Shymaa S. Soliman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shymaa S. Soliman has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Amr Mohamed Mahmoud
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr El-Aini Street, Cairo 11562, Egypt
5 shared publications - Mohammed Refaat Elghobashy
Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo, Egypt
3 shared publications - Mona A. Abdel Rahman
Analytical Chemistry Department, Faculty of Pharmacy, October 6 University, October 6 City, Egypt
3 shared publications - Amira M. Kessiba
Pharmaceutical Chemistry Department, Faculty of Pharmacy, Misr International University, Cairo, Egypt
2 shared publications - Ghada AbdElHamid Sedik
Department of Analytical Chemistry Faculty of Pharmacy Cairo University Cairo Egypt
2 shared publications Hala E. Zaazaa
Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr-El Aini Street, Cairo, 11562, Egypt
2 shared publications
Latest Publications
- Open Access
- 6 November 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 37203
Complementary spectroscopic methods for simultaneous quantification of tiotropium bromide and olodaterol hydrochloride with analytical performance and environmental sustainability assessment
The development of efficient, cost-effective, and environmentally friendly analytical methods for drug quality control is essential in modern pharmaceutical analysis. This study presents, to the best of our knowledge, two independent and complementary analytical strategies for the simultaneous quantification of tiotropium bromide (TBM) and olodaterol hydrochloride (OLH) in laboratory-prepared mixtures and the pharmaceutical formulation Stiolto ® Respimat. The first strategy employed UV–Vis spectroscopy combined with Partial Least Squares (PLS), Genetic Algorithm-PLS (GA-PLS), and Multivariate Curve Resolution–Alternating Least Squares (MCR-ALS), whereas the second employed first-derivative Fourier Transform Infrared (FTIR) spectroscopy using zero-crossing wavenumbers. Validation mixtures were designed using Latin Hypercube Sampling to provide systematic coverage of the investigated concentration space. First-derivative preprocessing was applied to enhance spectral resolution and minimize baseline effects. The UV–Vis spectra in the range of 222–263 nm and FTIR spectra in the range of 4000–400 cm⁻¹ were used for quantitative analysis. Among the investigated UV–Vis chemometric models, MCR-ALS provided the lowest root mean square errors of calibration and prediction, with RMSEC and RMSEP values of 0.0359 and 0.0329 for TBM and 0.0622 and 0.0375 for OLH, respectively. The developed models provided recoveries of approximately 100%, with precision expressed as RSD values below 2%. Application to the commercial formulation produced satisfactory recoveries ranging from 98% to 101% for both drugs using the developed techniques. Statistical comparison with the reference HPLC method showed no significant differences at the 95% confidence level. Overall, the complementary UV–Vis chemometric and ATR-FTIR approaches provided satisfactory quantitative performance for the simultaneous determination of TBM and OLH within the investigated analytical ranges.
- 6 November 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 37203
Open AccessComplementary spectroscopic methods for simultaneous quantification of tiotropium bromide and olodaterol hydrochloride with analytical performance and environmental sustainability assessment
The development of efficient, cost-effective, and environmentally friendly analytical methods for drug quality control is essential in modern pharmaceutical analysis. This study presents, to the best of our knowledge, two independent and complementary analytical strategies for the simultaneous quantification of tiotropium bromide (TBM) and olodaterol hydrochloride (OLH) in laboratory-prepared mixtures and the pharmaceutical formulation Stiolto ® Respimat. The first strategy employed UV–Vis spectroscopy combined with Partial Least Squares (PLS), Genetic Algorithm-PLS (GA-PLS), and Multivariate Curve Resolution–Alternating Least Squares (MCR-ALS), whereas the second employed first-derivative Fourier Transform Infrared (FTIR) spectroscopy using zero-crossing wavenumbers. Validation mixtures were designed using Latin Hypercube Sampling to provide systematic coverage of the investigated concentration space. First-derivative preprocessing was applied to enhance spectral resolution and minimize baseline effects. The UV–Vis spectra in the range of 222–263 nm and FTIR spectra in the range of 4000–400 cm⁻¹ were used for quantitative analysis. Among the investigated UV–Vis chemometric models, MCR-ALS provided the lowest root mean square errors of calibration and prediction, with RMSEC and RMSEP values of 0.0359 and 0.0329 for TBM and 0.0622 and 0.0375 for OLH, respectively. The developed models provided recoveries of approximately 100%, with precision expressed as RSD values below 2%. Application to the commercial formulation produced satisfactory recoveries ranging from 98% to 101% for both drugs using the developed techniques. Statistical comparison with the reference HPLC method showed no significant differences at the 95% confidence level. Overall, the complementary UV–Vis chemometric and ATR-FTIR approaches provided satisfactory quantitative performance for the simultaneous determination of TBM and OLH within the investigated analytical ranges.
