John Stang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
John Stang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Agostino Monorchio
Department of Information Engineering, University of Pisa, 56122 Pisa, Italy
1 shared publication - Danilo Brizi
Department of Information Engineering, University of Pisa, 56122 Pisa, Italy
1 shared publication - Gianluca Lazzi
University of Southern California, 5116 LOS ANGELES, California United States
1 shared publication - Gianluca Lazzi
University of Southern California
1 shared publication - Guanbo Chen
University of Southern California, Los Angeles, California United States
1 shared publication - Javad Paknahad
Department of Electrical Engineering, University of Southern California, Los Angeles, CA, USA
1 shared publication
Latest Publications
- 1 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 68 (9) , 3814-3822
On the Design of Planar Arrays of Nonresonant Coils for Tunable Wireless Power Transfer Applications
In this article, we introduce a novel array-based system for inductive wireless power transfer (WPT) applications and a procedure for its design, which can be interpreted as a generalization of the traditional three-coil systems where the intermediate passive resonant coil (i.e., the transmitter) is replaced with an array of nonresonant concentric loops. We demonstrate that the new WPT array system provides flexibility with respect to the characteristic parameters of the inductive link (i.e., efficiency and gain), thus allowing for their optimal tradeoff depending on the specific WPT application: this is achieved by controlling the current amplitude flowing in each element of the array through the addition of an appropriately selected reactive load. Furthermore, we demonstrate that it is possible to obtain, with the WPT array, focused magnetic field distributions, leading to a potential reduction in the receiver dimensions. Such configuration can be made effectively equivalent to a traditional three-coil system in terms of physical dimensions and performance, through the addition of an appropriate reactance to each loop of the array. To demonstrate the validity and usefulness of the proposed system and design procedure, we first performed extensive numerical simulations of a traditional three-coil system and compared its performance with different array configurations. We then fabricated and experimentally characterized several prototypes, observing an excellent agreement between the measurements and simulations. The innovative features of the proposed design can be extremely useful in many WPT applications requiring a fine optimization in efficiency, gain, and field distribution.
- 1 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 68 (9) , 3814-3822
On the Design of Planar Arrays of Nonresonant Coils for Tunable Wireless Power Transfer Applications
In this article, we introduce a novel array-based system for inductive wireless power transfer (WPT) applications and a procedure for its design, which can be interpreted as a generalization of the traditional three-coil systems where the intermediate passive resonant coil (i.e., the transmitter) is replaced with an array of nonresonant concentric loops. We demonstrate that the new WPT array system provides flexibility with respect to the characteristic parameters of the inductive link (i.e., efficiency and gain), thus allowing for their optimal tradeoff depending on the specific WPT application: this is achieved by controlling the current amplitude flowing in each element of the array through the addition of an appropriately selected reactive load. Furthermore, we demonstrate that it is possible to obtain, with the WPT array, focused magnetic field distributions, leading to a potential reduction in the receiver dimensions. Such configuration can be made effectively equivalent to a traditional three-coil system in terms of physical dimensions and performance, through the addition of an appropriate reactance to each loop of the array. To demonstrate the validity and usefulness of the proposed system and design procedure, we first performed extensive numerical simulations of a traditional three-coil system and compared its performance with different array configurations. We then fabricated and experimentally characterized several prototypes, observing an excellent agreement between the measurements and simulations. The innovative features of the proposed design can be extremely useful in many WPT applications requiring a fine optimization in efficiency, gain, and field distribution.
- 28 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 19 (4) , 690-694
Wireless Telemetry System With Independent Power and Data Frequency Resonance
Wireless power and data transmission systems are important components in bio-electronics. Achieving resonance at the data transmission frequency without negatively impacting the efficiency at the power transmission frequency may enhance data transmission capability. In this work, a new system referred to as Tuned Inductor Four Capacitor (TL4C) is proposed to achieve resonance at the data transmission frequency of a wireless telemetry system without significantly affecting the efficiency at the power transmit frequency; as a result, this leads to increased voltage and current gains and reduced reflections at the data transmit frequency when compared to an equivalent, traditional, two-coil system. The performance of the proposed design is demonstrated through a system implementation characterized by a transmit coil of 40 mm diameter and receive coil of 15 mm diameter, with a distance between them varied from 17 mm to 40 mm. This system is experimentally compared with the equivalent two-coil system that has the same transmit and receive coil footprint and layout but conventional transmitter matching circuitry: results show that, at the data telemetry frequency, there is no reflection, the voltage gain is 60% higher than that of the traditional two coil system, while the current gain is 250% higher.
