Debao Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Debao Zhou has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Jing Bai
Department of Electrical Engineering, University of Minnesota Duluth, Duluth, MN, USA
3 shared publications- Jing Bai
CCDC Drilling & Production Technology Research Insititute No.88 Zhongshan Road, Guanghan, Sichuan Province, China
2 shared publications Changyun Miao
School of Electronic and Information Engineering, Tiangong University, Tianjin, China
1 shared publicationEliah J. Hauser
Department of Mechanical and Industrial Engineering, University of Minnesota, Duluth, MN, USA
1 shared publicationHaopeng Wang
University of Minnesota Duluth
1 shared publicationJianguo Cao
University of Science and Technology Beijing
1 shared publication
Latest Publications
- 21 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (20) , 31806-31815
A Flexible Pressure Sensor With Parallel Fiber Structure for Wireless Capsule Detection
With the rapid development of science and technology, flexible pressure sensors with high sensitivity and excellent stability have generated considerable attention due to their potential applications. However, the challenge of achieving high sensitivity persists in the development of pressure sensors. Polyaniline (PANI) has been widely used in various fields as a sensing material owing to its simple preparation and good electrical conductivity. In this study, a pressure sensor with a sandwich structure was developed to sensitively monitor body signals. The micro-nanofiber mats were prepared by electrospinning of thermoplastic polyurethane (TPU). The constructed parallel TPU mats (P-TPU) and staggered TPU mats (S-TPU) possess a non-woven structure with a fiber diameter of (0.68±0.14) μm and (1.02±0.24) μm, respectively. PANI was grown in situ on the mat to form a conductive layer. After stacking S-TPU fiber mats bonded with commercial medical polyurethane (PU) films and orderly conductive mats to form a PANI-coated mat/S-TPU mat structure, another layer of the S-TPU mats was also packed for the construction of a sandwich-structured piezoresistive sensor. The device could tolerate more than 10,000 pressing cycles without affecting its sensing capability. The human body-attached experiments further demonstrated that the sensor could real-time monitor actions of finger/arm bending, cheek swelling and holding their breath, speaking-caused throat vibration, and moving of the gastrointestinal tract. The electrospinning method could be used as a cost-effective strategy with a simple preparation process to obtain flexible piezoresistive sensors with good skin compatibility and powerful pressure-sensing capabilities.
- 21 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (20) , 31806-31815
A Flexible Pressure Sensor With Parallel Fiber Structure for Wireless Capsule Detection
With the rapid development of science and technology, flexible pressure sensors with high sensitivity and excellent stability have generated considerable attention due to their potential applications. However, the challenge of achieving high sensitivity persists in the development of pressure sensors. Polyaniline (PANI) has been widely used in various fields as a sensing material owing to its simple preparation and good electrical conductivity. In this study, a pressure sensor with a sandwich structure was developed to sensitively monitor body signals. The micro-nanofiber mats were prepared by electrospinning of thermoplastic polyurethane (TPU). The constructed parallel TPU mats (P-TPU) and staggered TPU mats (S-TPU) possess a non-woven structure with a fiber diameter of (0.68±0.14) μm and (1.02±0.24) μm, respectively. PANI was grown in situ on the mat to form a conductive layer. After stacking S-TPU fiber mats bonded with commercial medical polyurethane (PU) films and orderly conductive mats to form a PANI-coated mat/S-TPU mat structure, another layer of the S-TPU mats was also packed for the construction of a sandwich-structured piezoresistive sensor. The device could tolerate more than 10,000 pressing cycles without affecting its sensing capability. The human body-attached experiments further demonstrated that the sensor could real-time monitor actions of finger/arm bending, cheek swelling and holding their breath, speaking-caused throat vibration, and moving of the gastrointestinal tract. The electrospinning method could be used as a cost-effective strategy with a simple preparation process to obtain flexible piezoresistive sensors with good skin compatibility and powerful pressure-sensing capabilities.
