Sho Fujiyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sho Fujiyama has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Haruyuki Murakami
National Institutes for Quantum Science and Technology, Naka, Japan
1 shared publication - Hirotaka Meguro
Sophia University, 13070 Chiyoda-ku, Tokyo Japan
1 shared publication - Kaname Kizu
National Institutes for Quantum and Radiological Science and Technology
1 shared publication - Kazuya Nakamura
Faculty of Science and Technology, Sophia University, Tokyo, Japan
1 shared publication - Keisuke Nasu
Sophia University, 13070 Chiyoda-ku, Tokyo Japan
1 shared publication - Kyohei Natsume
National Institute for Materials Science, Tsukuba, Japan
1 shared publication
Latest Publications
- 4 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-5
Evaluation of Voltage Between Conductors for Resonance Phenomenon and Transient Response in JT-60SA Central Solenoid
An inhomogeneous voltage distribution in the coil is induced by the resonance phenomenon and transient response caused by the power supply. Therefore, damage to the insulation between conductors in the coils is possible. We created the circuit simulation models of the CS module (the 52-layer pancake coil) with the room-temperature busbar and superconducting current feeder between the power supply and CS module. Then, we evaluated the behavior of the voltage between the conductors for the resonance phenomenon and transient response caused by the supply voltage in the CS module. Based on the results, we can conclude that the influences of resonance phenomenon and transient response on the voltage between the conductors in the CS module is negligibly small under the expected operating conditions. These results therefore represent important information for the safe operation of the JT-60SA.
- 4 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-5
Evaluation of Voltage Between Conductors for Resonance Phenomenon and Transient Response in JT-60SA Central Solenoid
An inhomogeneous voltage distribution in the coil is induced by the resonance phenomenon and transient response caused by the power supply. Therefore, damage to the insulation between conductors in the coils is possible. We created the circuit simulation models of the CS module (the 52-layer pancake coil) with the room-temperature busbar and superconducting current feeder between the power supply and CS module. Then, we evaluated the behavior of the voltage between the conductors for the resonance phenomenon and transient response caused by the supply voltage in the CS module. Based on the results, we can conclude that the influences of resonance phenomenon and transient response on the voltage between the conductors in the CS module is negligibly small under the expected operating conditions. These results therefore represent important information for the safe operation of the JT-60SA.