Hai Xu
Hai Xu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Haiwen Yuan
Beihang University
10 shared publications - Jianxun Lv
Beihang University
9 shared publications - Chengxin Liu
School of Automation Science and Electrical Engineering, Beihang University, Beijing, China
7 shared publications - Jinmeng Li
School of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
5 shared publications - Penghui Zhao
School of Automation Science and Electrical Engineering, Beihang University, Beijing, China
4 shared publications - Zhangwei Wang
School of Automation Science and Electrical Engineering, Beihang University, Beijing, China
4 shared publications
Latest Publications
- Open Access
- 4 July 2026
- Published by Elsevier in SSRN Electronic Journal
Electromagnetic–thermal co-design and dynamic control of a high-power induction heating system for ammonium bisulfate deposit treatment
Rapid removal of ammonium bisulfate (ABS) deposits requires both high-efficiency electromagnetic heating and stable thermal regulation under continuously varying operating conditions. To address this challenge, this paper proposes a resonant ablation equipment (RAE) integrating electromagnetic-thermal coupling analysis, load configuration optimization, and dynamic resonance control. A discrete electromagnetic–thermal model is first established to reveal the relationship between the magnetic energy distribution and heat generation, on which a multi-objective optimization strategy is subsequently developed to determine the optimal annular load configuration. Furthermore, a parameter-dynamic controller that combines dynamic resonance tracking (DRT) and automatic temperature control (ATC) is proposed to maintain resonance and suppress thermal inertia during rapid heating. Both theoretical and experimental results demonstrate that optimized annular loads consistently outperform conventional disk loads and that different optimization objectives yield distinct optimal annular configurations. The fastest-heating configuration achieves an average heating rate of 3.878 °C/s, corresponding to 4.02 times that of a conventional disk load, while the efficiencies of all optimized annular configurations are significantly higher than that of the conventional disk load. Moreover, the proposed controller reduces the thermal response delay by approximately 10 s while maintaining stable zero-voltage switching and resonant operation. The proposed framework establishes a complete model-driven methodology for electromagnetic heating systems and offers a novel solution for rapid, controllable removal of ABS deposits.
- 4 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessElectromagnetic–thermal co-design and dynamic control of a high-power induction heating system for ammonium bisulfate deposit treatment
Rapid removal of ammonium bisulfate (ABS) deposits requires both high-efficiency electromagnetic heating and stable thermal regulation under continuously varying operating conditions. To address this challenge, this paper proposes a resonant ablation equipment (RAE) integrating electromagnetic-thermal coupling analysis, load configuration optimization, and dynamic resonance control. A discrete electromagnetic–thermal model is first established to reveal the relationship between the magnetic energy distribution and heat generation, on which a multi-objective optimization strategy is subsequently developed to determine the optimal annular load configuration. Furthermore, a parameter-dynamic controller that combines dynamic resonance tracking (DRT) and automatic temperature control (ATC) is proposed to maintain resonance and suppress thermal inertia during rapid heating. Both theoretical and experimental results demonstrate that optimized annular loads consistently outperform conventional disk loads and that different optimization objectives yield distinct optimal annular configurations. The fastest-heating configuration achieves an average heating rate of 3.878 °C/s, corresponding to 4.02 times that of a conventional disk load, while the efficiencies of all optimized annular configurations are significantly higher than that of the conventional disk load. Moreover, the proposed controller reduces the thermal response delay by approximately 10 s while maintaining stable zero-voltage switching and resonant operation. The proposed framework establishes a complete model-driven methodology for electromagnetic heating systems and offers a novel solution for rapid, controllable removal of ABS deposits.