- 4 June 2020
- Published by Taylor & Francis in Materials Research Innovations
- Vol. 25 (3) , 162-168
A study of conductive thermoplastic elastomeric polyurethane and graphene nanocomposite thin films for application to flexible electrical sensors
Pressure-sensitive thin film is one of the major components in flexible electrical sensors (e-skin sensors). The thin film are normally conductive and durable. However, its applications are often limited, due to its big noise and hysteresis. In this research, we developed a new nanocomposite made with thermoplastic-polyurethane (TPU) and graphene to measure contact pressure. To ensure a minimum noise level in the measurement, we prepared it through an iterative heating, sonication, and phase inversion process. Then we studied the relationship between the measured resistance and applied force through the comprehensive consideration of the graphene weight percentage, the size of the sensing elements, and the loading/unloading speed. We also characterised its hysteresis and repeatability. Finally, the nanocomposite with the best comprehensive results was selected and stencil-printed in the holes on a polydimethylsiloxane film to be used as the sensing element of e-skin sensors.
- 4 June 2020
- Published by Taylor & Francis in Materials Research Innovations
- Vol. 25 (3) , 162-168
A study of conductive thermoplastic elastomeric polyurethane and graphene nanocomposite thin films for application to flexible electrical sensors
Pressure-sensitive thin film is one of the major components in flexible electrical sensors (e-skin sensors). The thin film are normally conductive and durable. However, its applications are often limited, due to its big noise and hysteresis. In this research, we developed a new nanocomposite made with thermoplastic-polyurethane (TPU) and graphene to measure contact pressure. To ensure a minimum noise level in the measurement, we prepared it through an iterative heating, sonication, and phase inversion process. Then we studied the relationship between the measured resistance and applied force through the comprehensive consideration of the graphene weight percentage, the size of the sensing elements, and the loading/unloading speed. We also characterised its hysteresis and repeatability. Finally, the nanocomposite with the best comprehensive results was selected and stencil-printed in the holes on a polydimethylsiloxane film to be used as the sensing element of e-skin sensors.
- 6 November 2018
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 22 (1) , 38-46
Numerical evaluation of the efficacy of small-caliber colonoscopes in reducing patient pain during a colonoscopy
Patient pain caused by a colonoscope is one of the main complications in completing a colonoscopy. Currently, randomized controlled trial (RCT) is one of the most used methods to evaluate the efficacy of small-caliber (SC) colonoscopes in reducing patient pain during a colonoscopy, compared with a standard colonoscope (SDC). However, many disturbing factors, including endoscopists’ skills, characteristics of patients and new technical features of the colonoscope (passive bending and high force transmission shaft), limit the reliability and generalizability of each finding in current RCTs. This paper focuses on modeling the insertion of colonoscopes within colon models using an explicit finite element method (FEM). Such a numerical model could overcome the limitations in RCTs. At the same time, it is expected to evaluate the efficacy of the small-caliber colonoscopes in reducing patient pain during a colonoscopy, while considering the effects of patient characteristics, including age, region and gender. The simulation results in this work showed that: compared with the SDC, a SC colonoscope may be more helpful in reducing discomfort for older patients, patients with smaller colon diameters and females.
- 6 November 2018
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 22 (1) , 38-46
Numerical evaluation of the efficacy of small-caliber colonoscopes in reducing patient pain during a colonoscopy
Patient pain caused by a colonoscope is one of the main complications in completing a colonoscopy. Currently, randomized controlled trial (RCT) is one of the most used methods to evaluate the efficacy of small-caliber (SC) colonoscopes in reducing patient pain during a colonoscopy, compared with a standard colonoscope (SDC). However, many disturbing factors, including endoscopists’ skills, characteristics of patients and new technical features of the colonoscope (passive bending and high force transmission shaft), limit the reliability and generalizability of each finding in current RCTs. This paper focuses on modeling the insertion of colonoscopes within colon models using an explicit finite element method (FEM). Such a numerical model could overcome the limitations in RCTs. At the same time, it is expected to evaluate the efficacy of the small-caliber colonoscopes in reducing patient pain during a colonoscopy, while considering the effects of patient characteristics, including age, region and gender. The simulation results in this work showed that: compared with the SDC, a SC colonoscope may be more helpful in reducing discomfort for older patients, patients with smaller colon diameters and females.
