DVDamien Voilliot
Damien Voilliot
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Damien Voilliot has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Alberto Battaglia
CIC-IT 1433, INSERM, Universite de Lorraine and CHRU Nancy, Nancy France
1 shared publication - Christian de Chillou
Department of Cardiology, University Hospital Nancy , Nancy
1 shared publication - Freddy Odille
IADI U1254, INSERM and Université de Lorraine Nancy France
1 shared publication - Jacques Felblinger
IADI (U1254) Université de Lorraine and Inserm Nancy France
1 shared publication - Jean-Marc Sellal
Department of Cardiology, CHRU Nancy , Nancy
1 shared publication - Philip Hoyland
IADI U1254, Inserm and Université de Lorraine, Nancy, France
1 shared publication
Latest Publications
- 7 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (11) , 3278-3287
Catheter Treatment of Ventricular Tachycardia: A Reference-Less Pace-Mapping Method to Identify Ablation Targets
Objective: A novel method is developed to identify ablation targets for the catheter treatment of ventricular tachycardia (VT). Methods: The method is based on pacemapping, which is a validated technique to determine the catheter ablation targets. Conventionally, it consists of stimulating the heart ventricle from various sites and comparing the resulting activation pathways to that of a clinical VT, by analysis of surface electrocardiograms (ECG). In this work a novel pace-mapping method is presented, that does not require a reference ECG recording of the VT. A 3D correlation gradient map is reconstructed by semi-automatic analysis of ECG morphological changes within the network of pace-mapping sites. In these maps, abnormal points are identified by high correlation gradient values (i.e. corresponding to slow propagation of the electric influx, as in the core of the reentrant VT circuit). The relation between the conventional and reference-less method is described theoretically and evaluated in a retrospective study including 24 VT ablation procedures. Results: The “reference-less” method was able to identify normal points with a high accuracy (negative predictive value: NPV=97%) and to detect more abnormal points, as predicted by the theory. Correlation gradients computed by the proposed method were significantly higher in ablation zones than in other zones of the ventricle $(p < 10^{-12})$ , indicating excellent prediction of the ablation targets. Significance: The reference-less method might either be used in complement of the conventional method, or to treat patients in whom VT cannot be induced during the intervention.- 7 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (11) , 3278-3287
Catheter Treatment of Ventricular Tachycardia: A Reference-Less Pace-Mapping Method to Identify Ablation Targets
Objective: A novel method is developed to identify ablation targets for the catheter treatment of ventricular tachycardia (VT). Methods: The method is based on pacemapping, which is a validated technique to determine the catheter ablation targets. Conventionally, it consists of stimulating the heart ventricle from various sites and comparing the resulting activation pathways to that of a clinical VT, by analysis of surface electrocardiograms (ECG). In this work a novel pace-mapping method is presented, that does not require a reference ECG recording of the VT. A 3D correlation gradient map is reconstructed by semi-automatic analysis of ECG morphological changes within the network of pace-mapping sites. In these maps, abnormal points are identified by high correlation gradient values (i.e. corresponding to slow propagation of the electric influx, as in the core of the reentrant VT circuit). The relation between the conventional and reference-less method is described theoretically and evaluated in a retrospective study including 24 VT ablation procedures. Results: The “reference-less” method was able to identify normal points with a high accuracy (negative predictive value: NPV=97%) and to detect more abnormal points, as predicted by the theory. Correlation gradients computed by the proposed method were significantly higher in ablation zones than in other zones of the ventricle $(p < 10^{-12})$ , indicating excellent prediction of the ablation targets. Significance: The reference-less method might either be used in complement of the conventional method, or to treat patients in whom VT cannot be induced during the intervention.