Abdulsalam Arif Aloukili
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Abdulsalam Arif Aloukili has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed O. Badr
Electrical Power and Machines Department, Faculty of Engineering, Ain Shams University, Cairo 11517, Egypt
2 shared publications - Mahmoud Abdallah Attia
Ain Shams University
2 shared publications - Mariam A. Sameh
Energy Engineering Department, Elsewedy University of Technology, Polytechnic Egypt, Postal Code: 11835, Cairo, Egypt
2 shared publications - Metwally A. El-Sharkawy
Department of Electrical Power and Machines, Faculty of Engineering, Ain Shams University, Cairo 11517, Egypt
2 shared publications - Mohammed Ahmed Mehanna
Department of Electrical Engineering, Al-Azhar University, Egypt
1 shared publication Mohammed Mehanna
Electrical Engineering Department, Faculty of Engineering, Al-Azhar University, Cairo, Egypt
1 shared publication
Latest Publications
- 10 November 2026
- Published by Libyan Society for Research and Scientific Studies in International Science and Technology Journal
Tie-Line Power Flow Strategies for Enhanced Load Frequency Control in Multi-Area Power Systems
This study presents a detailed investigation aimed at enhancing load frequency control (LFC) within a three-area non-reheat power system through the integration of energy storage devices. The primary objective is to evaluate the impact of minimizing power flow across tie lines between areas versus allowing it to fluctuate freely based on demand. This comparison seeks to determine the effects on LFC parameters under both scenarios. Additionally, the research examines the potential benefits of incorporating or excluding power tie lines in the objective function to achieve superior LFC performance. To conduct this analysis, two controller designs were employed: a Proportional-Integral-Derivative Filter (PIDF) optimized using the Mountain Gazelle Optimizer (MGO) and a hybrid controller that merges fuzzy logic with MGO (Fuzzy PI-PIDF). The performance of the LFC system was assessed using the Integral Time-Absolute Error (ITAE) as the objective function, which considers area control error, including frequency deviations and power tie-line interactions. The ITAE was also utilized to evaluate frequency deviations independently, excluding power tie lines from the objective function. Simulation results demonstrate the effectiveness of the proposed controllers in improving LFC system performance. Notably, the PIDF controller, tuned by MGO and based on ITAE that focuses solely on frequency deviation, significantly outperformed the other controllers, achieving substantial reductions in overshoot, undershoot, and settling time. Keywords: load frequency control, Mountain Gazelle Optimizer, Integral Time-Absolute Error, power tie line.
- 10 November 2026
- Published by Libyan Society for Research and Scientific Studies in International Science and Technology Journal
Tie-Line Power Flow Strategies for Enhanced Load Frequency Control in Multi-Area Power Systems
This study presents a detailed investigation aimed at enhancing load frequency control (LFC) within a three-area non-reheat power system through the integration of energy storage devices. The primary objective is to evaluate the impact of minimizing power flow across tie lines between areas versus allowing it to fluctuate freely based on demand. This comparison seeks to determine the effects on LFC parameters under both scenarios. Additionally, the research examines the potential benefits of incorporating or excluding power tie lines in the objective function to achieve superior LFC performance. To conduct this analysis, two controller designs were employed: a Proportional-Integral-Derivative Filter (PIDF) optimized using the Mountain Gazelle Optimizer (MGO) and a hybrid controller that merges fuzzy logic with MGO (Fuzzy PI-PIDF). The performance of the LFC system was assessed using the Integral Time-Absolute Error (ITAE) as the objective function, which considers area control error, including frequency deviations and power tie-line interactions. The ITAE was also utilized to evaluate frequency deviations independently, excluding power tie lines from the objective function. Simulation results demonstrate the effectiveness of the proposed controllers in improving LFC system performance. Notably, the PIDF controller, tuned by MGO and based on ITAE that focuses solely on frequency deviation, significantly outperformed the other controllers, achieving substantial reductions in overshoot, undershoot, and settling time. Keywords: load frequency control, Mountain Gazelle Optimizer, Integral Time-Absolute Error, power tie line.