- Top Cited PapersOpen Access
- 23 June 2026
- Published by Elsevier in SLAS Technology
- Vol. 40, 100448
Smartphone-based colorimetric glucose biosensor using peroxidase-like activity of bimetallic catalyst supported onto graphitic carbon nitride nanosheets
- 23 June 2026
- Published by Elsevier in SLAS Technology
- Vol. 40, 100448
Top Cited PapersOpen AccessSmartphone-based colorimetric glucose biosensor using peroxidase-like activity of bimetallic catalyst supported onto graphitic carbon nitride nanosheets
- Open Access
- 18 June 2026
- Published by Elsevier in Talanta Open
- Vol. 14
Gold nanoparticles-decorated graphitic carbon nitride nanosheets for sensitive voltammetric determination of tadalafil in biological matrices
- 18 June 2026
- Published by Elsevier in Talanta Open
- Vol. 14
Open AccessGold nanoparticles-decorated graphitic carbon nitride nanosheets for sensitive voltammetric determination of tadalafil in biological matrices
- Open Access
- 26 December 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 418 (4) , 1259-1275
Dual-mode sensing strategy for assaying phosphate ions using Fe, N-co-doped carbon dots with peroxidase mimetic activity
Monitoring phosphate (PF) levels is critically significant because of its environmental, biomedical, and agricultural importance. In the current study, a novel dual-mode sensing platform was developed based on iron-doped nitrogen-rich carbon quantum dots (Fe@N-dCQDs), which exhibit both strong photoluminescence and intrinsic peroxidase mimetic activity. This dual property was the basis of PF determination, where its presence induced a concentration-dependent decrease in both colorimetric absorbance and fluorescence intensity, allowing for label-free and sensitive detection. The Fe@N-dCQDs were prepared using one-step pyrolysis and characterized by scanning electron microscope (SEM), transmission electron microscope (TEM), energy-dispersive X-ray spectroscopy (EDX), and Fourier transform infrared (FT-IR). The developed sensor showed excellent linearity in both detection modes (0.33–23.67 mM for the colorimetric method and 5.0–50.0 mM for the fluorometric method) with low detection limits (0.13 mM and 1.72 mM) and high correlation coefficients (0.9947 and 0.9998). Moreover, the sensor exhibited remarkable selectivity against common interfering ions typically found in environmental matrices, including phosphatic fertilizers. This simple, rapid, and cost-effective sensing strategy provides a promising tool for PF determination in environmental and agricultural samples and establishes Fe@N-dCQDs as a versatile nanomaterial for dual-mode analytical applications. Graphical Abstract
- 26 December 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 418 (4) , 1259-1275
Open AccessDual-mode sensing strategy for assaying phosphate ions using Fe, N-co-doped carbon dots with peroxidase mimetic activity
Monitoring phosphate (PF) levels is critically significant because of its environmental, biomedical, and agricultural importance. In the current study, a novel dual-mode sensing platform was developed based on iron-doped nitrogen-rich carbon quantum dots (Fe@N-dCQDs), which exhibit both strong photoluminescence and intrinsic peroxidase mimetic activity. This dual property was the basis of PF determination, where its presence induced a concentration-dependent decrease in both colorimetric absorbance and fluorescence intensity, allowing for label-free and sensitive detection. The Fe@N-dCQDs were prepared using one-step pyrolysis and characterized by scanning electron microscope (SEM), transmission electron microscope (TEM), energy-dispersive X-ray spectroscopy (EDX), and Fourier transform infrared (FT-IR). The developed sensor showed excellent linearity in both detection modes (0.33–23.67 mM for the colorimetric method and 5.0–50.0 mM for the fluorometric method) with low detection limits (0.13 mM and 1.72 mM) and high correlation coefficients (0.9947 and 0.9998). Moreover, the sensor exhibited remarkable selectivity against common interfering ions typically found in environmental matrices, including phosphatic fertilizers. This simple, rapid, and cost-effective sensing strategy provides a promising tool for PF determination in environmental and agricultural samples and establishes Fe@N-dCQDs as a versatile nanomaterial for dual-mode analytical applications. Graphical Abstract
