    Characterization of Bio composite Boards Fabricated from Pleurotus ostreatus, and Pleurotus australis Incorporated with Spent Sawdust Substrate

    by Oscar Jr. Cabanero Barawid, Mark Angelo Espiritu Diaz, Alking Basamot Gorospe, Jedie Margarette Teh, Kenth Lyndon Ladio, Kelly Lombres, Mary Grace Astejada

    This study investigates the mechanical properties of bio composite boards fabricated from mushroom fruiting bodies of Pleurotus ostreatus (white oyster) and Pleurotus australis (brown oyster) combined with spent sawdust substrate and bonded using a cornstarch-based adhesive. Boards with varying mushroom–substrate ratios were produced and evaluated under uniaxial tensile and three-point bending loads in accordance with ASTM D3039 and ASTM D790 standards. The results demonstrate that board composition strongly influences mechanical property. Single-component boards produced solely from mushroom fruiting bodies or substrate exhibited limited mechanical strength due to low stiffness and weak inter-particle bonding, respectively. In contrast, hybrid formulations showed improved tensile and flexural properties. For both mushroom species, the 86 g mushroom: 54 g substrate formulation produced the highest tensile strength, indicating that tensile property is optimized when shredded mushroom tissues form a continuous organic matrix reinforced by lignocellulosic sawdust particles. Under flexural loading, white oyster boards exhibited their highest strength in substrate-dominant compositions, while brown oyster boards achieved maximum flexural strength at a higher substrate content (54 g mushroom: 86 g substrate). Overall, the findings highlight the potential of mushroom fruiting body–sawdust bio composites as sustainable, low-impact materials for non-load-bearing construction panels, insulation boards, and packaging applications.

  • Open Access

    International round-robin test for electromechanical properties of HTS wires under uniaxial tension at liquid nitrogen temperature

    by Hyung Seop Shin, M A Diaz, Kozo Osamura, Yue Zhao, Yifei Zhang, I Falorio, Nadezda Bagrets, Xing-Yi Zhang, Mark Angelo Espiritu Diaz

    As superconducting wires have become more prevalent, it has become increasingly important to establish reliable and standardized methods for evaluating their electromechanical properties (EMPs) at cryogenic temperatures. An international round-robin test (RRT) was conducted to assess the EMPs of four commercially available high-temperature superconducting (HTS) tapes as an activity to establish a standard for the EMP test method. Six laboratories participated in the RRT, adhering to the guidelines. During tensile testing of the HTS wires at 77 K, critical current (I c) measurements were performed using a stress-based test method. This method streamlined the testing procedure by changing stress intervals from broad to narrow as the applied stress approached the I c degradation point while eliminating the need for dedicated extensometers. The EMPs of the reversible stress limit (R rev) and retention stress limit (R ret) for I c degradation were defined based on specific criteria for 99% I c0 recovery and 95% I c0 retention. Once the RRT participants reported their test results, statistical analysis tools such as ANOVA were employed to identify sources of variation and assess their magnitude in the results. The primary source of the relative standard uncertainty was the effect of inter-laboratory scattering. The RRT results are utilized to develop an international standard for evaluating EMPs of HTS wires through I c measurements under uniaxial tension at liquid nitrogen temperature. These RRT analysis results offer valuable insights into potential sources and magnitudes of measurement uncertainties, ultimately contributing to standardized test procedures for accurate and reliable EMP characterization of HTS wires.


  • Analysis of Cu-Edge on Delamination Strength of Cu-Stabilized REBCO Tapes During Transverse Tension Test Using Anvil Method

    by Michael B. De Leon, Richard Pascua, Mark Angelo Diaz, Gellieca Dullas, Hyung-Seop Shin

    REBCO-coated conductor (CC) tapes in superconducting devices, such as high-field magnets and coils, experience various stresses, including radial transverse tensile stress from Lorentz forces. This stress can cause delamination, compromising the tape's layered structure and potentially leading to device failure. The Cu stabilizer in CC tapes plays a crucial role in maintaining structural integrity by binding constituent layers with different properties, especially addressing the mismatch in the coefficient of thermal expansion. However, the role of Cu layers in resisting delamination remains unclear. In this study, anvil tests under transverse tension and numerical simulations were performed to investigate the delamination strength of REBCO CC tapes with varying Cu stabilizer thicknesses. CC tapes with Cu edges and those where the edge Cu layers were manually removed were compared, revealing the weakest interlayer. Numerical simulations helped understand the impact of Cu-edges on stress distribution during the anvil test. The findings clarify the role of Cu edges in delamination behavior and offer insights to improve the design and fabrication of more durable superconducting devices.


