Sun Pengshuai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sun Pengshuai has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Bian Wu
Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Hefei Inst Phys Sci, Anhui Prov Key Lab Photon Devices & Mat, Hefei 230031, Peoples R China
4 shared publications - Hua Xia
Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Hefei Inst Phys Sci, Anhui Prov Key Lab Photon Devices & Mat, Hefei 230031, Peoples R China
4 shared publications - Zhirong Zhang
Anhui Provincial Key Laboratory of Photonic Devices and Materials, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China
4 shared publications - Lewen Zhang
School of Electronic and Information Engineering, Hefei Institute of Technology, Hefei 238076, China
2 shared publications - Liu Xu
School of Electronic and Electrical Engineering, Bengbu University, Bengbu 233030, China
2 shared publications - Pang Tao
Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Hefei Inst Phys Sci, Anhui Prov Key Lab Photon Devices & Mat, Hefei 230031, Peoples R China
2 shared publications
Latest Publications
- Open Access
Development of a Rapid Measurement Method for Analysis of the NOx Conversion Process Based on Quantum Cascade Laser Absorption Spectroscopy
In this study, a method for double-beam quantum cascade laser absorption spectroscopy (DB-QCLAS) was developed. Two mid-infrared distributed feedback quantum cascade laser beams were coupled in an optical cavity for the monitoring of NO and NO2 (NO at 5.26 μm; NO2 at 6.13 μm). Appropriate lines in the absorption spectra were selected, and the influence of common gases in the atmosphere, such as H2O and CO2, was avoided. By analyzing the spectral lines under different pressure conditions, the appropriate measurement pressure of 111 mbar was selected. Under this pressure, the interference between adjacent spectral lines could be effectively distinguished. The experimental results show that the standard deviations for NO and NO2 were 1.57 ppm and 2.67 ppm, respectively. Moreover, in order to improve the feasibility of this technology for detecting chemical reactions between NO and O2, the standard gases of NO and O2 were used to fill the cavity. A chemical reaction instantaneously began, and the concentrations of the two gases were immediately changed. Through this experiment, we hope to develop new ideas for the accurate and rapid analysis of the process of NOx conversion and to lay a foundation for a deeper understanding of the chemical changes in atmospheric environments.
Open AccessDevelopment of a Rapid Measurement Method for Analysis of the NOx Conversion Process Based on Quantum Cascade Laser Absorption Spectroscopy
In this study, a method for double-beam quantum cascade laser absorption spectroscopy (DB-QCLAS) was developed. Two mid-infrared distributed feedback quantum cascade laser beams were coupled in an optical cavity for the monitoring of NO and NO2 (NO at 5.26 μm; NO2 at 6.13 μm). Appropriate lines in the absorption spectra were selected, and the influence of common gases in the atmosphere, such as H2O and CO2, was avoided. By analyzing the spectral lines under different pressure conditions, the appropriate measurement pressure of 111 mbar was selected. Under this pressure, the interference between adjacent spectral lines could be effectively distinguished. The experimental results show that the standard deviations for NO and NO2 were 1.57 ppm and 2.67 ppm, respectively. Moreover, in order to improve the feasibility of this technology for detecting chemical reactions between NO and O2, the standard gases of NO and O2 were used to fill the cavity. A chemical reaction instantaneously began, and the concentrations of the two gases were immediately changed. Through this experiment, we hope to develop new ideas for the accurate and rapid analysis of the process of NOx conversion and to lay a foundation for a deeper understanding of the chemical changes in atmospheric environments.
- 12 September 2022
- Published by HARD Publishing Company in Polish Journal of Environmental Studies
- Vol. 31 (6) , 5343-5352
Identification and Control Method of Temperature and Pressure Control System in Methane Isotope Measurement System
At present, gas monitoring technology based on optical principle has been widely used in atmospheric environment, industrial emissions, smart city and other monitoring fields. For the requirement of high precision and high stability control of temperature and pressure of laser absorption spectroscopy measuring instrument, the temperature and pressure control scheme of the system is studied. The temperature and pressure control system is identified and the simulation model is established. The consistency of temperature and pressure models is 99.35% and 95.55% by using Process Models module to debug continuously. The simulation compares the output response curves of different control methods with the same step signal input, and the Fuzzy Adaptive PID parameter control algorithm achieves the design requirements in response time, overshoot and other aspects.
- 12 September 2022
- Published by HARD Publishing Company in Polish Journal of Environmental Studies
- Vol. 31 (6) , 5343-5352
Identification and Control Method of Temperature and Pressure Control System in Methane Isotope Measurement System
At present, gas monitoring technology based on optical principle has been widely used in atmospheric environment, industrial emissions, smart city and other monitoring fields. For the requirement of high precision and high stability control of temperature and pressure of laser absorption spectroscopy measuring instrument, the temperature and pressure control scheme of the system is studied. The temperature and pressure control system is identified and the simulation model is established. The consistency of temperature and pressure models is 99.35% and 95.55% by using Process Models module to debug continuously. The simulation compares the output response curves of different control methods with the same step signal input, and the Fuzzy Adaptive PID parameter control algorithm achieves the design requirements in response time, overshoot and other aspects.