- Open Access
- 24 December 2025
- Published by Springer Nature in BMC Chemistry
- Vol. 20 (1)
Hybrid sampling chemometric strategy for accurate and sustainable quantification of co-administered β-lactam antibiotics
Background: Reliable chemometric models require representative and well-distributed calibration and validation datasets. Objective: The current study introduces a novel framework integrating diverse sampling strategies with multivariate modeling for the simultaneous UV–Vis quantification of aztreonam (AZM) and meropenem (MPM). Methods: Three sampling techniques, including Monte Carlo (MC), Latin Hypercube Sampling (LHS), and Sobol Sequences (SS), were systematically evaluated in combination with Partial Least Squares (PLS), Genetic Algorithm–Assisted PLS (GA-PLS), and Artificial Neural Networks (ANN). Response surface strategy was followed for each sampling technique to assess their space coverage and points’ distribution across the experimental domain. Moreover, a hybrid variable-selection approach, namely, Genetic Algorithm Information Complexity–Partial Least Squares (GA-ICOMP-PLS), was also introduced to optimize PLS model variables. Different validation techniques, including nested cross-validation, Y-randomization tests, and noise-profiling, have been followed to ensure the models’ reliability. Results: The ANN model trained with the SS technique achieved the highest predictive accuracy, reducing RMSE by 2.6% for AZM and 39.9% for MPM compared to standard PLS. However, LHS-GA-PLS delivered low prediction errors (22.8% AZM and 5.7% MPM), while MC-PLS showed lower consistency due to non-uniform sampling. GA-ICOMP-PLS further improved prediction performance for both analytes, with error reduction ranging from 35.1% to 63.6% compared to conventional PLS. Rigorous validation testing confirmed unbiased predictions and model resilience under realistic analytical conditions. Significance: This is the first study to integrate structured sampling with chemometric modeling for β-lactam analysis. The approach improved model robustness, generalization, and sustainability, achieving high green metrics of SDS (Safety Data Sheets), AGREE (Analytical Greenness metric), and BAGI (Balanced Analytical Greenness Index) values of 0.84 and 85.0, respectively. The developed method represents a reliable, efficient, and eco-friendly strategy for pharmaceutical quality control and environmental monitoring. Graphical
- 24 December 2025
- Published by Springer Nature in BMC Chemistry
- Vol. 20 (1)
Open AccessHybrid sampling chemometric strategy for accurate and sustainable quantification of co-administered β-lactam antibiotics
Background: Reliable chemometric models require representative and well-distributed calibration and validation datasets. Objective: The current study introduces a novel framework integrating diverse sampling strategies with multivariate modeling for the simultaneous UV–Vis quantification of aztreonam (AZM) and meropenem (MPM). Methods: Three sampling techniques, including Monte Carlo (MC), Latin Hypercube Sampling (LHS), and Sobol Sequences (SS), were systematically evaluated in combination with Partial Least Squares (PLS), Genetic Algorithm–Assisted PLS (GA-PLS), and Artificial Neural Networks (ANN). Response surface strategy was followed for each sampling technique to assess their space coverage and points’ distribution across the experimental domain. Moreover, a hybrid variable-selection approach, namely, Genetic Algorithm Information Complexity–Partial Least Squares (GA-ICOMP-PLS), was also introduced to optimize PLS model variables. Different validation techniques, including nested cross-validation, Y-randomization tests, and noise-profiling, have been followed to ensure the models’ reliability. Results: The ANN model trained with the SS technique achieved the highest predictive accuracy, reducing RMSE by 2.6% for AZM and 39.9% for MPM compared