Khusnul Khotimah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Khusnul Khotimah has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Vera Permatasari
Research Center for Pharmaceutical Ingredients and Traditional Medicine, National Research and Innovation Agency (BRIN), Kawasan Sains dan Teknologi (KST), BJ Habibie (PUSPIPTEK) Serpong, South Tangerang, Banten, Indonesia
2 shared publications Akihide Sugawara
1 shared publicationAli Nur Fathoni
Department of Electrical Engineering and Informatics, Universitas Gadjah Mada, Indonesia
1 shared publication- Asep Rahmat Hidayat
National Research and Innovation Agency Republic of Indonesia
1 shared publication - Elvina Trivida
National Research and Innovation Agency
1 shared publication H Aditya Chandra
Department of Electrical Engineering Education, Universitas Negeri Surabaya, Surabaya, Indonesia
1 shared publication
Latest Publications
- Open Access
- 1 February 2023
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 13 (1) , 1152-1160
Real-time wireless temperature measurement system of infant incubator
The internet of things (IoT) has allowed for ubiquitous measurement. Infant incubator temperature is one of crucial parts that need to be measured, especially for the stability and uniformity temperature. Based on the interpretation of IEC 60601-2-19, we proposed measurement method using IoT with the message queue telemetry transport (MQTT). In the 10,000 packet, the result shows the quality of service (QoS) level 2 of the system has the highest delay, however it has the lowest packet loss data than the other QoS. For 1 hour, the uniformity result and stability can fulfill the standards. Uniformity of 32°C, the lowest difference is point C with 0.32 °C, and the highest difference is point B with 0.75 °C. Uniformity of 36 °C, the lowest difference is point B with 0.27 °C, and the highest difference is point C with 0.79 °C. The stability of 32 °C and 36 °C is 0.32 °C and 0.44 °C, respectively. Moreover, the Kruskal Wallis test shows the highest difference average from point M is point A and B. It occurred because of the point A and B located far from the heater part, so the point A and B colder than point C.
- 1 February 2023
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 13 (1) , 1152-1160
Open AccessReal-time wireless temperature measurement system of infant incubator
The internet of things (IoT) has allowed for ubiquitous measurement. Infant incubator temperature is one of crucial parts that need to be measured, especially for the stability and uniformity temperature. Based on the interpretation of IEC 60601-2-19, we proposed measurement method using IoT with the message queue telemetry transport (MQTT). In the 10,000 packet, the result shows the quality of service (QoS) level 2 of the system has the highest delay, however it has the lowest packet loss data than the other QoS. For 1 hour, the uniformity result and stability can fulfill the standards. Uniformity of 32°C, the lowest difference is point C with 0.32 °C, and the highest difference is point B with 0.75 °C. Uniformity of 36 °C, the lowest difference is point B with 0.27 °C, and the highest difference is point C with 0.79 °C. The stability of 32 °C and 36 °C is 0.32 °C and 0.44 °C, respectively. Moreover, the Kruskal Wallis test shows the highest difference average from point M is point A and B. It occurred because of the point A and B located far from the heater part, so the point A and B colder than point C.
- Open Access
- 1 December 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 12 (6) , 5900-5910
Conducted emission investigation of infant incubator heating control mode
This paper investigates the effect of two different heating power control systems of infant incubators on their conducted emissions. Two infant incubators which respectively employ zero-crossing control mode and phase angle control mode are observed. The research was conducted by measuring conducted electromagnetic interference (EMI) from each infant incubator's power input. Measurements are conducted both during full power condition, while the incubator's compartment temperature is far away from the temperature setpoint, and during power chopping condition, while the compartment temperature reaches the steady-state set point. Method and limit of the measurement refer to CISPR 11. It is found that conducted emission higher than the standard CISPR 11 limit occurs during power chopping on phase angle control mode. This results from the sharp rise time of voltage delivered to the heater, around 220 ns for each chopping cycle.
- 1 December 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 12 (6) , 5900-5910
Open AccessConducted emission investigation of infant incubator heating control mode
This paper investigates the effect of two different heating power control systems of infant incubators on their conducted emissions. Two infant incubators which respectively employ zero-crossing control mode and phase angle control mode are observed. The research was conducted by measuring conducted electromagnetic interference (EMI) from each infant incubator's power input. Measurements are conducted both during full power condition, while the incubator's compartment temperature is far away from the temperature setpoint, and during power chopping condition, while the compartment temperature reaches the steady-state set point. Method and limit of the measurement refer to CISPR 11. It is found that conducted emission higher than the standard CISPR 11 limit occurs during power chopping on phase angle control mode. This results from the sharp rise time of voltage delivered to the heater, around 220 ns for each chopping cycle.
- Open Access
- 24 November 2020
- Published by Atlantis Press SARL
- p. 136-140
Design Automatic Hand Sanitizer Microcontroller Based using Arduino Nano and Ultrasonic Sensors as an Effort to Prevent the Spread of Covid-19
- 24 November 2020
- Published by Atlantis Press SARL
- p. 136-140
Open AccessDesign Automatic Hand Sanitizer Microcontroller Based using Arduino Nano and Ultrasonic Sensors as an Effort to Prevent the Spread of Covid-19