- 6 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
PCB Fault Identification With Multiscale Feature Fusion and Heat Source Attention Based on Multimodal Infrared Thermal Imaging
The widespread use of complex-structured printed circuit boards (PCBs) in high-tech equipment has increased reliability and fault detection demand. Low resolution and significant differences in infrared thermal imaging feature scales limit the application in PCB fault identification using existing deep learning models. A PCB fault identification framework based on multimodal infrared thermal imaging multiscale feature fusion and heat source attention is proposed to address this challenge. The framework significantly enhances the accuracy and robustness of fault detection by encoding multiscale features from multimodal infrared thermal images. In the proposed framework, the input images are extended into RST multimodal infrared thermal images, which include the spatiotemporal variation rate of the temperature field, enriching the thermal image feature. Additionally, the framework integrates feature pyramid networks (FPN) and heat source attention (HSA) modules into the encoding network, improving the ability to express fault-related features. Experimental validation on a two-phase drive circuit demonstrates that the proposed framework improves classification accuracy by 4.0% compared to existing deep convolutional neural networks, showing high robustness against focus blur and pixel failures. More importantly, the framework accurately detects faults at early stages. This study improves the accuracy and efficiency of PCB fault identification and provides technical support for the reliability monitoring of complex electronic equipment.
- 6 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
PCB Fault Identification With Multiscale Feature Fusion and Heat Source Attention Based on Multimodal Infrared Thermal Imaging
The widespread use of complex-structured printed circuit boards (PCBs) in high-tech equipment has increased reliability and fault detection demand. Low resolution and significant differences in infrared thermal imaging feature scales limit the application in PCB fault identification using existing deep learning models. A PCB fault identification framework based on multimodal infrared thermal imaging multiscale feature fusion and heat source attention is proposed to address this challenge. The framework significantly enhances the accuracy and robustness of fault detection by encoding multiscale features from multimodal infrared thermal images. In the proposed framework, the input images are extended into RST multimodal infrared thermal images, which include the spatiotemporal variation rate of the temperature field, enriching the thermal image feature. Additionally, the framework integrates feature pyramid networks (FPN) and heat source attention (HSA) modules into the encoding network, improving the ability to express fault-related features. Experimental validation on a two-phase drive circuit demonstrates that the proposed framework improves classification accuracy by 4.0% compared to existing deep convolutional neural networks, showing high robustness against focus blur and pixel failures. More importantly, the framework accurately detects faults at early stages. This study improves the accuracy and efficiency of PCB fault identification and provides technical support for the reliability monitoring of complex electronic equipment.
- 25 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
A Noncontact PCB Multifault Diagnosis Algorithm Based on Scalar Magnetic Field Fusion Feature and Transformer Architecture
Non-contact printed circuit board (PCB) fault diagnosis has been widely applied in PCB detection and maintenance. Due to objective factors such as visual blind spots, low-loss circuit structure design, and frequency insensitivity, traditional algorithms based on visual and temperature features are limited in practice. Therefore, the algorithm based on electromagnetic features containing rich physical connotations and prominent frequency features has received attention in PCB fault diagnosis. Based on the basic principles of electromagnetic physics and PCB fault relationship, this article proposes a scalar magnetic field source feature and further improves feature performance by adding topological relationships of multi-faults to generate the fusion feature. The backbone of the PCB diagnosis model is established on the Transformer architecture, effectively utilizing self-attention and parallel computing mechanisms to explore the inner correlation between each group feature. The paper provides a new non-contact PCB fault diagnosis solution that enriches existing methods. Besides, through actual experiments setting up multi-fault PCBs, the feasibility of our process is proved based on the proposed features and models. The specific multiple indicators Overall Precision (OP), Per Class Precision (CP), Overall Recall (OR), Per Class Recall (CR), Overall F1 Measure (OF1), Per Class F1 Measure (CF1), Accuracy (ACC), Mean Average Precision (mAP) are 98.55%, 94.89%, 98.55%, 95.11%, 98.55%, 95.32%, 96.01%, and 97.27%.
- 25 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
A Noncontact PCB Multifault Diagnosis Algorithm Based on Scalar Magnetic Field Fusion Feature and Transformer Architecture
Non-contact printed circuit board (PCB) fault diagnosis has been widely applied in PCB detection and maintenance. Due to objective factors such as visual blind spots, low-loss circuit structure design, and frequency insensitivity, traditional algorithms based on visual and temperature features are limited in practice. Therefore, the algorithm based on electromagnetic features containing rich physical connotations and prominent frequency features has received attention in PCB fault diagnosis. Based on the basic principles of electromagnetic physics and PCB fault relationship, this article proposes a scalar magnetic field source feature and further improves feature performance by adding topological relationships of multi-faults to generate the fusion feature. The backbone of the PCB diagnosis model is established on the Transformer architecture, effectively utilizing self-attention and parallel computing mechanisms to explore the inner correlation between each group feature. The paper provides a new non-contact PCB fault diagnosis solution that enriches existing methods. Besides, through actual experiments setting up multi-fault PCBs, the feasibility of our process is proved based on the proposed features and models. The specific multiple indicators Overall Precision (OP), Per Class Precision (CP), Overall Recall (OR), Per Class Recall (CR), Overall F1 Measure (OF1), Per Class F1 Measure (CF1), Accuracy (ACC), Mean Average Precision (mAP) are 98.55%, 94.89%, 98.55%, 95.11%, 98.55%, 95.32%, 96.01%, and 97.27%.
