Xia Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xia Yu has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
Zhouzhuo Tang
8 shared publicationsJing Ni
7 shared publications- Qi Jie Wang
School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore, Singapore
6 shared publications Zihao Liu
6 shared publicationsShichao Yang
5 shared publicationsYingmei Feng
Capital Medical University
5 shared publications
Latest Publications
- 19 November 2026
- Published by Elsevier in Optics & Laser Technology
- Vol. 205
Advances in 3–14 µm mid-infrared pulsed laser sources
- 19 November 2026
- Published by Elsevier in Optics & Laser Technology
- Vol. 205
Advances in 3–14 µm mid-infrared pulsed laser sources
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Emerging Topics in Computational Intelligence
- Vol. 10 (4) , 2982-2997
On-Site Precise Diagnosis of COVID-19 Using an Attention-Based PLS-1D-CNN Model With Biomolecular Infrared Signatures
During the early stage of respiratory virus outbreaks, such as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the efficient utilize of limited nasopharyngeal swabs for rapid and accurate screening is crucial for public health. In this study, we present a methodology that integrates attenuated total reflection-Fourier transform infrared spectroscopy (ATR-FTIR) with the adaptive iteratively reweighted penalized least squares (airPLS) preprocessing algorithm and a channel-wise attention-based partial least squares one-dimensional convolutional neural network (PLS-1D-CNN) model, enabling accurate screening of infected individuals within 10 minutes. To evaluate the quality of spectral signals obtained under different experimental protocols, a biomolecular importance (BMI) evaluation method was introduced to quantify the contribution of virus related biomolecules during feature extraction. Two cohorts of nasopharyngeal swab samples, comprising 126 and 112 samples from suspected SARS-CoV-2 Omicron variant cases, were collected at Beijing Youan Hospital for verification. For the ATR-FTIR spectra in Cohort 2, which exhibited higher BMI values, the airPLS algorithm was applied for baseline correction, followed by classification using the channel-wise attention based PLS-1D-CNN model. The proposed diagnostic system achieved a screening sensitivity of 96.24% and a specificity of 97.14%, outperforming previously reported methods. To further examine the generalizability and robustness of the proposed approach, an additional dataset (Cohort 3) was collected and validated under varying experimental conditions. The system maintained a screening sensitivity of approximately 96.00%, and the consistent results across different settings confirm the effectiveness and reliability of the proposed diagnostic method.
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Emerging Topics in Computational Intelligence
- Vol. 10 (4) , 2982-2997
On-Site Precise Diagnosis of COVID-19 Using an Attention-Based PLS-1D-CNN Model With Biomolecular Infrared Signatures
During the early stage of respiratory virus outbreaks, such as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the efficient utilize of limited nasopharyngeal swabs for rapid and accurate screening is crucial for public health. In this study, we present a methodology that integrates attenuated total reflection-Fourier transform infrared spectroscopy (ATR-FTIR) with the adaptive iteratively reweighted penalized least squares (airPLS) preprocessing algorithm and a channel-wise attention-based partial least squares one-dimensional convolutional neural network (PLS-1D-CNN) model, enabling accurate screening of infected individuals within 10 minutes. To evaluate the quality of spectral signals obtained under different experimental protocols, a biomolecular importance (BMI) evaluation method was introduced to quantify the contribution of virus related biomolecules during feature extraction. Two cohorts of nasopharyngeal swab samples, comprising 126 and 112 samples from suspected SARS-CoV-2 Omicron variant cases, were collected at Beijing Youan Hospital for verification. For the ATR-FTIR spectra in Cohort 2, which exhibited higher BMI values, the airPLS algorithm was applied for baseline correction, followed by classification using the channel-wise attention based PLS-1D-CNN model. The proposed diagnostic system achieved a screening sensitivity of 96.24% and a specificity of 97.14%, outperforming previously reported methods. To further examine the generalizability and robustness of the proposed approach, an additional dataset (Cohort 3) was collected and validated under varying experimental conditions. The system maintained a screening sensitivity of approximately 96.00%, and the consistent results across different settings confirm the effectiveness and reliability of the proposed diagnostic method.
