Yidong Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yidong Zhu has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Kejian Shi
Electric Power Research Institute, State Grid Liaoning Electric Power Co., Ltd., Shenyang 110006, China
3 shared publications - Jiahui Zhu
China Electric Power Research Institute, Beijing, China
2 shared publications - Jie Zhao
School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
2 shared publications - Rui Li
Hubei Engineering and Technology Research Center for AC/DC Intelligent Distribution Network, School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
2 shared publications - Taiyu Gu
Electric Power Research Institute, State Grid Liaoning Electric Power Co., Ltd., Shenyang 110006, China
2 shared publications - Ye Tian
Electric Power Research Institute, State Grid Liaoning Electric Power Co., Ltd., Shenyang 110006, China
2 shared publications
Latest Publications
- Open Access
- 8 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (16) , 3520
Distribution Network Partitioning Method Based on Integrated Electrical Distance and Improved DPC-LPA
Distribution network partitioning at high distributed-energy-resource penetration is challenged by operating-point-insensitive distance criteria, initialization dependence, and oversized or oscillatory zones. This paper presents a framework that combines a comprehensive electrical distance metric with an improved density peak clustering–label propagation algorithm (DPC-LPA). The metric integrates network impedance and voltage sensitivities to renewable-power variations. DPC determines the initial number and centers of zones, and the modified LPA uses partition-scale, load-balance, and historical-influence factors to regulate zone growth and label switching. Tests on medium- and low-voltage alternating-current/direct-current (AC/DC) networks show improved load balance relative to conventional LPA with only a modest change in modularity. These results support the method for the evaluated networks without implying performance beyond the tested conditions.
- 8 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (16) , 3520
Open AccessDistribution Network Partitioning Method Based on Integrated Electrical Distance and Improved DPC-LPA
Distribution network partitioning at high distributed-energy-resource penetration is challenged by operating-point-insensitive distance criteria, initialization dependence, and oversized or oscillatory zones. This paper presents a framework that combines a comprehensive electrical distance metric with an improved density peak clustering–label propagation algorithm (DPC-LPA). The metric integrates network impedance and voltage sensitivities to renewable-power variations. DPC determines the initial number and centers of zones, and the modified LPA uses partition-scale, load-balance, and historical-influence factors to regulate zone growth and label switching. Tests on medium- and low-voltage alternating-current/direct-current (AC/DC) networks show improved load balance relative to conventional LPA with only a modest change in modularity. These results support the method for the evaluated networks without implying performance beyond the tested conditions.
- Open Access
- 14 June 2026
- Published by MDPI AG in Electronics
- Vol. 15 (12) , 2629
Rapid Recovery and Self-Healing Strategies for Power Distribution Systems Based on Dynamic Mesh Networks
With the increasing integration of distributed energy sources, fault restoration in power distribution systems faces challenges in terms of real-time performance and adaptability. To effectively manage the uncertainty and volatility of distributed generation, this paper proposes a rapid self-healing strategy based on a dynamic operational grid. By enabling real-time topological reconfiguration and utilizing adaptive resource allocation, the proposed method accommodates the inherent fluctuations of distributed energy sources. First, a dynamic grid weighted graph theory model is constructed, and an emergency control strategy combining particle preprocessing and stepwise optimization is designed to achieve rapid fault response. Then, a “primary-secondary” two-tier restoration mechanism is established: the primary layer integrates the Floyd algorithm with optimized adaptive dynamic programming to achieve millisecond-level restoration of critical loads; the secondary layer employs an improved particle swarm algorithm incorporating Lévy flight perturbations and adaptive weighting to maximize the restoration of general loads. Simulations on a 56-node system demonstrate that this method achieves 100% restoration of critical loads under various fault scenarios. Even under extreme conditions, it can restore 90.88% of secondary loads and 44.63% of tertiary loads, forming a self-healing system characterized by “second-level detection and minute-level restoration,” thereby significantly enhancing system resilience.