- 8 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
Anomaly Detection and Fault Classification of Printed Circuit Boards Based on Multimodal Features of the Infrared Thermal Imaging
A heightened demand for improved printed circuit board (PCB) fault detection arises with the increasing integration and enhanced functionality of PCBs. Traditional visible light image analysis demonstrates accuracy and safety advantages in nonintrusive detection. However, it exhibits limitations in detecting obscured faults or lack of visible defects. The study proposes a fault detection framework based on infrared thermal imaging, aiming to enhance the practicality and engineering efficiency of PCB fault detection. This article introduces an infrared-thermography-based framework for anomaly detection and fault classification of PCBs. The framework encompasses preprocessing infrared thermal images, extraction of multimodal feature vectors (MMFVs), density-based anomaly detection (DAD), and fault classification based on deviation matrix clustering. The framework extracts multimodal features from the residual temperature scalar fields and residual temperature gradient vector fields, using multiscale detection of global and local images for fault classification. Experimental validation on a two-phase drive (TPD) circuit illustrates a significant enhancement in PCB anomaly detection and fault classification accuracy compared with existing feature extraction techniques. This research provides an innovative and practical PCB manufacturing and maintenance tool, effectively elevating anomaly detection accuracy and operational feasibility in engineering practices.
- 8 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
Anomaly Detection and Fault Classification of Printed Circuit Boards Based on Multimodal Features of the Infrared Thermal Imaging
A heightened demand for improved printed circuit board (PCB) fault detection arises with the increasing integration and enhanced functionality of PCBs. Traditional visible light image analysis demonstrates accuracy and safety advantages in nonintrusive detection. However, it exhibits limitations in detecting obscured faults or lack of visible defects. The study proposes a fault detection framework based on infrared thermal imaging, aiming to enhance the practicality and engineering efficiency of PCB fault detection. This article introduces an infrared-thermography-based framework for anomaly detection and fault classification of PCBs. The framework encompasses preprocessing infrared thermal images, extraction of multimodal feature vectors (MMFVs), density-based anomaly detection (DAD), and fault classification based on deviation matrix clustering. The framework extracts multimodal features from the residual temperature scalar fields and residual temperature gradient vector fields, using multiscale detection of global and local images for fault classification. Experimental validation on a two-phase drive (TPD) circuit illustrates a significant enhancement in PCB anomaly detection and fault classification accuracy compared with existing feature extraction techniques. This research provides an innovative and practical PCB manufacturing and maintenance tool, effectively elevating anomaly detection accuracy and operational feasibility in engineering practices.
- 21 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (7) , 10892-10903
Decoupling and Reconstruction of Low-Quality Temperature Fields of Printed Circuit Boards
The increasing integration of electronic components and the complexity of printed circuit boards (PCBs) necessitate more efficient, accurate, and safe PCB inspection requirements. Using infrared thermography instruments to measure temperature fields to identify PCB faults has the advantage of non-intrusive detection compared to the traditional electrical measurement method. This paper establishes a thermal model of PCBs to overcome the mutual interference of heating components and enhance the quality of thermal images. A method for solving the power of heating components and decoupling the PCB temperature field using Green’s functions is proposed. Further, a robust and accuracy-optimized reconstruction method is proposed to reconstruct low-quality temperature fields, including denoising temperature fields with high-level noise and recovering incomplete temperature fields. The study validates the proposed temperature field decoupling method by analyzing a buck DC/DC converter, demonstrating its ability to accurately determine the thermal power of components and separate the temperature fields of different components. The proposed method uses partial temperature measurement points to estimate temperature fields, effectively suppressing the high-level Gaussian and salt-and-pepper noise in thermal images and restoring incomplete thermal images. The research results promise to expand the practical applications of online PCB testing technology and improve fault diagnosis.