to standard PLS. However, LHS-GA-PLS delivered low prediction errors (22.8% AZM and 5.7% MPM), while MC-PLS showed lower consistency due to non-uniform sampling. GA-ICOMP-PLS further improved prediction performance for both analytes, with error reduction ranging from 35.1% to 63.6% compared to conventional PLS. Rigorous validation testing confirmed unbiased predictions and model resilience under realistic analytical conditions. Significance: This is the first study to integrate structured sampling with chemometric modeling for β-lactam analysis. The approach improved model robustness, generalization, and sustainability, achieving high green metrics of SDS (Safety Data Sheets), AGREE (Analytical Greenness metric), and BAGI (Balanced Analytical Greenness Index) values of 0.84 and 85.0, respectively. The developed method represents a reliable, efficient, and eco-friendly strategy for pharmaceutical quality control and environmental monitoring. Graphical
- Open Access
- 10 July 2025
- Published by Springer Nature in BMC Chemistry
- Vol. 19 (1) , 1-24
Sustainable analysis of COVID-19 Co-packaged paxlovid: exploring advanced sampling techniques and multivariate processing tools
The drawbacks of random sampling not only hinder the development of more reliable and efficient methods but also weaken their accuracy, predictive abilities, and validity across several domains. During the current study, a pioneering statistical technique namely, Latin Hypercube Sampling (LHS) was integrated with different multivariate chemometric models namely; Partial Least Squares (PLS), Genetic Algorithm‑Partial Least Squares (GA-PLS), Artificial Neural Networks (ANN), and Multivariate Curve Resolution‑Alternating Least Squares (MCR-ALS). This integration aimed to achieve full data coverage and thereby enhance the predictive powers of these models. Being of clinical significance, Paxlovid®, a newly co-packaged antiCOVID-19 drug containing ritonavir (RNV)-boosted nirmatrelvir (NMV), was utilized as a study subject to demonstrate the powerful potentials of LHS in enhancing models’ robustness and predictive accuracy. The LHS technique was able to provide well-interpreted and informative samples by capturing essential variabilities across the input space without any increase in sample numbers. It was compared and outperformed the random sampling Monte Carlo technique. A comprehensive comparison between the developed models was held where the RMSEP was relatively reduced by 14.1%, 8.9%, 53.1%, and 34.6% for RNV and NMV, respectively using the ANN and MCR-ALS models. Various preprocessing techniques were employed to improve signal quality for PLS construction, yielding superior results (RMSEC of 0.19 for both RNV and NMV) compared to the original, unprocessed spectral data (RMSEC of 0.21 for both RNV and NMV). The Principal Component Analysis score plot was constructed, confirming the consistency of the dataset and the absence of systematic errors, enhancing confidence in the models’ robustness. A new hybrid variable selection strategy (GA-ICOMP-PLS) was developed to enhance the robustness and parsimony of the GA-PLS model. Prediction error values of 0.15 and 0.14 were successfully achieved for RNV and NMV, respectively, indicating strong predictive power and generalization. Consistent with sustainability and eco-friendly goals, the current study pioneers the usage of green–blue-white alternatives to conventional analytical methods. A comprehensive assessment was conducted using the “Sample Preparation Metric of Sustainability”, the “Analytical Greenness metric for Sample Preparation” and the “Analytical Greenness metric” alongside two solvent sustainability evaluation tools. These evaluations yielded promising results, with green quadrant classification and high scores of 5.89, 0.67, and 0.82 for each metric, respectively, as well as satisfactory t- and F-test values. Moreover, the models achieved outstanding results on the RGB12 metric and Blueness Applicability Grade Index, scoring 96.8% and 82.5, respectively, highlighting their broad applicability, high efficiency, and alignment with eco-friendly analytical practices.
