Gemma Taverni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gemma Taverni has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Chenghan Li
Institute of Neuroinformatics University of Zürich and ETH Zürich Zürich8057, Switzerland
1 shared publication - Diederik Paul Moeys
Institute of Neuroinformatics University of Zürich and ETH Zürich Zürich8057, Switzerland
1 shared publication - Fabian F. Voigt
Brain Research Institute, University of Zurich, Winterthurerstrasse 190, 8057 Zurich, Switzerland
1 shared publication - Federico Corradi
Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
1 shared publication - Fritjof Helmchen
Brain Research Institute, University of Zürich, Zürich, Switzerland
1 shared publication - Luca Longinotti
Inilabs Ltd., 8001 Zürich, Switzerland
1 shared publication
Latest Publications
- Top Cited PapersOpen Access
- 3 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (1) , 123-136
A Sensitive Dynamic and Active Pixel Vision Sensor for Color or Neural Imaging Applications
Applications requiring detection of small visual contrast require high sensitivity. Event cameras can provide higher dynamic range (DR) and reduce data rate and latency, but most existing event cameras have limited sensitivity. This paper presents the results of a 180-nm Towerjazz CIS process vision sensor called SDAVIS192. It outputs temporal contrast dynamic vision sensor (DVS) events and conventional active pixel sensor frames. The SDAVIS192 improves on previous DAVIS sensors with higher sensitivity for temporal contrast. The temporal contrast thresholds can be set down to 1% for negative changes in logarithmic intensity (OFF events) and down to 3.5% for positive changes (ON events). The achievement is possible through the adoption of an in-pixel preamplification stage. This preamplifier reduces the effective intrascene DR of the sensor (70 dB for OFF and 50 dB for ON), but an automated operating region control allows up to at least 110-dB DR for OFF events. A second contribution of this paper is the development of characterization methodology for measuring DVS event detection thresholds by incorporating a measure of signal-to-noise ratio (SNR). At average SNR of 30 dB, the DVS temporal contrast threshold fixed pattern noise is measured to be 0.3%–0.8% temporal contrast. Results comparing monochrome and RGBW color filter array DVS events are presented. The higher sensitivity of SDAVIS192 make this sensor potentially useful for calcium imaging, as shown in a recording from cultured neurons expressing calcium sensitive green fluorescent protein GCaMP6f.
- 3 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (1) , 123-136
Top Cited PapersOpen AccessA Sensitive Dynamic and Active Pixel Vision Sensor for Color or Neural Imaging Applications
Applications requiring detection of small visual contrast require high sensitivity. Event cameras can provide higher dynamic range (DR) and reduce data rate and latency, but most existing event cameras have limited sensitivity. This paper presents the results of a 180-nm Towerjazz CIS process vision sensor called SDAVIS192. It outputs temporal contrast dynamic vision sensor (DVS) events and conventional active pixel sensor frames. The SDAVIS192 improves on previous DAVIS sensors with higher sensitivity for temporal contrast. The temporal contrast thresholds can be set down to 1% for negative changes in logarithmic intensity (OFF events) and down to 3.5% for positive changes (ON events). The achievement is possible through the adoption of an in-pixel preamplification stage. This preamplifier reduces the effective intrascene DR of the sensor (70 dB for OFF and 50 dB for ON), but an automated operating region control allows up to at least 110-dB DR for OFF events. A second contribution of this paper is the development of characterization methodology for measuring DVS event detection thresholds by incorporating a measure of signal-to-noise ratio (SNR). At average SNR of 30 dB, the DVS temporal contrast threshold fixed pattern noise is measured to be 0.3%–0.8% temporal contrast. Results comparing monochrome and RGBW color filter array DVS events are presented. The higher sensitivity of SDAVIS192 make this sensor potentially useful for calcium imaging, as shown in a recording from cultured neurons expressing calcium sensitive green fluorescent protein GCaMP6f.