- 14 June 2026
- Published by MDPI AG in Electronics
- Vol. 15 (12) , 2629
Open AccessRapid Recovery and Self-Healing Strategies for Power Distribution Systems Based on Dynamic Mesh Networks
With the increasing integration of distributed energy sources, fault restoration in power distribution systems faces challenges in terms of real-time performance and adaptability. To effectively manage the uncertainty and volatility of distributed generation, this paper proposes a rapid self-healing strategy based on a dynamic operational grid. By enabling real-time topological reconfiguration and utilizing adaptive resource allocation, the proposed method accommodates the inherent fluctuations of distributed energy sources. First, a dynamic grid weighted graph theory model is constructed, and an emergency control strategy combining particle preprocessing and stepwise optimization is designed to achieve rapid fault response. Then, a “primary-secondary” two-tier restoration mechanism is established: the primary layer integrates the Floyd algorithm with optimized adaptive dynamic programming to achieve millisecond-level restoration of critical loads; the secondary layer employs an improved particle swarm algorithm incorporating Lévy flight perturbations and adaptive weighting to maximize the restoration of general loads. Simulations on a 56-node system demonstrate that this method achieves 100% restoration of critical loads under various fault scenarios. Even under extreme conditions, it can restore 90.88% of secondary loads and 44.63% of tertiary loads, forming a self-healing system characterized by “second-level detection and minute-level restoration,” thereby significantly enhancing system resilience.
- Open Access
Intelligent Prediction of Transformer Loss for Low Voltage Recovery in Distribution Network with Unbalanced Load
In order to solve the problem of low voltage caused by unbalanced load in the distribution network, a transformer loss intelligent prediction model under unbalanced load is proposed. Firstly, the mathematical model of a transformer with an unbalanced load is established. The zero-sequence impedance and neutral line current of the transformer are calculated by using the Chaos Game Optimization algorithm (CGO), and the correctness of the mathematical model is proved by using actual data. Then, the correlation among network input variables is eliminated by using Principal Component Analysis (PCA), so the number of network input variables is decreased. At the same time, Sparrow Search Algorithm (SSA) is used to optimize the initial weight and threshold of the BP network, and an accurate transformer loss prediction model based on the PCA-SSA-BP is established. Finally, compared with the transformer loss prediction model based on BP network, Genetic Algorithm optimized BP network (GA-BP), Particle Swarm optimized BP network (PSO-BP) and Sparrow Search Algorithm optimized BP network (SSA-BP), the transformer loss prediction model based on PCA-SSA-BP network has been proven to be accurate by using actual data and it is helpful for low-voltage recovery in the distribution network.
Open AccessIntelligent Prediction of Transformer Loss for Low Voltage Recovery in Distribution Network with Unbalanced Load
In order to solve the problem of low voltage caused by unbalanced load in the distribution network, a transformer loss intelligent prediction model under unbalanced load is proposed. Firstly, the mathematical model of a transformer with an unbalanced load is established. The zero-sequence impedance and neutral line current of the transformer are calculated by using the Chaos Game Optimization algorithm (CGO), and the correctness of the mathematical model is proved by using actual data. Then, the correlation among network input variables is eliminated by using Principal Component Analysis (PCA), so the number of network input variables is decreased. At the same time, Sparrow Search Algorithm (SSA) is used to optimize the initial weight and threshold of the BP network, and an accurate transformer loss prediction model based on the PCA-SSA-BP is established. Finally, compared with the transformer loss prediction model based on BP network, Genetic Algorithm optimized BP network (GA-BP), Particle Swarm optimized BP network (PSO-BP) and Sparrow Search Algorithm optimized BP network (SSA-BP), the transformer loss prediction model based on PCA-SSA-BP network has been proven to be accurate by using actual data and it is helpful for low-voltage recovery in the distribution network.
