Jun Zhang
Jun Zhang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Caiyi Fang
Product Center, Brainware Terahertz Information Technology Co. Ltd., Hefei, Anhui China
1 shared publication - Can Fang
Product Center, Brainware Terahertz Information Technology Co. Ltd., Hefei, Anhui China
1 shared publication - Hao Tu
Hefei University of Technology
1 shared publication - Huakun Zhang
Product Center, Brainware Terahertz Information Technology Co. Ltd., Hefei, Anhui China
1 shared publication - Lin Chen
Research Center, Brainware Terahertz Information Technology Co. Ltd., Hefei, Anhui China
1 shared publication - Puqiong Yang
University of South China
1 shared publication
Latest Publications
- Open Access
- 6 February 2026
- Published by MDPI AG in Preprints.org
Development of a Multi-Channel Low-Noise Microcurrent Data Acquisition System Based on ZYNQ
To meet the requirements for high-precision acquisition of multi-channel weak current signals in magnetic field tomography diagnostics for the CN-H1 star-simulator, this paper presents a 64-channel microcurrent data acquisition system based on the ZYNQ-7000 SoC. The system employs independent high-gain transimpedance amplification and filtering circuits for front-end conditioning. Utilising FPGA control over four AD4115 analogue-to-digital converters, it achieves parallel high-precision acquisition of 64 signals. Experiments demonstrate that within the ±2 μA input range, the system's equivalent input noise remains below 0.2 nA (RMS). The average effective number of bits (ENOB) per channel reaches 13.28 bits, with high inter-channel consistency (standard deviation of 0.04 bits). This system combines high channel density with outstanding single-channel measurement performance, making it suitable for precision measurement scenarios requiring parallel, high-precision acquisition of minute currents.
- 6 February 2026
- Published by MDPI AG in Preprints.org
Open AccessDevelopment of a Multi-Channel Low-Noise Microcurrent Data Acquisition System Based on ZYNQ
To meet the requirements for high-precision acquisition of multi-channel weak current signals in magnetic field tomography diagnostics for the CN-H1 star-simulator, this paper presents a 64-channel microcurrent data acquisition system based on the ZYNQ-7000 SoC. The system employs independent high-gain transimpedance amplification and filtering circuits for front-end conditioning. Utilising FPGA control over four AD4115 analogue-to-digital converters, it achieves parallel high-precision acquisition of 64 signals. Experiments demonstrate that within the ±2 μA input range, the system's equivalent input noise remains below 0.2 nA (RMS). The average effective number of bits (ENOB) per channel reaches 13.28 bits, with high inter-channel consistency (standard deviation of 0.04 bits). This system combines high channel density with outstanding single-channel measurement performance, making it suitable for precision measurement scenarios requiring parallel, high-precision acquisition of minute currents.
- 4 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 9 (3) , 253-261
A Fast 220-GHz Real Aperture 3-D Personnel Screening System With a Novel-Shaped Mirror Design
Terahertz systems have attracted much attention recently in the field of public security due to the high penetration of terahertz waves through clothes and the high resolution of terahertz images. A novel real aperture terahertz personnel screening system is demonstrated in this work. This system uses a single transmitter and receiver pair together with a quasi-optical system to irradiate and collect the terahertz waves. In the quasi-optical system, a novel design of a shaped reflector used as the main mirror helps reach a satisfying focus and meanwhile keep the beam direction invariant. By using this main mirror and a hexagonal cylindrical scanning mirror, a fast horizontal scan of 0.6m field of view can be accomplished withing 10 milliseconds. The vertical scan is realized by a customized translation stage. The whole system is able to finish a whole-body scan of a person within 2.9s with a cross-section resolution of less than 8mm.
- 4 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 9 (3) , 253-261
A Fast 220-GHz Real Aperture 3-D Personnel Screening System With a Novel-Shaped Mirror Design
Terahertz systems have attracted much attention recently in the field of public security due to the high penetration of terahertz waves through clothes and the high resolution of terahertz images. A novel real aperture terahertz personnel screening system is demonstrated in this work. This system uses a single transmitter and receiver pair together with a quasi-optical system to irradiate and collect the terahertz waves. In the quasi-optical system, a novel design of a shaped reflector used as the main mirror helps reach a satisfying focus and meanwhile keep the beam direction invariant. By using this main mirror and a hexagonal cylindrical scanning mirror, a fast horizontal scan of 0.6m field of view can be accomplished withing 10 milliseconds. The vertical scan is realized by a customized translation stage. The whole system is able to finish a whole-body scan of a person within 2.9s with a cross-section resolution of less than 8mm.