SDSubash Dulal

Subash Dulal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Subash Dulal has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    Revolutionizing Cardiology: The Role of Artificial Intelligence in Echocardiography

    by Bhanu Maturi, Subash Dulal, Suresh Babu Sayana, Atif Ibrahim, Manasa Ramakrishna, Viswanath Chinta, Ashwini Sharma, Harish Ravipati

    Background: Artificial intelligence (AI) in echocardiography represents a transformative advancement in cardiology, addressing longstanding challenges in cardiac diagnostics. Echocardiography has traditionally been limited by operator-dependent variability and subjective interpretation, which impact diagnostic reliability. This study evaluates the role of AI, particularly machine learning (ML), in enhancing the accuracy and consistency of echocardiographic image analysis and its potential to complement clinical expertise. Methods: A comprehensive review of existing literature was conducted to analyze the integration of AI into echocardiography. Key AI functionalities, such as image acquisition, standard view classification, cardiac chamber segmentation, structural quantification, and functional assessment, were assessed. Comparisons with traditional imaging modalities like computed tomography (CT), nuclear imaging, and magnetic resonance imaging (MRI) were also explored. Results: AI algorithms demonstrated expert-level accuracy in diagnosing conditions such as cardiomyopathies while reducing operator variability and enhancing diagnostic consistency. The application of ML was particularly effective in automating image analysis and minimizing human error, addressing the limitations of subjective operator expertise. Conclusions: The integration of AI into echocardiography marks a pivotal shift in cardiovascular diagnostics, offering enhanced accuracy, consistency, and reliability. By addressing operator variability and improving diagnostic performance, AI has the potential to elevate patient care and herald a new era in cardiology.


  • Open Access

    Revolutionizing Cardiology: The Role of Artificial Intelligence in Echocardiography

    by Bhanu Maturi, Subash Dulal, Atif Ibrahim, Manasa Ramakrishna, Viswanath Chinta, Navin C. Nanda, Ashwini Sharma, Harish Ravipati

    Artificial Intelligence (AI) in echocardiography represents a transformative leap in the realm of cardiology, refining diagnostic accuracy and mitigating human error. AI, often erroneously equated with robotics or automation, transcends mere mechanical operations. It encompasses the capacity of machines to emulate human decision-making processes and problem-solving abilities, augmenting rather than replacing human expertise. In echocardiography, AI has emerged as a pivotal tool, enhancing consistency and precision, elements crucial in cardiac diagnostics. Echocardiography is indispensable in the diagnosis of cardiovascular diseases, but it is traditionally hampered by operator-dependent variability and subjective interpretation. AI intervenes here, offering high-precision automation in echocardiographic analysis. This encompasses several key phases: from image acquisition and standard view classification to cardiac chamber segmentation, structural quantification, and functional assessment. AI algorithms have demonstrated expertise-level accuracy in these domains, notably in identifying cardiac conditions such as cardiomyopathies. The incorporation of AI into echocardiography tackles inherent challenges like variance in image capture and analysis. AI's prowess in machine learning (ML), a crucial subset of AI, specifically enhances image interpretation in echocardiography. This advancement is significant given echocardiography's reliance on the operator's subjective expertise, a reliance more pronounced than in other imaging modalities such as computed tomography (CT), nuclear imaging, and magnetic resonance imaging (MRI). AI technologies, through automated and consistent interpretations, promise to reshape echocardiographic diagnostics. This review delves into ML's role in augmenting echocardiographic image analysis and diagnostic performance. It also examines the existing literature, highlighting AI's value in echocardiography and its potential to elevate patient care. In summary, AI's integration into echocardiography marks a pivotal shift, offering enhanced diagnostic capabilities and heralding a new era in cardiovascular care.

  • Open Access

    Utilization of Two- and Three-Dimensional Transesophageal Echocardiography in Successfully Guiding Transcatheter Mitral Valve in Bioprosthetic Mitral Valve/Mitral Ring Implantation without Complications in Patients with Thrombus in Left Atrium/Left Atrial Appendage

    by Zeyad M. Elmarzouky, Ming-Chon Hsiung, Amr Darwish, Subash Dulal, Bhanu Maturi, Wei-Hsian Yin, Yung-Tsai Lee, Tien-Ping Tsao, Jeng Wei, Navin C. Nanda

    Background. The aim of this study is to describe, for the first time to our knowledge, the utilization of both two-dimensional (2D) and three-dimensional (3D) transesophageal echocardiography (TEE) in successfully performing transcatheter mitral valve (MV) in bioprosthetic MV/MV annulopasty ring implantation using the apical approach in 12 patients (pts) with co-existing left atrial appendage (LAA) and/or LA (left atrium) body thrombus, which is considered a contraindication for this procedure. Methods and Results. All pts were severely symptomatic with severe bioprosthetic MV stenosis/regurgitation except one with a previous MV annuloplasty ring and severe native MV stenosis. Thrombus in LAA and/or LA body was noted in all by 2D and 3DTEE. All were at high/prohibitive risk for redo operation and all refused surgery. Utilizing both 2D and 3DTEE, especially 3DTEE, guidewires and the prosthesis deployment system could be manipulated under direct vision into the LA avoiding any contact with the thrombus. The procedure was successful in all with amelioration of symptoms and no embolic or other complications over a mean follow-up of 21 months. Conclusion. Our study demonstrates the feasibility of successfully performing this procedure in pts with thrombus in LAA and/or LA body without any complications.