- 22 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Experimental and Numerical Study on the Magnetization Process of Roebel Cable Segments
ReBCO based HTS cable conductors, due to its large transport current, are crucial for the requirement of large-scale applications such as accelerator magnets, fusion magnets and SMES systems. One key characteristic of these conductors is their electromagnetic response under alternating external magnetic field. Test samples of a 10-strand ReBCO based Roebel cable were studied both experimentally and numerically. Samples were magnetized without transport current at 77 K by ramping up and down the external magnetic field. The remnant fields (screening current field) after the removal of external fields were mapped using a scanning Hall probe with fixed distance (1-5.5 mm) above the sample surface. Corresponding 3D FEM models were developed using T-A formulation with thin strip approximation. The experiment results and simulation solutions showed good agreements, which confirmed the validity of the numerical model, as well as provided us with a better understanding of the magnetization process and remant field characteristics of Roebel cable.
- 22 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Experimental and Numerical Study on the Magnetization Process of Roebel Cable Segments
ReBCO based HTS cable conductors, due to its large transport current, are crucial for the requirement of large-scale applications such as accelerator magnets, fusion magnets and SMES systems. One key characteristic of these conductors is their electromagnetic response under alternating external magnetic field. Test samples of a 10-strand ReBCO based Roebel cable were studied both experimentally and numerically. Samples were magnetized without transport current at 77 K by ramping up and down the external magnetic field. The remnant fields (screening current field) after the removal of external fields were mapped using a scanning Hall probe with fixed distance (1-5.5 mm) above the sample surface. Corresponding 3D FEM models were developed using T-A formulation with thin strip approximation. The experiment results and simulation solutions showed good agreements, which confirmed the validity of the numerical model, as well as provided us with a better understanding of the magnetization process and remant field characteristics of Roebel cable.
- 11 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-4
Design and Evaluation of a Novel Non-Inductive Unit for a High Temperature Superconducting Fault Current Limiter (SFCL) with Bias Magnetic Field
The level of fault current is also enlarged against ca-pacity of conventional circuit break in some urban power grids with the rapid increase of power load. Thus, high temperature su-perconducting fault current limiter (HT SFCL) has been suggested to provide effective and reliable protection of power devices against fault currents. This paper deals with design of a prototype hybrid SFCL which is integrated by a double split reactor with asymmet-ric non-inductively wound copper windings and a non-inductive HTS magnet in series to one branch of the reactor. There is a fast switch in series to the magnet as well. The role of non-inductive magnet is for reducing the fault current in the first swing and the double split reactor decrease the fault current further. The non-inductive HTS unit is designed based on the magneto-thermal cou-pled model. A non-inductive superconducting unit prototype is constructed using YBCO coated conductor and is immersed in the LN2. A high speed Data Acquisition (DAQ) System of National In-struments (NI) based on LABVIEW is built. The critical current and current impact performance for this prototype under the op-erating temperature of 77K are investigated experimentally. The experimental results validate the current limiting effectiveness of the non-inductive unit for the SFCL with bias magnetic field.
- 11 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-4
Design and Evaluation of a Novel Non-Inductive Unit for a High Temperature Superconducting Fault Current Limiter (SFCL) with Bias Magnetic Field
The level of fault current is also enlarged against ca-pacity of conventional circuit break in some urban power grids with the rapid increase of power load. Thus, high temperature su-perconducting fault current limiter (HT SFCL) has been suggested to provide effective and reliable protection of power devices against fault currents. This paper deals with design of a prototype hybrid SFCL which is integrated by a double split reactor with asymmet-ric non-inductively wound copper windings and a non-inductive HTS magnet in series to one branch of the reactor. There is a fast switch in series to the magnet as well. The role of non-inductive magnet is for reducing the fault current in the first swing and the double split reactor decrease the fault current further. The non-inductive HTS unit is designed based on the magneto-thermal cou-pled model. A non-inductive superconducting unit prototype is constructed using YBCO coated conductor and is immersed in the LN2. A high speed Data Acquisition (DAQ) System of National In-struments (NI) based on LABVIEW is built. The critical current and current impact performance for this prototype under the op-erating temperature of 77K are investigated experimentally. The experimental results validate the current limiting effectiveness of the non-inductive unit for the SFCL with bias magnetic field.