- 28 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 19 (4) , 690-694
Wireless Telemetry System With Independent Power and Data Frequency Resonance
Wireless power and data transmission systems are important components in bio-electronics. Achieving resonance at the data transmission frequency without negatively impacting the efficiency at the power transmission frequency may enhance data transmission capability. In this work, a new system referred to as Tuned Inductor Four Capacitor (TL4C) is proposed to achieve resonance at the data transmission frequency of a wireless telemetry system without significantly affecting the efficiency at the power transmit frequency; as a result, this leads to increased voltage and current gains and reduced reflections at the data transmit frequency when compared to an equivalent, traditional, two-coil system. The performance of the proposed design is demonstrated through a system implementation characterized by a transmit coil of 40 mm diameter and receive coil of 15 mm diameter, with a distance between them varied from 17 mm to 40 mm. This system is experimentally compared with the equivalent two-coil system that has the same transmit and receive coil footprint and layout but conventional transmitter matching circuitry: results show that, at the data telemetry frequency, there is no reflection, the voltage gain is 60% higher than that of the traditional two coil system, while the current gain is 250% higher.
- 2 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 5 (1) , 97-108
3-D Level Set Method for Joint Contrast and Shape Recovery in Microwave Imaging
We propose a 3D fast level set method, which can estimate both object shape and dielectric contrast with reduced computational cost. In prior work, we presented a 2D fast level set method that integrated the level set inversion within the Born Iterative Method (BIM). That approach significantly reduced the computational cost; however, it was limited to estimating object shape without providing any dielectric contrast inversion. In this work, we extend our previous method to 3D and add the capability to estimate dielectric contrast in addition to the shape. The contrast estimation is formulated as a separate step within the BIM iteration, such that shape and contrast are estimated sequentially in each BIM iteration. This modular framework enables the freedom to choose any arbitrary constraints on the contrast in the cost function. Here, we demonstrate the applicability of a total-variation (TV) constraint for the contrast cost function. To validate the method, synthetic data are generated for objects within a three-dimensional imaging cavity and are then used to test for robustness against variations in object shape, size, position, and contrast. Further, the method is tested on MRI-derived numerical breast phantoms. The reconstructed images indicate that the method can produce accurate estimates of object location, shape, and size while recovering the contrast with an error lower than $2\%$ .- 2 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 5 (1) , 97-108
3-D Level Set Method for Joint Contrast and Shape Recovery in Microwave Imaging
We propose a 3D fast level set method, which can estimate both object shape and dielectric contrast with reduced computational cost. In prior work, we presented a 2D fast level set method that integrated the level set inversion within the Born Iterative Method (BIM). That approach significantly reduced the computational cost; however, it was limited to estimating object shape without providing any dielectric contrast inversion. In this work, we extend our previous method to 3D and add the capability to estimate dielectric contrast in addition to the shape. The contrast estimation is formulated as a separate step within the BIM iteration, such that shape and contrast are estimated sequentially in each BIM iteration. This modular framework enables the freedom to choose any arbitrary constraints on the contrast in the cost function. Here, we demonstrate the applicability of a total-variation (TV) constraint for the contrast cost function. To validate the method, synthetic data are generated for objects within a three-dimensional imaging cavity and are then used to test for robustness against variations in object shape, size, position, and contrast. Further, the method is tested on MRI-derived numerical breast phantoms. The reconstructed images indicate that the method can produce accurate estimates of object location, shape, and size while recovering the contrast with an error lower than $2\%$ .