Nicole Glamann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nicole Glamann has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Grau
Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
3 shared publications - Sara Casalbuoni
European XFEL GmbH, Schenefeld, Germany
3 shared publications - Cristian Boffo
Babcock Noell GmbH, Wurzburg, Germany
2 shared publications - David Saez de Jauregui
Karlsruhe Institute of Technology, Karlsruhe, Germany
2 shared publications - Melanie Turenne
Magnet Technologies, Babcock Noell GmbH, 500245 Wurzburg, Bayern Germany
2 shared publications - Thomas Gerhard
Magnet Technologies, Babcock Noell GmbH, Wurzburg, Bayern Germany
2 shared publications
Latest Publications
- Open Access
- 2 June 2025
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (4) , 908-918
Design and commissioning of the first superconducting undulator for the BioSAXS beamline at the Australian Synchrotron
A 1.6 m-long 16 mm-period superconducting undulator (SCU16) has been installed and commissioned at the Australian Synchrotron. The SCU16, developed by Bilfinger, is based on the SCU20 currently operating at Karlsruhe Institute of Technology (KIT). The SCU16 is conduction cooled with a maximum on-axis field of 1.084 T and a fixed effective vacuum gap of 5.5 mm. The design, commissioning experience and performance of one of the longest superconducting undulators at a light source are presented.
- 2 June 2025
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (4) , 908-918
Open AccessDesign and commissioning of the first superconducting undulator for the BioSAXS beamline at the Australian Synchrotron
A 1.6 m-long 16 mm-period superconducting undulator (SCU16) has been installed and commissioned at the Australian Synchrotron. The SCU16, developed by Bilfinger, is based on the SCU20 currently operating at Karlsruhe Institute of Technology (KIT). The SCU16 is conduction cooled with a maximum on-axis field of 1.084 T and a fixed effective vacuum gap of 5.5 mm. The design, commissioning experience and performance of one of the longest superconducting undulators at a light source are presented.
- 11 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-4
Full-Scale Conduction-Cooled Superconducting Undulator Coils—Training, Stability, and Thermal Behavior
Since several years the Institute for Beam Physics and Technology (IBPT) of the Karlsruhe Institute of Technology (KIT) is collaborating with its industrial partner Babcock Noell GmbH (BNG) in a R&D program on superconducting undulators (SCUs). At present the collaboration is primarily working on a SCU with a period length of 20 mm (SCU20). This device is foreseen to be installed at ANKA, the test facility and synchrotron radiation source, run by the IBPT. The 1.5 m long undulator coils have been tested in a horizontal, conduction - cooled measurement setup. This contribution describes the training, the stability and the thermal behavior of the coils.
- 11 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-4
Full-Scale Conduction-Cooled Superconducting Undulator Coils—Training, Stability, and Thermal Behavior
Since several years the Institute for Beam Physics and Technology (IBPT) of the Karlsruhe Institute of Technology (KIT) is collaborating with its industrial partner Babcock Noell GmbH (BNG) in a R&D program on superconducting undulators (SCUs). At present the collaboration is primarily working on a SCU with a period length of 20 mm (SCU20). This device is foreseen to be installed at ANKA, the test facility and synchrotron radiation source, run by the IBPT. The 1.5 m long undulator coils have been tested in a horizontal, conduction - cooled measurement setup. This contribution describes the training, the stability and the thermal behavior of the coils.
- 11 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-4
Magnetic Field Measurements of Full-Scale Conduction-Cooled Superconducting-Undulator-Coils
The Institute for Beam Physics and Technology (IBPT) of the Karlsruhe Institute of Technology (KIT) and Babcock Noell GmbH (BNG) are collaborating to develop superconducting undulators for ANKA and low emittance light sources. The collaboration is now focusing on a superconducting undulator with a period length of 20 mm (SCU20) planned to be the source of the NANO beamline at ANKA. The local magnetic field and the field integrals of the SCU20 1.5 m-long-coils have been characterized in a conduction cooled horizontal test facility developed at KIT IBPT. Here we complement the main results reported in a previous work with a more detailed analysis, including the measurements of the geometrical deviations from the ideal case of the undulator coils at room temperature used to simulate the magnetic field profile with the program Radia and a quantitative explanation of the magnetic field measurements in cold conditions. A comparison of the photon spectrum calculated from the measured field with the one from the field simulated with Radia considering the geometry measured at room temperature is also presented.
- 11 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-4
Magnetic Field Measurements of Full-Scale Conduction-Cooled Superconducting-Undulator-Coils
The Institute for Beam Physics and Technology (IBPT) of the Karlsruhe Institute of Technology (KIT) and Babcock Noell GmbH (BNG) are collaborating to develop superconducting undulators for ANKA and low emittance light sources. The collaboration is now focusing on a superconducting undulator with a period length of 20 mm (SCU20) planned to be the source of the NANO beamline at ANKA. The local magnetic field and the field integrals of the SCU20 1.5 m-long-coils have been characterized in a conduction cooled horizontal test facility developed at KIT IBPT. Here we complement the main results reported in a previous work with a more detailed analysis, including the measurements of the geometrical deviations from the ideal case of the undulator coils at room temperature used to simulate the magnetic field profile with the program Radia and a quantitative explanation of the magnetic field measurements in cold conditions. A comparison of the photon spectrum calculated from the measured field with the one from the field simulated with Radia considering the geometry measured at room temperature is also presented.