- 21 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (7) , 10892-10903
Decoupling and Reconstruction of Low-Quality Temperature Fields of Printed Circuit Boards
The increasing integration of electronic components and the complexity of printed circuit boards (PCBs) necessitate more efficient, accurate, and safe PCB inspection requirements. Using infrared thermography instruments to measure temperature fields to identify PCB faults has the advantage of non-intrusive detection compared to the traditional electrical measurement method. This paper establishes a thermal model of PCBs to overcome the mutual interference of heating components and enhance the quality of thermal images. A method for solving the power of heating components and decoupling the PCB temperature field using Green’s functions is proposed. Further, a robust and accuracy-optimized reconstruction method is proposed to reconstruct low-quality temperature fields, including denoising temperature fields with high-level noise and recovering incomplete temperature fields. The study validates the proposed temperature field decoupling method by analyzing a buck DC/DC converter, demonstrating its ability to accurately determine the thermal power of components and separate the temperature fields of different components. The proposed method uses partial temperature measurement points to estimate temperature fields, effectively suppressing the high-level Gaussian and salt-and-pepper noise in thermal images and restoring incomplete thermal images. The research results promise to expand the practical applications of online PCB testing technology and improve fault diagnosis.
- 30 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
A Calculation Method for Reconstructing Radiation State of PCB Using Known Magnetic Field Amplitude Information
Using magnetic field data to characterize the state of radio frequency (RF) printed circuit board (PCB) has been widely used in circuit state detection and fault identification. However, it may be difficult to measure the complete state of magnetic field radiation, so the characteristics of PCB may be challenging to establish, which makes the calculation method of reconstructing other radiation information of PCB with existing magnetic field information urgently needed. Based on the basic radiation principle of the electromagnetic field, we propose an algorithm that has advantages in reconstructing the magnetic field radiation state, in which the new single-layer iterative (NSLI) algorithm provides a more reasonable optimization range and field-source conversion matrix for the hybrid particle swarm optimization (HYPSO) algorithm, and converts the inverse problem of the large matrix into a forward optimization problem, further ensuring the accuracy and objectivity of the algorithm. According to the known magnetic field amplitude, this paper uses a two-phase drive circuit at 50 MHz frequency as a device under testing (DUT) to verify the proposed algorithm’s feasibility by reconstructing the complete three-dimensional magnetic field component radiated from the DUT and estimating the unknown magnetic field amplitude on the predicted plane. The specific experimental data shows that when the magnetic field amplitude is known, the relative errors of the reconstructed magnetic field on the x , y , and z components are 1.9%, 0.02%, and 0.06%. In the meantime, under the actual measurement environment with a maximum relative uncertainty of 0.59%, the relative error of the magnetic field amplitude of the unknown predicted plane is 6.15%.
- 30 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
A Calculation Method for Reconstructing Radiation State of PCB Using Known Magnetic Field Amplitude Information
Using magnetic field data to characterize the state of radio frequency (RF) printed circuit board (PCB) has been widely used in circuit state detection and fault identification. However, it may be difficult to measure the complete state of magnetic field radiation, so the characteristics of PCB may be challenging to establish, which makes the calculation method of reconstructing other radiation information of PCB with existing magnetic field information urgently needed. Based on the basic radiation principle of the electromagnetic field, we propose an algorithm that has advantages in reconstructing the magnetic field radiation state, in which the new single-layer iterative (NSLI) algorithm provides a more reasonable optimization range and field-source conversion matrix for the hybrid particle swarm optimization (HYPSO) algorithm, and converts the inverse problem of the large matrix into a forward optimization problem, further ensuring the accuracy and objectivity of the algorithm. According to the known magnetic field amplitude, this paper uses a two-phase drive circuit at 50 MHz frequency as a device under testing (DUT) to verify the proposed algorithm’s feasibility by reconstructing the complete three-dimensional magnetic field component radiated from the DUT and estimating the unknown magnetic field amplitude on the predicted plane. The specific experimental data shows that when the magnetic field amplitude is known, the relative errors of the reconstructed magnetic field on the x , y , and z components are 1.9%, 0.02%, and 0.06%. In the meantime, under the actual measurement environment with a maximum relative uncertainty of 0.59%, the relative error of the magnetic field amplitude of the unknown predicted plane is 6.15%.