- Open Access
- 29 July 2024
- Published by Egyptian Knowledge Bank in Journal of Al-Azhar University Engineering Sector
- Vol. 19 (72) , 234-249
LOAD FREQUENCY CONTROL OPTIMIZATION USING MGO-BASED PIDF IN THREE-AREA SYSTEMS WITH ENERGY STORAGE
Maintaining the stability and reliability of power systems is a key function of load frequency control (LFC). However, issues such as load variations, network challenges, and introducing renewable energy sources complicate this task. Consequently, devising an efficient controller for LFC becomes a complex optimization issue. In this paper, we propose a distinctive controller for LFC built on a proportional-integral-derivative (PID) controller and a derivative filter (PIDF). To find the optimum parameters of PIDF controllers, use Mountain Gazelle Optimizer (MGO), an algorithm that draws inspiration from the behavior of mountain gazelles. The performance of this controller is contrasted with that of another PIDF controller that leverages the Harmony Search (HS) algorithm. The controllers are evaluated using a three-area non-reheat thermal system, both with and without storage systems like superconducting magnetic energy storage (SMES) and battery energy storage (BES). The Integral Time Absolute Error (ITAE) serves as the objective function for the assessment of these controllers. The MGO-based PIDF controller with Energy Storage (ES) works better than the HS-based PIDF controller with and without ES, as well as the MGO-based PIDF controller without ES, when ITAE, frequency deviation, and tie-line power deviation are taken into account. Furthermore, the MGO-based PIDF controller exhibits superior robustness and noise immunity compared to the others. In conclusion, the controller proposed in this paper presents a potential solution for LFC in contemporary power systems. Special Issue of AEIC 2024 (Electrical and System & Computer Engineering Session)
- 29 July 2024
- Published by Egyptian Knowledge Bank in Journal of Al-Azhar University Engineering Sector
- Vol. 19 (72) , 234-249
Open AccessLOAD FREQUENCY CONTROL OPTIMIZATION USING MGO-BASED PIDF IN THREE-AREA SYSTEMS WITH ENERGY STORAGE
Maintaining the stability and reliability of power systems is a key function of load frequency control (LFC). However, issues such as load variations, network challenges, and introducing renewable energy sources complicate this task. Consequently, devising an efficient controller for LFC becomes a complex optimization issue. In this paper, we propose a distinctive controller for LFC built on a proportional-integral-derivative (PID) controller and a derivative filter (PIDF). To find the optimum parameters of PIDF controllers, use Mountain Gazelle Optimizer (MGO), an algorithm that draws inspiration from the behavior of mountain gazelles. The performance of this controller is contrasted with that of another PIDF controller that leverages the Harmony Search (HS) algorithm. The controllers are evaluated using a three-area non-reheat thermal system, both with and without storage systems like superconducting magnetic energy storage (SMES) and battery energy storage (BES). The Integral Time Absolute Error (ITAE) serves as the objective function for the assessment of these controllers. The MGO-based PIDF controller with Energy Storage (ES) works better than the HS-based PIDF controller with and without ES, as well as the MGO-based PIDF controller without ES, when ITAE, frequency deviation, and tie-line power deviation are taken into account. Furthermore, the MGO-based PIDF controller exhibits superior robustness and noise immunity compared to the others. In conclusion, the controller proposed in this paper presents a potential solution for LFC in contemporary power systems. Special Issue of AEIC 2024 (Electrical and System & Computer Engineering Session)
- Open Access
- 1 January 2023
- Published by International Journal of Renewable Energy Research in International Journal of Renewable Energy Research
- Vol. 13 (V13i4) , 1632-1645
Improved of Load Frequency Control in a Three-Area Non-Reheat System Using Hybrid Fuzzy-PI Controller and PIDF based on Mountain Gazelle Optimizer
Abstract- This research suggest a new load frequency control (LFC) system for a three-area non-reheat system. The system that is suggested employs a hybrid fuzzy-PI controller and Mountain Gazelle Optimizer (MGO), with Integral Time Absolute Error ITAE serving as the objective function. The proposed controller's performance is compared with different techniques including PID based on MGO, PID-based on transet search optimizer TSO, PID-based on Pelican Optimization Algorithm POA, fuzzy-TSO, and fuzzy-POA. The proposed hybrid fuzzy-PI controller with MGO performs better than the other controllers in terms of reduced settling time, maximum overshoot, maximum undershoot of frequancy deveation, and ITAE, according to the results. The effectiveness of the proposed controller is further verified in various scenarios, including sudden changes in loads and the incorporation of renewable energy sources (RESs), such as wind turbines and solar panels, along with energy storage systems. Overall, the findings show that the suggested controller is a successful method for enhancing frequency stability in a three-area non-reheat power system under a variety of operating scenarios. Matlab 2020 was used in this work.
- 1 January 2023
- Published by International Journal of Renewable Energy Research in International Journal of Renewable Energy Research
- Vol. 13 (V13i4) , 1632-1645
Open AccessImproved of Load Frequency Control in a Three-Area Non-Reheat System Using Hybrid Fuzzy-PI Controller and PIDF based on Mountain Gazelle Optimizer
Abstract- This research suggest a new load frequency control (LFC) system for a three-area non-reheat system. The system that is suggested employs a hybrid fuzzy-PI controller and Mountain Gazelle Optimizer (MGO), with Integral Time Absolute Error ITAE serving as the objective function. The proposed controller's performance is compared with different techniques including PID based on MGO, PID-based on transet search optimizer TSO, PID-based on Pelican Optimization Algorithm POA, fuzzy-TSO, and fuzzy-POA. The proposed hybrid fuzzy-PI controller with MGO performs better than the other controllers in terms of reduced settling time, maximum overshoot, maximum undershoot of frequancy deveation, and ITAE, according to the results. The effectiveness of the proposed controller is further verified in various scenarios, including sudden changes in loads and the incorporation of renewable energy sources (RESs), such as wind turbines and solar panels, along with energy storage systems. Overall, the findings show that the suggested controller is a successful method for enhancing frequency stability in a three-area non-reheat power system under a variety of operating scenarios. Matlab 2020 was used in this work.
