Mohammad Ahmadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohammad Ahmadi has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Burkhard Claus Wuensche
School of Computer Science, University of Auckland, Auckland, New Zealand
4 shared publications - Mark Billinghurst
Auckland Bioengineering Institute, The University of Auckland
4 shared publications - Samantha W. Michalka
Department of Computational Neuroscience and Engineering, Olin College of Engineering, Needham, MA 02492, USA
3 shared publications - Alexander Sumich
Department of Psychology Nottingham Trent University Nottingham UK
2 shared publications - Huidong Bai
Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
2 shared publications - Marzieh Ahmadi Najafabadi
Department of Science, Ontario Institute of Technology, Oshawa, ON L1G0C5, Canada
2 shared publications
Latest Publications
- Open Access
- 19 April 2024
- Published by MDPI AG in Multimodal Technologies and Interaction
- Vol. 8 (4) , 34
EEG, Pupil Dilations, and Other Physiological Measures of Working Memory Load in the Sternberg Task
Recent evidence shows that physiological cues, such as pupil dilation (PD), heart rate (HR), skin conductivity (SC), and electroencephalography (EEG), can indicate cognitive load (CL) in users while performing tasks. This paper aims to investigate physiological (multimodal) measurement of CL in a Sternberg memory task as the difficulty level increases in both maintenance and probe phases. For this purpose, we designed a Sternberg memory test with four levels of difficulty determined by the number of letters in the words that need to be remembered. Our behavioral performance results show that the CL of the task is related to the number of letters in non-semantic words, which confirms that this task serves as an appropriate metric of CL (the task difficulty increases as the number of letters in words increases). We were interested in investigating the suitability of multimodal physiological measures as correlates of four CL levels for both the maintenance and probe phases in the Sternberg memory task. Our motivation was to: (1) design and create four levels of task difficulty with a gradual increase in CL rather than just high and low CL, (2) use the Sternberg test as our test bed, (3) explore both the maintenance and probe phases for measurement of CL, and (4) explore the correlation of physiological cues (PD, HR, SC, EEG) with CL in both phases. Testing with the system, we found that for both the maintenance and probe phases, there was a significant positive linear relationship between average baseline corrected PD and CL. We also observed that the average baseline corrected SC showed significant increases as the number of letters in the words increased for both the maintenance and probe phases. However, the HR analysis did not show any correlation with an increase in CL in either of the maintenance or probe phases. An additional analysis was conducted to investigate the correlation of these physiological signals for high (seven-letter words) versus low (four-letter words) CL loads. Our EEG analysis for the maintenance phase found significant positive linear relationships between the power spectral density (PSD) and CL for the upper alpha bands in the centrotemporal, frontal, and occipitoparietal regions of the brain and significant positive linear relationships between the PSD and CL for the lower alpha band in the frontal and occipitoparietal regions. However, our EEG analysis of the probe phase did not show any linear relationship between the PSD and CL in any region. These results suggest that PD, SC, and EEG could be used as suitable metrics for the measurement of cognitive load in Sternberg memory tasks. We discuss this, limitations of the study, and directions for future work.
- 19 April 2024
- Published by MDPI AG in Multimodal Technologies and Interaction
- Vol. 8 (4) , 34
Open AccessEEG, Pupil Dilations, and Other Physiological Measures of Working Memory Load in the Sternberg Task
Recent evidence shows that physiological cues, such as pupil dilation (PD), heart rate (HR), skin conductivity (SC), and electroencephalography (EEG), can indicate cognitive load (CL) in users while performing tasks. This paper aims to investigate physiological (multimodal) measurement of CL in a Sternberg memory task as the difficulty level increases in both maintenance and probe phases. For this purpose, we designed a Sternberg memory test with four levels of difficulty determined by the number of letters in the words that need to be remembered. Our behavioral performance results show that the CL of the task is related to the number of letters in non-semantic words, which confirms that this task serves as an appropriate metric of CL (the task difficulty increases as the number of letters in words increases). We were interested in investigating the suitability of multimodal physiological measures as correlates of four CL levels for both the maintenance and probe phases in the Sternberg memory task. Our motivation was to: (1) design and create four levels of task difficulty with a gradual increase in CL rather than just high and low CL, (2) use the Sternberg test as our test bed, (3) explore both the maintenance and probe phases for measurement of CL, and (4) explore the correlation of physiological cues (PD, HR, SC, EEG) with CL in both phases. Testing with the system, we found that for both the maintenance and probe phases, there was a significant positive linear relationship between average baseline corrected PD and CL. We also observed that the average baseline corrected SC showed significant increases as the number of letters in the words increased for both the maintenance and probe phases. However, the HR analysis did not show any correlation with an increase in CL in either of the maintenance or probe phases. An additional analysis was conducted to investigate the correlation of these physiological signals for high (seven-letter words) versus low (four-letter words) CL loads. Our EEG analysis for the maintenance phase found significant positive linear relationships between the power spectral density (PSD) and CL for the upper alpha bands in the centrotemporal, frontal, and occipitoparietal regions of the brain and significant positive linear relationships between the PSD and CL for the lower alpha band in the frontal and occipitoparietal regions. However, our EEG analysis of the probe phase did not show any linear relationship between the PSD and CL in any region. These results suggest that PD, SC, and EEG could be used as suitable metrics for the measurement of cognitive load in Sternberg memory tasks. We discuss this, limitations of the study, and directions for future work.