- 4 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (2) , 2122-2132
−252.8 °C Liquid Hydrogen Acoustic Emission Experiment in Simulated Aerospace Fuel Tank
With the increase of space activities, the safety detection of equipment in supercold environment becomes more and more important. However, the safety detection of equipment in liquid hydrogen environment is an unsolved worldwide problem. In this article, we present a new method to detect acoustic emission (AE) signals in liquid hydrogen environment, which can be used to confirm the safety and reliability of the equipment working in liquid hydrogen. First, the principle of mandrel-based fiber-optic ring (MBFOR) AE sensor and the corresponding demodulation method are introduced. Second, the effects of physical parameters, such as the length of the sensing fiber, the diameter and material of the mandrel, and the number of fiber winding layers on the sensor's sensitivity, are studied by experiment. Finally, the AE source localization accuracy test of the FOR AE detection system at low temperatures and the adaptability test of the proposed method in −252.8 °C liquid hydrogen are carried out. The results show that the proposed MBFOR sensor and the multichannel AE detection system can complete the defects detection of aerospace pressure vessel in liquid hydrogen. Certainly, it can be used for safety detection for other spacecraft equipment in harsh environments.
- 4 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (2) , 2122-2132
−252.8 °C Liquid Hydrogen Acoustic Emission Experiment in Simulated Aerospace Fuel Tank
With the increase of space activities, the safety detection of equipment in supercold environment becomes more and more important. However, the safety detection of equipment in liquid hydrogen environment is an unsolved worldwide problem. In this article, we present a new method to detect acoustic emission (AE) signals in liquid hydrogen environment, which can be used to confirm the safety and reliability of the equipment working in liquid hydrogen. First, the principle of mandrel-based fiber-optic ring (MBFOR) AE sensor and the corresponding demodulation method are introduced. Second, the effects of physical parameters, such as the length of the sensing fiber, the diameter and material of the mandrel, and the number of fiber winding layers on the sensor's sensitivity, are studied by experiment. Finally, the AE source localization accuracy test of the FOR AE detection system at low temperatures and the adaptability test of the proposed method in −252.8 °C liquid hydrogen are carried out. The results show that the proposed MBFOR sensor and the multichannel AE detection system can complete the defects detection of aerospace pressure vessel in liquid hydrogen. Certainly, it can be used for safety detection for other spacecraft equipment in harsh environments.
- 27 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (9) , 9909-9916
Differential Structure to Improve Performance of DC Electric Field Sensors
The electric field is an essential electromagnetic environmental parameter in designing and constructing high-voltage direct-current (HVDC) transmission lines. In this paper, a differential structure is proposed to improve the performance of the field mill sensor. Two groups of vanes with the same characteristics generate induced currents with opposite phases, and the difference operation calculates the ground electric field. We calculated the charges and induced currents and optimized the number of vanes of the sensing electrode using the simulation model. Then we designed the I/V circuit and amplifier based on the differential structure and conducted circuit simulation and sensor calibration experiments. Compared with the single input electric field sensor, the noise of the sensor with the differential structure is significantly reduced, and the sensitivity reaches 0.085 V/(kV/m). The results indicate that the field mill sensor with improved differential structure enhances the anti-interference ability and sensitivity.
- 27 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (9) , 9909-9916
Differential Structure to Improve Performance of DC Electric Field Sensors
The electric field is an essential electromagnetic environmental parameter in designing and constructing high-voltage direct-current (HVDC) transmission lines. In this paper, a differential structure is proposed to improve the performance of the field mill sensor. Two groups of vanes with the same characteristics generate induced currents with opposite phases, and the difference operation calculates the ground electric field. We calculated the charges and induced currents and optimized the number of vanes of the sensing electrode using the simulation model. Then we designed the I/V circuit and amplifier based on the differential structure and conducted circuit simulation and sensor calibration experiments. Compared with the single input electric field sensor, the noise of the sensor with the differential structure is significantly reduced, and the sensitivity reaches 0.085 V/(kV/m). The results indicate that the field mill sensor with improved differential structure enhances the anti-interference ability and sensitivity.