- 26 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (6) , 2291-2298
Test of a Tube-Shaped Artificial Skin Sensor Array for Colonoscopies
Thin-film stretchable sensors are believed to have great applications on devices with curved surfaces. As one type of these sensors, electronic skins (e-skins) for pressure measurement have the potential to provide protection to the human body by feeding back the contact pressure. One of the applications is to monitor the contact pressure from a colonoscope to the colonic wall during a colonoscopy to prevent perforation and hemorrhaging. Many studies have reported the highly flexible and stretchable nature of e-skin sensors. However, no effort has been made to investigate their performance in a colon simulator. In this work, we developed a new technique to make ultra-thin, highly stretchable electrodes on thin films. Then we successfully built a three-layer tube-shaped tactile sensor with high conformability and stretchability. We then investigated the pressure generated by various bending curvatures on a colonoscope. Finally, we performed a real-time pressure measurement with the whole sensing system on a fake colonoscope in a colon-simulator. The measured pressure was obtained and visualized on a computer screen. These experiments validated the applicability of the designed sensor and revealed the actual stress distribution on a tube-shaped e-skin sensor array in a colon-simulator. This research could be the starting point of the effort to upgrade the strategies of colonoscopy for safer operations and could provide new routines to optimize tactile sensor design for other medical applications.
- 26 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (6) , 2291-2298
Test of a Tube-Shaped Artificial Skin Sensor Array for Colonoscopies
Thin-film stretchable sensors are believed to have great applications on devices with curved surfaces. As one type of these sensors, electronic skins (e-skins) for pressure measurement have the potential to provide protection to the human body by feeding back the contact pressure. One of the applications is to monitor the contact pressure from a colonoscope to the colonic wall during a colonoscopy to prevent perforation and hemorrhaging. Many studies have reported the highly flexible and stretchable nature of e-skin sensors. However, no effort has been made to investigate their performance in a colon simulator. In this work, we developed a new technique to make ultra-thin, highly stretchable electrodes on thin films. Then we successfully built a three-layer tube-shaped tactile sensor with high conformability and stretchability. We then investigated the pressure generated by various bending curvatures on a colonoscope. Finally, we performed a real-time pressure measurement with the whole sensing system on a fake colonoscope in a colon-simulator. The measured pressure was obtained and visualized on a computer screen. These experiments validated the applicability of the designed sensor and revealed the actual stress distribution on a tube-shaped e-skin sensor array in a colon-simulator. This research could be the starting point of the effort to upgrade the strategies of colonoscopy for safer operations and could provide new routines to optimize tactile sensor design for other medical applications.
- 1 January 2015
- Published by Optica Publishing Group
- Vol. 15, NW4A.11
Stability Analysis of Quantum-Cascade Lasers with Intracavity Nonlinearity and Group-Velocity Dispersion
Both amplitude and phase instabilities of mid-infrared quantum-cascade lasers were analyzed in the presence of group-velocity dispersion and a background saturable absorber in the lasing medium. The effect of group-velocity dispersion is found to be more significant at lower pumping level and with a weaker saturable absorber.
- 1 January 2015
- Published by Optica Publishing Group
- Vol. 15, NW4A.11
Stability Analysis of Quantum-Cascade Lasers with Intracavity Nonlinearity and Group-Velocity Dispersion
Both amplitude and phase instabilities of mid-infrared quantum-cascade lasers were analyzed in the presence of group-velocity dispersion and a background saturable absorber in the lasing medium. The effect of group-velocity dispersion is found to be more significant at lower pumping level and with a weaker saturable absorber.
- 12 September 2014
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 23 (10) , 104001
Effects of oxygen plasma treatment and e-beam evaporation on AgNWs/PDMS based stretchable electrode
- 12 September 2014
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 23 (10) , 104001
Effects of oxygen plasma treatment and e-beam evaporation on AgNWs/PDMS based stretchable electrode
- 1 January 2014
- Published by ACTA Press in International Journal of Modelling and Simulation
- Vol. 34 (4)
CONTACT EFFECT EVALUATION USING STRESS DISTRIBUTION IN VISCOELASTIC MATERIAL UNDER GENERALIZED LOADING
- 1 January 2014
- Published by ACTA Press in International Journal of Modelling and Simulation
- Vol. 34 (4)
CONTACT EFFECT EVALUATION USING STRESS DISTRIBUTION IN VISCOELASTIC MATERIAL UNDER GENERALIZED LOADING