- Open Access
- 9 October 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-11
Cognitive Load Measurement with Physiological Sensors in Virtual Reality during Physical Activity
Many Virtual Reality (VR) experiences, such as learning tools, would benefit from utilising mental states such as cognitive load. Increases in cognitive load (CL) are often reflected in the alteration of physiological responses, such as pupil dilation (PD), electrodermal cctivity (EDA), heart rate (HR), and electroencephalography (EEG). However, the relationship between these physiological responses and cognitive load are usually measured while participants sit in front of a computer screen, whereas VR environments often require a high degree of physical movement. This physical activity can affect the measured signals, making it unclear how suitable these measures are for use in interactive Virtual Reality (VR). We investigate the suitability of four physiological measures as correlates of cognitive load in interactive VR. Suitable measures must be robust enough to allow the learner to move within VR and be temporally responsive enough to be a useful metric for adaptation. We recorded PD, EDA, HR, and EEG data from nineteen participants during a sequence memory task at varying levels of cognitive load using VR, while in the standing position and using their dominant arm to play a game. We observed significant linear relationships between cognitive load and PD, EDA, and EEG frequency band power, but not HR. PD showed the most reliable relationship but has a slower response rate than EEG. Our results suggest the potential for use of PD, EDA, and EEG in this type of interactive VR environment, but additional studies will be needed to assess feasibility under conditions of greater movement.
- 9 October 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-11
Open AccessCognitive Load Measurement with Physiological Sensors in Virtual Reality during Physical Activity
Many Virtual Reality (VR) experiences, such as learning tools, would benefit from utilising mental states such as cognitive load. Increases in cognitive load (CL) are often reflected in the alteration of physiological responses, such as pupil dilation (PD), electrodermal cctivity (EDA), heart rate (HR), and electroencephalography (EEG). However, the relationship between these physiological responses and cognitive load are usually measured while participants sit in front of a computer screen, whereas VR environments often require a high degree of physical movement. This physical activity can affect the measured signals, making it unclear how suitable these measures are for use in interactive Virtual Reality (VR). We investigate the suitability of four physiological measures as correlates of cognitive load in interactive VR. Suitable measures must be robust enough to allow the learner to move within VR and be temporally responsive enough to be a useful metric for adaptation. We recorded PD, EDA, HR, and EEG data from nineteen participants during a sequence memory task at varying levels of cognitive load using VR, while in the standing position and using their dominant arm to play a game. We observed significant linear relationships between cognitive load and PD, EDA, and EEG frequency band power, but not HR. PD showed the most reliable relationship but has a slower response rate than EEG. Our results suggest the potential for use of PD, EDA, and EEG in this type of interactive VR environment, but additional studies will be needed to assess feasibility under conditions of greater movement.
- Open Access
- 9 October 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-2
Comparing Performance of Dry and Gel EEG Electrodes in VR using MI Paradigms
Brain–computer interfaces (BCIs) are an emerging technology with numerous applications. Electroencephalogram (EEG) motor imagery (MI) is among the most common BCI paradigms and has been used extensively in healthcare applications such as post-stroke rehabilitation. Using a Virtual Reality (VR) game, Push Me, we conducted a pilot study to compare MI accuracy with Gel or active-dry EEG electrodes. The motivation was to (1) investigate the MI paradigm in a VR environment and (2) compare MI accuracy using active dry and gel electrodes with different Machine Learning (ML) classifications (SVM, KNN and RF). The results indicate that while gel-based electrodes, in combination with SVM, achieved the highest accuracy, dry electrode EEG caps achieved similar outcomes, especially with SVM and KNN models.
- 9 October 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-2
Open AccessComparing Performance of Dry and Gel EEG Electrodes in VR using MI Paradigms
Brain–computer interfaces (BCIs) are an emerging technology with numerous applications. Electroencephalogram (EEG) motor imagery (MI) is among the most common BCI paradigms and has been used extensively in healthcare applications such as post-stroke rehabilitation. Using a Virtual Reality (VR) game, Push Me, we conducted a pilot study to compare MI accuracy with Gel or active-dry EEG electrodes. The motivation was to (1) investigate the MI paradigm in a VR environment and (2) compare MI accuracy using active dry and gel electrodes with different Machine Learning (ML) classifications (SVM, KNN and RF). The results indicate that while gel-based electrodes, in combination with SVM, achieved the highest accuracy, dry electrode EEG caps achieved similar outcomes, especially with SVM and KNN models.
- Open Access
- 29 November 2022
- Published by Association for Computing Machinery (ACM)
- p. 1-2
PlayMeBack - Cognitive Load Measurement using Different Physiological Cues in a VR Game
We present a Virtual Reality (VR) game, PlayMeBack, to investigate cognitive load measurement in interactive VR environments using pupil dilation, Galvanic Skin Response (GSR), Electroencephalogram (EEG) and Heart Rate (HR). The user is shown different patterns of tiles lighting up and is asked to replay the pattern back pressing the tiles in the same sequence they lit up. The task difficulty depends on the length of the observed pattern (3-6 keys). This task is designed to explore the effect of cognitive load on physiological cues, and if pupil dilation, EEG, GSR and HR can be used as measures of cognitive load.
- 29 November 2022
- Published by Association for Computing Machinery (ACM)
- p. 1-2
Open AccessPlayMeBack - Cognitive Load Measurement using Different Physiological Cues in a VR Game
We present a Virtual Reality (VR) game, PlayMeBack, to investigate cognitive load measurement in interactive VR environments using pupil dilation, Galvanic Skin Response (GSR), Electroencephalogram (EEG) and Heart Rate (HR). The user is shown different patterns of tiles lighting up and is asked to replay the pattern back pressing the tiles in the same sequence they lit up. The task difficulty depends on the length of the observed pattern (3-6 keys). This task is designed to explore the effect of cognitive load on physiological cues, and if pupil dilation, EEG, GSR and HR can be used as measures of cognitive load.