network (UPN) ensures the proper operation of the urban metro network (MN). However, due to the close mutual connections, the negative impact of a power outage can propagate to the MN through a traction power network (TPN). Therefore, it is pressing to assess the resilience of such coupled networks. This paper initially proposes a multi-layer power-metro interdependent network (PMIN) model by integrating physical characteristics of UPN, TPN and MN into their topology networks. In the PMIN, the interdependence of UPN, TPN and MN is established in a hierarchical manner, where the community-based TPN model is practically elaborated to bridge fault propagation from the disabled UPN the to MN. Next, the traditional MN is equivalently converted into a mission-oriented network to simulate passenger rerouting processes, enabling the exploration of rerouting-incurred cascading failure with three proposed failed load redistribution disciplines. Finally, the resilience curves and assessment metrics are proposed to evaluate the resilience of the PMIN, with consideration of coupling effects among the UPN, TPN, and MN. The proposed method is applied to a quasi-authentic PMIN to reveal the fault propagation mechanisms and vulnerability characteristics of critical components within the PMIN, ultimately contributing to resilience enhancement.
- 31 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (5) , 3708-3721
Vulnerable Node Identification for Urban Power Networks Under Deliberate Attacks With Incomplete Grid Information
From the perspective of attacker, the target urban power system (UPN) is not fully observable, especially for urban cables placed underground, posing great challenges for making attack decisions. To this end, this paper proposes an attack strategy to identify vulnerable nodes for UPN with incomplete grid information. First, a topology completion model for UPN is developed by utilizing the observable sign information of urban cables and knowledge-guided completion rules. Next, a bi-level mixed-integer program is established to maximize the attack risk, i.e., the node attack probability multiplied by the load loss, where the attack and defense strategies are considered and simulated in the outer and inner level, respectively. Furthermore, the influence of the completion accuracy is taken into account in calculating the attack risk by means of grey system theory. Finally, the bi-level model is transformed into a tractable single-level problem by using a linearization method and the Karush–Kuhn–Tucker optimality conditions. Numerical case studies are performed in a real UPN to verify the effectiveness and superiority of our proposed method.
- 31 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (5) , 3708-3721
Vulnerable Node Identification for Urban Power Networks Under Deliberate Attacks With Incomplete Grid Information
From the perspective of attacker, the target urban power system (UPN) is not fully observable, especially for urban cables placed underground, posing great challenges for making attack decisions. To this end, this paper proposes an attack strategy to identify vulnerable nodes for UPN with incomplete grid information. First, a topology completion model for UPN is developed by utilizing the observable sign information of urban cables and knowledge-guided completion rules. Next, a bi-level mixed-integer program is established to maximize the attack risk, i.e., the node attack probability multiplied by the load loss, where the attack and defense strategies are considered and simulated in the outer and inner level, respectively. Furthermore, the influence of the completion accuracy is taken into account in calculating the attack risk by means of grey system theory. Finally, the bi-level model is transformed into a tractable single-level problem by using a linearization method and the Karush–Kuhn–Tucker optimality conditions. Numerical case studies are performed in a real UPN to verify the effectiveness and superiority of our proposed method.
- Open Access
- 1 December 2023
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 17 (24) , 5486-5497
Economic evaluation of battery energy storage system on the generation side for frequency and peak regulation considering the benefits of unit loss reduction
The indirect benefits of battery energy storage system (BESS) on the generation side participating in auxiliary service are hardly quantified in prior works. Nevertheless, the configuration of BESS could be affected by its indirect benefits. In this paper, the authors purpose a quantitative economic evaluation method of BESS considering the indirect benefits from the reduction in unit loss and the delay in investment. First, the authors complete further the cost model of BESS for frequency and peak regulation based on the whole life cycle theory. Second, the authors quantify the indirect benefits of BESS in thermal power plants based on the theory of rotor fatigue life loss and establish a benefits model that considers the unit loss reduction during frequency regulation and the delay in investment during peak regulation. Finally, the authors propose a set of indexes for economic evaluation of the thermal power plant with BESS. The simulation results show that the total benefits of BESS can be improved effectively by considering the indirect benefits from unit loss reduction and the delay in investment, proving the effectiveness of the proposed approach which can be meaningful for the future investment in BESS on the generation side.
- 1 December 2023
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 17 (24) , 5486-5497
Open AccessEconomic evaluation of battery energy storage system on the generation side for frequency and peak regulation considering the benefits of unit loss reduction
The indirect benefits of battery energy storage system (BESS) on the generation side participating in auxiliary service are hardly quantified in prior works. Nevertheless, the configuration of BESS could be affected by its indirect benefits. In this paper, the authors purpose a quantitative economic evaluation method of BESS considering the indirect benefits from the reduction in unit loss and the delay in investment. First, the authors complete further the cost model of BESS for frequency and peak regulation based on the whole life cycle theory. Second, the authors quantify the indirect benefits of BESS in thermal power plants based on the theory of rotor fatigue life loss and establish a benefits model that considers the unit loss reduction during frequency regulation and the delay in investment during peak regulation. Finally, the authors propose a set of indexes for economic evaluation of the thermal power plant with BESS. The simulation results show that the total benefits of BESS can be improved effectively by considering the indirect benefits from unit loss reduction and the delay in investment, proving the effectiveness of the proposed approach which can be meaningful for the future investment in BESS on the generation side.
- Open Access
- 23 November 2022
- Published by Wiley
Economic Evaluation of BESS on the Generation Side for Frequency and Peak Regulation Considering the Benefits of Unit Loss Reduction
The indirect benefits of battery energy storage system (BESS) on the generation side participating in auxiliary service are hardly quantified in prior works. Nevertheless, the configuration of BESS could be affected by its indirect benefits. In this paper, we purpose a quantitative economic evaluation method of BESS considering the indirect benefits from the reduction in unit loss and the delay in investment. First, we complete further the cost model of BESS for frequency and peak regulation based on the whole life cycle theory. Second, we quantify the indirect benefits of BESS in thermal power plants based on the theory of rotor fatigue life loss and establish a benefits model that considers the unit loss reduction during frequency regulation and the delay in investment during peak regulation. Finally, we propose a set of indexes for economic evaluation of the thermal power plant with BESS. The simulation results show that the total benefits of BESS can be improved effectively by considering the indirect benefits from unit loss reduction and the delay in investment, proving the effectiveness of the proposed approach which can be meaningful for the future investment in BESS on the generation side.
- 23 November 2022
- Published by Wiley
Open AccessEconomic Evaluation of BESS on the Generation Side for Frequency and Peak Regulation Considering the Benefits of Unit Loss Reduction
The indirect benefits of battery energy storage system (BESS) on the generation side participating in auxiliary service are hardly quantified in prior works. Nevertheless, the configuration of BESS could be affected by its indirect benefits. In this paper, we purpose a quantitative economic evaluation method of BESS considering the indirect benefits from the reduction in unit loss and the delay in investment. First, we complete further the cost model of BESS for frequency and peak regulation based on the whole life cycle theory. Second, we quantify the indirect benefits of BESS in thermal power plants based on the theory of rotor fatigue life loss and establish a benefits model that considers the unit loss reduction during frequency regulation and the delay in investment during peak regulation. Finally, we propose a set of indexes for economic evaluation of the thermal power plant with BESS. The simulation results show that the total benefits of BESS can be improved effectively by considering the indirect benefits from unit loss reduction and the delay in investment, proving the effectiveness of the proposed approach which can be meaningful for the future investment in BESS on the generation side.