- Open Access
Research and Application of Energy-Efficient Management Approach for Wireless Sensor Networks
Wireless sensor networks (WSNs) are widely used in industrial applications. However, many of them have limited lifetimes, which has been a considerable constraint on their widespread use. As a typical application of WSNs, distributed measurement of the electric field under high-voltage direct-current (HVDC) transmission lines also suffers from this issue. This paper first introduces the composition of the electric-field measurement system (EFMS) and its working principle. Considering the actual power supply of the system, this paper mainly introduces the composition of the wireless sensor node (WSND) and analyzes the power consumption and potential working state transformation of the WSND, together with a comprehensive study on parameters affecting the power consumption of the wireless communication unit. Moreover, an energy-efficient scheduling approach is proposed after specially designing a working sequence and the study on system parameters. The proposed approach is verified by experiments on not only the experimental line of the national HVDC test base, but also a commercial operation HVDC transmission line with the challenge of long endurance, which is considered in this paper with a new strategy. The results show that the proposed method can greatly extend the lifetime of the WSND.
Open AccessResearch and Application of Energy-Efficient Management Approach for Wireless Sensor Networks
Wireless sensor networks (WSNs) are widely used in industrial applications. However, many of them have limited lifetimes, which has been a considerable constraint on their widespread use. As a typical application of WSNs, distributed measurement of the electric field under high-voltage direct-current (HVDC) transmission lines also suffers from this issue. This paper first introduces the composition of the electric-field measurement system (EFMS) and its working principle. Considering the actual power supply of the system, this paper mainly introduces the composition of the wireless sensor node (WSND) and analyzes the power consumption and potential working state transformation of the WSND, together with a comprehensive study on parameters affecting the power consumption of the wireless communication unit. Moreover, an energy-efficient scheduling approach is proposed after specially designing a working sequence and the study on system parameters. The proposed approach is verified by experiments on not only the experimental line of the national HVDC test base, but also a commercial operation HVDC transmission line with the challenge of long endurance, which is considered in this paper with a new strategy. The results show that the proposed method can greatly extend the lifetime of the WSND.
- 28 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. PP (00189456) , 1
A Sensor for Three-Dimensional Component Measurement of Synthetic Electric Field Vector in HVDC Transmission Lines Using Unidirectional Motion
High voltage direct current (HVDC) transmission lines have been widely used in China, and the electromagnetic effects of the synthetic electric field generated by them on the surrounding environment have attracted more and more attention. Especially when there are residential buildings around the transmission lines, the distortion of the electric field makes the research and development of synthetic electric field sensors with three-dimensional (3D) measurement capability an urgent technical demand. Based on the basic principle of the field mill electric field sensor, this paper presents a three-dimensional field mill structure to obtain the three-dimensional component of the electric field vector by using unidirectional motion. With the signal processing circuit, we realize the reading of three-dimensional electric field data. The feasibility of the proposed structure is verified by theoretical deduction analysis, numerical simulation, and prototype tests. The proposed structure provides a new scheme to solve the problems of three-dimensional synthetic electric field measurement and can enrich the existing methods.
- 28 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. PP (00189456) , 1
A Sensor for Three-Dimensional Component Measurement of Synthetic Electric Field Vector in HVDC Transmission Lines Using Unidirectional Motion
High voltage direct current (HVDC) transmission lines have been widely used in China, and the electromagnetic effects of the synthetic electric field generated by them on the surrounding environment have attracted more and more attention. Especially when there are residential buildings around the transmission lines, the distortion of the electric field makes the research and development of synthetic electric field sensors with three-dimensional (3D) measurement capability an urgent technical demand. Based on the basic principle of the field mill electric field sensor, this paper presents a three-dimensional field mill structure to obtain the three-dimensional component of the electric field vector by using unidirectional motion. With the signal processing circuit, we realize the reading of three-dimensional electric field data. The feasibility of the proposed structure is verified by theoretical deduction analysis, numerical simulation, and prototype tests. The proposed structure provides a new scheme to solve the problems of three-dimensional synthetic electric field measurement and can enrich the existing methods.