- 20 December 2021
- Published by HARD Publishing Company in Polish Journal of Environmental Studies
- Vol. 31 (1) , 969-978
Design of High Precision Temperature and Pressure Closed-Loop Control System for Methane Carbon Isotope Ratio Measurement by Laser Absorption Spectroscopy
In order to achieve the accurate measurement of gas stable isotope, according to the structure of gas cavity and the characteristics of optical elements, a constant temperature and pressure gas isotope measurement experimental system based on tunable diode laser absorption spectroscopy (TDLAS) technology is designed, which can achieve high-precision and stable control of temperature and pressure in the box. The hardware circuit system including high-precision constant-current source, two-channel temperature sampling module, conditioning circuit and pressure control circuit is designed in the system. The corresponding system closed-loop control software is developed to ensure the stability of the temperature and pressure of the optical cavity. Through the experimental verification, the temperature is controlled at 35ºC and the pressure is controlled at 150 mbar in the present work. The measurement results verified the stability of the temperature and pressure system, as follows: the optimal temperature fluctuation control is ±0.005ºC and the pressure stability is ±0.1 mbar. Then, in our experiment, the CH4 standard gas is introduced to measure carbon isotope (12CH4 and 13CH4). The results clearly show that the control system is sufficiently stable to be used and the δ13C value can reach 0.52‰ according to the Allan variance.
- 20 December 2021
- Published by HARD Publishing Company in Polish Journal of Environmental Studies
- Vol. 31 (1) , 969-978
Design of High Precision Temperature and Pressure Closed-Loop Control System for Methane Carbon Isotope Ratio Measurement by Laser Absorption Spectroscopy
In order to achieve the accurate measurement of gas stable isotope, according to the structure of gas cavity and the characteristics of optical elements, a constant temperature and pressure gas isotope measurement experimental system based on tunable diode laser absorption spectroscopy (TDLAS) technology is designed, which can achieve high-precision and stable control of temperature and pressure in the box. The hardware circuit system including high-precision constant-current source, two-channel temperature sampling module, conditioning circuit and pressure control circuit is designed in the system. The corresponding system closed-loop control software is developed to ensure the stability of the temperature and pressure of the optical cavity. Through the experimental verification, the temperature is controlled at 35ºC and the pressure is controlled at 150 mbar in the present work. The measurement results verified the stability of the temperature and pressure system, as follows: the optimal temperature fluctuation control is ±0.005ºC and the pressure stability is ±0.1 mbar. Then, in our experiment, the CH4 standard gas is introduced to measure carbon isotope (12CH4 and 13CH4). The results clearly show that the control system is sufficiently stable to be used and the δ13C value can reach 0.52‰ according to the Allan variance.
- 18 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 37 (11) , 2784-2791
Development of a Quantum Cascade Laser-Based Sensor for Environmental HONO Monitoring in the Mid-Infrared at 8 μm
The development of a fast in situ optical sensor based on a continuous-wave (cw) quantum cascade laser (QCL) operating at 8 μm for measurement of environmental gaseous nitrous acid (HONO) is reported. A strong absorption line at 1252.2109 cm $^{-1}$ is found to be free of interferences and used for the first time for ambient HONO detection. Loss of HONO on the wall of the gas sample absorption cell is evaluated. The resulting 1-s detection limit for HONO is 110 pptv with a folded path length of 172 m. Continuous monitoring of HONO and NO2 mixing ratios variations along with the basic meteorological parameters were performed during a field campaign of several days. Typical photochemical reactions of HONO have been observed on sunny and snowy days. Atmospheric HONO mixing ratios observed in this study indicate that direct emission from traffic exhausts and local heterogeneous reactions are potentially important sources of HONO.- 18 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 37 (11) , 2784-2791
Development of a Quantum Cascade Laser-Based Sensor for Environmental HONO Monitoring in the Mid-Infrared at 8 μm
The development of a fast in situ optical sensor based on a continuous-wave (cw) quantum cascade laser (QCL) operating at 8 μm for measurement of environmental gaseous nitrous acid (HONO) is reported. A strong absorption line at 1252.2109 cm $^{-1}$ is found to be free of interferences and used for the first time for ambient HONO detection. Loss of HONO on the wall of the gas sample absorption cell is evaluated. The resulting 1-s detection limit for HONO is 110 pptv with a folded path length of 172 m. Continuous monitoring of HONO and NO2 mixing ratios variations along with the basic meteorological parameters were performed during a field campaign of several days. Typical photochemical reactions of HONO have been observed on sunny and snowy days. Atmospheric HONO mixing ratios observed in this study indicate that direct emission from traffic exhausts and local heterogeneous reactions are potentially important sources of HONO.