- 9 July 2026
- Published by Elsevier in Optics & Laser Technology
- Vol. 203
Plasma light source with enhanced ultraviolet brightness sustained by high-power orthogonal lasers
- 9 July 2026
- Published by Elsevier in Optics & Laser Technology
- Vol. 203
Plasma light source with enhanced ultraviolet brightness sustained by high-power orthogonal lasers
- 19 May 2026
- Published by Elsevier in Optics & Laser Technology
- Vol. 203
Stabilization of laser-sustained plasma light sources via near-anode plasma confinement in the gravitational field
- 19 May 2026
- Published by Elsevier in Optics & Laser Technology
- Vol. 203
Stabilization of laser-sustained plasma light sources via near-anode plasma confinement in the gravitational field
- 16 April 2026
- Published by Wiley in Laser & Photonics Reviews
- Vol. 20 (16) , e02913
High‐Purity Circularly Polarized Collimated Beam Generation via Metasurface‐Enabled Fiber Device
Generation of a circularly polarized collimated beam is crucial in various photonic systems, such as bio-imaging systems, on-chip integration systems, and quantum sensing platforms. Yet, conventional approaches relying on cascaded bulk optics (e.g., collimating lenses, waveplates, and polarizers) significantly increase system footprint and alignment complexity. Here, we present a compact metasurface-enabled fiber device that directly generates high-purity, low-divergence circularly polarized beams. The device employs a single-layer transmissive metasurface, with a glass-tube-based assembly method for connecting the metasurface to the fiber. Experimental characterization demonstrates a half-divergence angle below 0.02 , circular polarization purity exceeding 0.993 across the entire beam, and a transmission efficiency of 68% for the target polarization state. This work provides a compact, fiber-compatible solution for simultaneous beam collimation and polarization control, with immediate applications in atomic magnetometers, quantum sensing, and other space-constrained photonic systems.- 16 April 2026
- Published by Wiley in Laser & Photonics Reviews
- Vol. 20 (16) , e02913
High‐Purity Circularly Polarized Collimated Beam Generation via Metasurface‐Enabled Fiber Device
Generation of a circularly polarized collimated beam is crucial in various photonic systems, such as bio-imaging systems, on-chip integration systems, and quantum sensing platforms. Yet, conventional approaches relying on cascaded bulk optics (e.g., collimating lenses, waveplates, and polarizers) significantly increase system footprint and alignment complexity. Here, we present a compact metasurface-enabled fiber device that directly generates high-purity, low-divergence circularly polarized beams. The device employs a single-layer transmissive metasurface, with a glass-tube-based assembly method for connecting the metasurface to the fiber. Experimental characterization demonstrates a half-divergence angle below 0.02 , circular polarization purity exceeding 0.993 across the entire beam, and a transmission efficiency of 68% for the target polarization state. This work provides a compact, fiber-compatible solution for simultaneous beam collimation and polarization control, with immediate applications in atomic magnetometers, quantum sensing, and other space-constrained photonic systems.- Open Access
- 9 March 2026
- Published by Elsevier in SSRN Electronic Journal
Stabilization of laser-sustained plasma light sources via near-anode confinement in the gravitational field
The vertical arrangement of xenon lamps along the direction of gravity represents the most prevalent implementation of laser-sustained plasma (LSP) light sources, which features a longer working life. However, the vortices formed around the LSP plume tend to cause periodic energy exchange between the plasma and the surrounding filling gas. This periodic behavior will lead to fluctuations in the radiation flux in LSP light source applications. This paper reveals the mechanism by which the instability of LSP light sources is suppressed under a gravity direction setting through a combination of experimental observations, phase space dynamics analysis and numerical simulations. Specifically, shadowgraphy was employed to visualize the plume oscillation state at different electrode-plasma distances along the gravitational direction. It was found that the periodic plume oscillation gradually weakens as the plasma approaches the upper anode. The oscillation disappeared when the continuous decrease fell below a certain threshold. Subsequently, the phase space reconstruction of the LSP radiation intensity time series was performed, revealing phase space reconstruction curves for different plume states. The three-dimensional transient fluid model revealed the distributions of temperature, density, and velocity in oscillatory, critical, and steady states. Simulation calculations showed that under the guiding and stabilizing effect of the upper anode in proximity to the plasma, the velocity of the heated ascending gas flow is effectively suppressed, and the instability of the LSP light sources is eliminated. This work not only advances understanding of the internal fluid dynamics of LSP light sources but also provides a reference for the performance optimization of high-stability light sources in optical detection systems.