- 10 July 2025
- Published by Springer Nature in BMC Chemistry
- Vol. 19 (1) , 1-24
Open AccessSustainable analysis of COVID-19 Co-packaged paxlovid: exploring advanced sampling techniques and multivariate processing tools
The drawbacks of random sampling not only hinder the development of more reliable and efficient methods but also weaken their accuracy, predictive abilities, and validity across several domains. During the current study, a pioneering statistical technique namely, Latin Hypercube Sampling (LHS) was integrated with different multivariate chemometric models namely; Partial Least Squares (PLS), Genetic Algorithm‑Partial Least Squares (GA-PLS), Artificial Neural Networks (ANN), and Multivariate Curve Resolution‑Alternating Least Squares (MCR-ALS). This integration aimed to achieve full data coverage and thereby enhance the predictive powers of these models. Being of clinical significance, Paxlovid®, a newly co-packaged antiCOVID-19 drug containing ritonavir (RNV)-boosted nirmatrelvir (NMV), was utilized as a study subject to demonstrate the powerful potentials of LHS in enhancing models’ robustness and predictive accuracy. The LHS technique was able to provide well-interpreted and informative samples by capturing essential variabilities across the input space without any increase in sample numbers. It was compared and outperformed the random sampling Monte Carlo technique. A comprehensive comparison between the developed models was held where the RMSEP was relatively reduced by 14.1%, 8.9%, 53.1%, and 34.6% for RNV and NMV, respectively using the ANN and MCR-ALS models. Various preprocessing techniques were employed to improve signal quality for PLS construction, yielding superior results (RMSEC of 0.19 for both RNV and NMV) compared to the original, unprocessed spectral data (RMSEC of 0.21 for both RNV and NMV). The Principal Component Analysis score plot was constructed, confirming the consistency of the dataset and the absence of systematic errors, enhancing confidence in the models’ robustness. A new hybrid variable selection strategy (GA-ICOMP-PLS) was developed to enhance the robustness and parsimony of the GA-PLS model. Prediction error values of 0.15 and 0.14 were successfully achieved for RNV and NMV, respectively, indicating strong predictive power and generalization. Consistent with sustainability and eco-friendly goals, the current study pioneers the usage of green–blue-white alternatives to conventional analytical methods. A comprehensive assessment was conducted using the “Sample Preparation Metric of Sustainability”, the “Analytical Greenness metric for Sample Preparation” and the “Analytical Greenness metric” alongside two solvent sustainability evaluation tools. These evaluations yielded promising results, with green quadrant classification and high scores of 5.89, 0.67, and 0.82 for each metric, respectively, as well as satisfactory t- and F-test values. Moreover, the models achieved outstanding results on the RGB12 metric and Blueness Applicability Grade Index, scoring 96.8% and 82.5, respectively, highlighting their broad applicability, high efficiency, and alignment with eco-friendly analytical practices.
- 3 October 2024
- Published by Elsevier in Sustainable Chemistry and Pharmacy
- Vol. 42
Sustainable chemometric analysis of tension headache drugs in the presence of nephrotoxic impurities
- 3 October 2024
- Published by Elsevier in Sustainable Chemistry and Pharmacy
- Vol. 42
Sustainable chemometric analysis of tension headache drugs in the presence of nephrotoxic impurities
- 1 October 2018
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 203, 112-117
Simultaneous spectrophotometric determination of compounds having relatively disparate absorbance and concentration ranges; application to antidiabetic formulation of linagliptin and metformin
- 1 October 2018
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 203, 112-117
Simultaneous spectrophotometric determination of compounds having relatively disparate absorbance and concentration ranges; application to antidiabetic formulation of linagliptin and metformin