- Open Access
Optimal DGs Siting and Sizing Considering Hybrid Static and Dynamic Loads, and Overloading Conditions
There is no doubt that Distributed Generation (DG) has proved to be an effective solution for satisfying the growing demand within a fleeting period and improving system performance, voltage profile, and power quality, especially on the end user’s side. Thus, in modern distribution systems, DG is preferable to be installed in the vicinity of the end user to enhance the system performance, reduce power losses, and improve grid voltage. In this paper, hybrid static and dynamic load types (100% static, 50% static and 50% dynamic, and 100% dynamic loads) at different overloading conditions, for the standard IEEE 33-bus system, are considered, and power system performance is recorded. Moreover, to improve the power system performance, Distributed Generations (DGs) are optimally sized and allocated in the IEEE 33-bus system using the Harmony Search Algorithm (HSA), and two analytical approaches, respectively, and compared to other reported optimization methods. The results show that, at 100% loading, the minimum bus voltage for the proposed method reached 0.97 pu, compared to 0.94 pu for the Particle Swarm Optimization (PSO) algorithm and 0.9574 pu for the Improved Analytical (IA) method. From the results obtained in this paper, it can be concluded that the proposed technique improved the performance of the studied power system, compared to other reported techniques, by enhancing the voltage profile and minimizing the power losses.
Open AccessOptimal DGs Siting and Sizing Considering Hybrid Static and Dynamic Loads, and Overloading Conditions
There is no doubt that Distributed Generation (DG) has proved to be an effective solution for satisfying the growing demand within a fleeting period and improving system performance, voltage profile, and power quality, especially on the end user’s side. Thus, in modern distribution systems, DG is preferable to be installed in the vicinity of the end user to enhance the system performance, reduce power losses, and improve grid voltage. In this paper, hybrid static and dynamic load types (100% static, 50% static and 50% dynamic, and 100% dynamic loads) at different overloading conditions, for the standard IEEE 33-bus system, are considered, and power system performance is recorded. Moreover, to improve the power system performance, Distributed Generations (DGs) are optimally sized and allocated in the IEEE 33-bus system using the Harmony Search Algorithm (HSA), and two analytical approaches, respectively, and compared to other reported optimization methods. The results show that, at 100% loading, the minimum bus voltage for the proposed method reached 0.97 pu, compared to 0.94 pu for the Particle Swarm Optimization (PSO) algorithm and 0.9574 pu for the Improved Analytical (IA) method. From the results obtained in this paper, it can be concluded that the proposed technique improved the performance of the studied power system, compared to other reported techniques, by enhancing the voltage profile and minimizing the power losses.
- Open Access
- 1 December 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (23) , 16094
Compensation of Distributed Generations Outage Using Controlled Switched Capacitors
Researchers recently came up with innovative ways to generate enough electricity to meet the rising demand through establishing an electricity distribution system and enhancing power quality on the customer side. One of these innovative ways is the installation of distributed generation (DG). DG is widely used in modern networks due to its great benefits of improving the voltage profile and the system’s power quality. Additionally, DGs are ideally placed near the end user in distribution systems to improve the system’s performance while minimizing power losses and enhancing voltage profile in the grid. DG recently grew in importance, and its penetration increased in most distribution systems. Due to the spreading of DG in the power system, the dynamic performance of the system is affected. This paper studies the system’s performance and behavior under condition of DG outage from the system. The model of DGs in this study assumes two cases of the power provided to the network; the first case considered DG units injecting active power only to the grid (unity power factor). In the second case, DG injects both active and reactive power to the system. After that, outage of DG units is fixed by injecting a reactive power source using a capacitor with a controlled switch to compensate the outage of DGs from the distribution system and to reduce the outage’s negative effect on the network. The sizing of capacitors is optimized using a harmony search algorithm (HSA) in the same location of the DG units.
- 1 December 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (23) , 16094
Open AccessCompensation of Distributed Generations Outage Using Controlled Switched Capacitors
Researchers recently came up with innovative ways to generate enough electricity to meet the rising demand through establishing an electricity distribution system and enhancing power quality on the customer side. One of these innovative ways is the installation of distributed generation (DG). DG is widely used in modern networks due to its great benefits of improving the voltage profile and the system’s power quality. Additionally, DGs are ideally placed near the end user in distribution systems to improve the system’s performance while minimizing power losses and enhancing voltage profile in the grid. DG recently grew in importance, and its penetration increased in most distribution systems. Due to the spreading of DG in the power system, the dynamic performance of the system is affected. This paper studies the system’s performance and behavior under condition of DG outage from the system. The model of DGs in this study assumes two cases of the power provided to the network; the first case considered DG units injecting active power only to the grid (unity power factor). In the second case, DG injects both active and reactive power to the system. After that, outage of DG units is fixed by injecting a reactive power source using a capacitor with a controlled switch to compensate the outage of DGs from the distribution system and to reduce the outage’s negative effect on the network. The sizing of capacitors is optimized using a harmony search algorithm (HSA) in the same location of the DG units.