Nicolas Szabo-Fresnais
Nicolas Szabo-Fresnais has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Frederic Maxime Vaz
Laboratory Genetic Metabolic Diseases, Amsterdam UMC Location University of Amsterdam, Amsterdam, the Netherlands
2 shared publications - Joseph J. Orsini
Laboratory of Human Genetics, Wadsworth Center, New York State Department of Health, Albany, NY 12237, USA
2 shared publications - Michael H. Gelb
Department of Chemistry and Biochemistry, University of Washington, Seattle, WA, 98195, USA
2 shared publications - Monica Martin
Wadsworth Center, New York State Department of Health, Newborn Screening Program, David Axelrod Institute, 120 New Scotland Ave., Albany, NY 12201, USA
2 shared publications - Adrienne Manning
Connecticut Department of Public Health, Katherine A. Kelley Public Health Laboratory, Rocky Hill, CT 06067, USA
1 shared publication - Alberto Burlina
Division of Inherited Metabolic Diseases, University Hospital of Padua, Padua, Italy
1 shared publication
Latest Publications
- 20 October 2025
- Published by Springer Nature
- p. 307-313
Update on Newborn Screening for Cerebrotendinous Xanthomatosis (CTX)
- 20 October 2025
- Published by Springer Nature
- p. 307-313
Update on Newborn Screening for Cerebrotendinous Xanthomatosis (CTX)
- Open Access
- 28 November 2022
- Published by MDPI AG in International Journal of Neonatal Screening
- Vol. 8 (4) , 62
Liquid Chromatography–Tandem Mass Spectrometry in Newborn Screening Laboratories
Tandem mass spectrometry (MS/MS) is the most universal platform currently available for the analysis of enzymatic activities and biomarkers in dried blood spots (DBS) for applications in newborn screening (NBS). Among the MS/MS applications in NBS, the most common is flow-injection analysis (FIA-) MS/MS, where the sample is introduced as a bolus injection into the mass spectrometer without the prior fractionation of analytes. Liquid chromatography combined with MS/MS (LC-MS/MS) has been employed for second-tier tests to reduce the false-positive rate associated with several nonspecific screening markers, beginning two decades ago. More recently, LC-MS/MS has been applied to primary screening for new conditions for which FIA-MS/MS or other methods, including genomic screening, are not yet adequate. In addition to providing a list of the currently used LC-MS/MS-based assays for NBS, the authors share their experience regarding the maintenance requirements of LC-MS/MS vs. FIA-MS/MS systems. The consensus is that the maintenance of LC-MS/MS and FIA-MS/MS instrumentation is similar, and LC-MS/MS has the advantage of allowing for a larger number of diseases to be screened for in a multiplex, cost-effective fashion with a high throughput and an adequate turnaround time.
- 28 November 2022
- Published by MDPI AG in International Journal of Neonatal Screening
- Vol. 8 (4) , 62
Open AccessLiquid Chromatography–Tandem Mass Spectrometry in Newborn Screening Laboratories
Tandem mass spectrometry (MS/MS) is the most universal platform currently available for the analysis of enzymatic activities and biomarkers in dried blood spots (DBS) for applications in newborn screening (NBS). Among the MS/MS applications in NBS, the most common is flow-injection analysis (FIA-) MS/MS, where the sample is introduced as a bolus injection into the mass spectrometer without the prior fractionation of analytes. Liquid chromatography combined with MS/MS (LC-MS/MS) has been employed for second-tier tests to reduce the false-positive rate associated with several nonspecific screening markers, beginning two decades ago. More recently, LC-MS/MS has been applied to primary screening for new conditions for which FIA-MS/MS or other methods, including genomic screening, are not yet adequate. In addition to providing a list of the currently used LC-MS/MS-based assays for NBS, the authors share their experience regarding the maintenance requirements of LC-MS/MS vs. FIA-MS/MS systems. The consensus is that the maintenance of LC-MS/MS and FIA-MS/MS instrumentation is similar, and LC-MS/MS has the advantage of allowing for a larger number of diseases to be screened for in a multiplex, cost-effective fashion with a high throughput and an adequate turnaround time.