Xiwen Feng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xiwen Feng has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Zhaosong Fang
5 shared publicationsJingting Sun
2 shared publications- Zhaosong Fang
School of Civil Engineering and Transportation, Guangzhou University, Guangzhou, China
2 shared publications - Zhimin Zheng
Guangzhou University
2 shared publications Baizhan Li
1 shared publicationCui Li
1 shared publication
Latest Publications
- 27 March 2025
- Published by Elsevier in Building and Environment
- Vol. 277
Analysis of the adaptive thermal comfort of the children in outdoor spaces: Case study in Guangzhou
- 27 March 2025
- Published by Elsevier in Building and Environment
- Vol. 277
Analysis of the adaptive thermal comfort of the children in outdoor spaces: Case study in Guangzhou
- 5 March 2024
- Published by Elsevier in Building and Environment
- Vol. 254
Thermal network model for anisotropic heat transfer in 3D printed complex geometry structures
- 5 March 2024
- Published by Elsevier in Building and Environment
- Vol. 254
Thermal network model for anisotropic heat transfer in 3D printed complex geometry structures
- 24 February 2023
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 188
Investigating an accurate method for measuring the outdoor mean radiation temperature
- 24 February 2023
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 188
Investigating an accurate method for measuring the outdoor mean radiation temperature
- 22 December 2022
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 32 (5) , 928-943
Studying occupant’s heat exposure and thermal comfort in the kitchen through full-scale experiments and CFD simulations
This study investigated kitchen heat exposure and thermal comfort through full-scale experiments and computational fluid dynamics (CFD) simulations. Experiments were conducted in a kitchen-style climate chamber with three stove conditions, three exhaust flowrates of range hood, three external conditions and three makeup air sources. CFD simulations were conducted accordingly to explore more nuances aspects of kitchen thermal environment. The experimental results showed that as the existence of a high-temperature stove, the air temperatures around the cooking staff, the net thermal radiations and local skin temperatures at exposed body parts increased significantly during the cooking period. External conditions and the makeup air source can significantly affect thermal distributions across the kitchen space and the heat exposures around the cooking staff. By adding partitions, using induction cooktops, and turning on the kitchen air conditioner can help to reduce cooking staff’s heat exposure from the gas-burning stove. The CFD simulations were consistent with the measured experimental results. The heat exposure in the cooking zone is shown to be dominated by horizontal thermal asymmetry. The occupants’ thermal comfort in the kitchen can be improved if the makeup air source came from the cooler side with a higher flowrate of range hood.
- 22 December 2022
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 32 (5) , 928-943
Studying occupant’s heat exposure and thermal comfort in the kitchen through full-scale experiments and CFD simulations
This study investigated kitchen heat exposure and thermal comfort through full-scale experiments and computational fluid dynamics (CFD) simulations. Experiments were conducted in a kitchen-style climate chamber with three stove conditions, three exhaust flowrates of range hood, three external conditions and three makeup air sources. CFD simulations were conducted accordingly to explore more nuances aspects of kitchen thermal environment. The experimental results showed that as the existence of a high-temperature stove, the air temperatures around the cooking staff, the net thermal radiations and local skin temperatures at exposed body parts increased significantly during the cooking period. External conditions and the makeup air source can significantly affect thermal distributions across the kitchen space and the heat exposures around the cooking staff. By adding partitions, using induction cooktops, and turning on the kitchen air conditioner can help to reduce cooking staff’s heat exposure from the gas-burning stove. The CFD simulations were consistent with the measured experimental results. The heat exposure in the cooking zone is shown to be dominated by horizontal thermal asymmetry. The occupants’ thermal comfort in the kitchen can be improved if the makeup air source came from the cooler side with a higher flowrate of range hood.
- 25 November 2022
- Published by Elsevier in Building and Environment
- Vol. 228
STMRT: A simple tree canopy radiative transfer model for outdoor mean radiant temperature
- 25 November 2022
- Published by Elsevier in Building and Environment
- Vol. 228
STMRT: A simple tree canopy radiative transfer model for outdoor mean radiant temperature
- 2 February 2022
- Published by Elsevier in Sustainable Cities and Society
- Vol. 80, 103752
Experimental Investigation of Heat Transfer Performance of a Finned-Tube Heat Exchanger under Frosting Conditions
- 2 February 2022
- Published by Elsevier in Sustainable Cities and Society
- Vol. 80, 103752
Experimental Investigation of Heat Transfer Performance of a Finned-Tube Heat Exchanger under Frosting Conditions
- 22 August 2018
- Published by Taylor & Francis in Experimental Heat Transfer
- Vol. 32 (3) , 267-283
Experimental study on performance optimization of air source heat pump using DOE method
ASHP system is extensively applied to maintain indoor thermal environment but contributes to high building energy consumption. Better energy efficiency is possible through cooling performance improvements. This study investigates, using full-scale experiments, the cooling performance of ASHP. In the series of experiments, we vary the major influencing factors—evaporator inlet air temperature, air velocity, and compressor frequency and measured their impacts on response variables that include cooling capacity, compressor power, and the COP. The design of experiment (DOE) approach is used to plan and analyze the experiments. The results show that cooling capacity of ASHP system significantly increases with the rising evaporator inlet air temperature, air velocity, and compressor frequency. However, because of increasing fan and compressor power with rising air velocity and compressor frequency, COP dramatically decrease. Finally, the study of develop a simple predictive model for assessing the COP of ASHP. Comparing with the predicted and experimental results shows an agreement within 10% deviation, which indicates the suitability of the prediction model. Therefore, a predictive model can help system operators to set the optimal design parameters for achieving optimal COP performance of ASHP system.
- 22 August 2018
- Published by Taylor & Francis in Experimental Heat Transfer
- Vol. 32 (3) , 267-283
Experimental study on performance optimization of air source heat pump using DOE method
ASHP system is extensively applied to maintain indoor thermal environment but contributes to high building energy consumption. Better energy efficiency is possible through cooling performance improvements. This study investigates, using full-scale experiments, the cooling performance of ASHP. In the series of experiments, we vary the major influencing factors—evaporator inlet air temperature, air velocity, and compressor frequency and measured their impacts on response variables that include cooling capacity, compressor power, and the COP. The design of experiment (DOE) approach is used to plan and analyze the experiments. The results show that cooling capacity of ASHP system significantly increases with the rising evaporator inlet air temperature, air velocity, and compressor frequency. However, because of increasing fan and compressor power with rising air velocity and compressor frequency, COP dramatically decrease. Finally, the study of develop a simple predictive model for assessing the COP of ASHP. Comparing with the predicted and experimental results shows an agreement within 10% deviation, which indicates the suitability of the prediction model. Therefore, a predictive model can help system operators to set the optimal design parameters for achieving optimal COP performance of ASHP system.