- 9 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessStabilization of laser-sustained plasma light sources via near-anode confinement in the gravitational field
The vertical arrangement of xenon lamps along the direction of gravity represents the most prevalent implementation of laser-sustained plasma (LSP) light sources, which features a longer working life. However, the vortices formed around the LSP plume tend to cause periodic energy exchange between the plasma and the surrounding filling gas. This periodic behavior will lead to fluctuations in the radiation flux in LSP light source applications. This paper reveals the mechanism by which the instability of LSP light sources is suppressed under a gravity direction setting through a combination of experimental observations, phase space dynamics analysis and numerical simulations. Specifically, shadowgraphy was employed to visualize the plume oscillation state at different electrode-plasma distances along the gravitational direction. It was found that the periodic plume oscillation gradually weakens as the plasma approaches the upper anode. The oscillation disappeared when the continuous decrease fell below a certain threshold. Subsequently, the phase space reconstruction of the LSP radiation intensity time series was performed, revealing phase space reconstruction curves for different plume states. The three-dimensional transient fluid model revealed the distributions of temperature, density, and velocity in oscillatory, critical, and steady states. Simulation calculations showed that under the guiding and stabilizing effect of the upper anode in proximity to the plasma, the velocity of the heated ascending gas flow is effectively suppressed, and the instability of the LSP light sources is eliminated. This work not only advances understanding of the internal fluid dynamics of LSP light sources but also provides a reference for the performance optimization of high-stability light sources in optical detection systems.
- 8 July 2025
- Published by Wiley in Laser & Photonics Reviews
- Vol. 19 (23)
Advanced Mid‐Infrared Laser Spectroscopy for Ultra‐Low Concentration Protein Detection
Mid‐infrared absorption spectroscopy stands as a pivotal technique for protein analysis, offering noninvasive, label‐free detection and the capability of real‐time monitoring, and can reflect conformational changes through spectral characteristics. Despite its significance, the prevailing mid‐infrared absorption spectroscopy systems for protein analysis are hampered by instrument complexity, high costs, and limited sensitivity, which impede their widespread application. Here, a high‐sensitivity protein mid‐infrared laser spectroscopy sensor using a quartz hollow waveguide as a microfluidic reaction vessel is proposed. On the ultra‐long reaction path provided by quartz hollow waveguides, gold core–shell nanoparticles are modified to induce surface‐enhanced infrared absorption (SEIRA) effect, and further biotin functionalization to obtain streptavidin capture capability. Notably, the gold core–shell particles are optimized based on the time‐coupled mode theory (TCMT) to better match the hollow waveguide transmission structure. The results demonstrate that the detection limits of streptavidin in the amide I and amide II bands are 35.68 and 38.69 ng mL −1 , respectively. The proposed surface enhanced hollow waveguide realizes the simultaneous detection of the lowest detection limit of the protein amide I and amide II bands by infrared spectroscopy, which provides a powerful platform for protein analysis.
- 8 July 2025
- Published by Wiley in Laser & Photonics Reviews
- Vol. 19 (23)
Advanced Mid‐Infrared Laser Spectroscopy for Ultra‐Low Concentration Protein Detection
Mid‐infrared absorption spectroscopy stands as a pivotal technique for protein analysis, offering noninvasive, label‐free detection and the capability of real‐time monitoring, and can reflect conformational changes through spectral characteristics. Despite its significance, the prevailing mid‐infrared absorption spectroscopy systems for protein analysis are hampered by instrument complexity, high costs, and limited sensitivity, which impede their widespread application. Here, a high‐sensitivity protein mid‐infrared laser spectroscopy sensor using a quartz hollow waveguide as a microfluidic reaction vessel is proposed. On the ultra‐long reaction path provided by quartz hollow waveguides, gold core–shell nanoparticles are modified to induce surface‐enhanced infrared absorption (SEIRA) effect, and further biotin functionalization to obtain streptavidin capture capability. Notably, the gold core–shell particles are optimized based on the time‐coupled mode theory (TCMT) to better match the hollow waveguide transmission structure. The results demonstrate that the detection limits of streptavidin in the amide I and amide II bands are 35.68 and 38.69 ng mL −1 , respectively. The proposed surface enhanced hollow waveguide realizes the simultaneous detection of the lowest detection limit of the protein amide I and amide II bands by infrared spectroscopy, which provides a powerful platform for protein analysis.