  • Open Access

    A practical stress-based test method for evaluating reversible stress limit for critical current degradation in rare-earth barium copper oxide (REBCO) tapes

    by Hyung-Seop Shin, Madelene Velasco, Mark Angelo Diaz

    The superior electromechanical properties of second-generation high-temperature superconducting rare-earth barium copper oxide (REBCO) coated conductor tapes make them viable candidates for high magnetic field applications. To characterize their electromechanical properties (EMPs) under operating conditions, the critical current degradation behavior of the REBCO tapes should be evaluated. Conventional evaluation methods for EMPs usually rely on a strain-based test method that utilizes an extensometer to measure the deformation induced on the coated conductor tape. This study aims to establish a practical stress-based test method that determines the reversible stress limit for critical current (Ic) degradation in REBCO tapes without using extensometers under uniaxial tension. For an efficient test procedure, Ic measurements were initially performed with broad stress intervals and then changed to narrow stress intervals before the critical current degraded irreversibly. Four commercially available REBCO tape samples were used to validate the reliability of the proposed stress-based test method. It was then assessed by comparing them with those obtained using the conventional strain-based test method. Statistical estimations were used to determine the reproducibility of the results. These results provide a basis for an international round-robin test guideline to establish a test method for measuring the electromechanical properties of high-temperature superconducting tapes at cryogenic temperatures.


  • Widthwise Bending-Induced Response of Critical Current in REBCO Tapes

    by Michael B. de Leon, Arman Ray Nisay, Mark Angelo Diaz, Hyung-Seop Shin

    This study investigates the effect of widthwise bending on the critical current ( I c ) degradation of 2nd generation high-temperature superconducting (RE)Ba 2 Cu 3 O 7−x coated conductor (CC) tapes. The multi-layer stacked geometry of these tapes makes their superconducting properties highly anisotropic to stresses and strains in different directions. To apply these tapes in high-field magnets, coils, and cables, it is essential to understand their electromechanical properties, particularly the stress/strain effect on I c . In this study, limits to the allowed bending-induced deformation and strain along the widthwise direction of the CC tape before permanent I c degradation occurred were investigated. Sample holders were used to measure I c at multiple locations on CC tapes with 12 mm widths subjected to widthwise bending at 77 K and self-field. Results showed that widthwise bending can greatly influence I c degradation behaviors and cause considerable I c drops in the bent sections, particularly under tension bending. Additionally, irreversible permanent tape deformation was observed at smaller bending radii, damaging the superconducting layer under tension bending. Scanning electron microscopy observations of the (RE)Ba 2 Cu 3 O 7−x film after widthwise bending test were used to analyze the tape deformations at multiple locations and the corresponding I c degradations.


  • Characterization of Electromechanical Delamination Behaviors in Practical REBCO Coated Conductor Tapes Under Transverse Tension at 77 K

    by Mark Angelo Diaz, Hyung-Seop Shin

    In high-temperature superconducting coils, the high transport current density and magnetic field generate a large electromagnetic force on REBCO-coated conductor (CC) tapes. A large Lorentz force can cause interlayer delamination damage to the CC tape under radial or transverse tensile loads. The structural delamination characteristics of multilayered REBCO CC tape are essential for the fabrication of mechanically reliable CC coils. In this study, the electromechanical delamination behaviors of practical REBCO CC tapes were characterized using an anvil test method. Our recently established continuous critical current, I c measurement system was used to minimize the test time and can directly evaluate the effect of the transverse tensile load on I c behavior without time-consuming intermittent I c measurements during testing. Characterization of the delamination mechanism, including damage initiation, was performed through scanning electron microscopy observation of the fractured sample. Two-parameter Weibull distribution analysis was used to specify the data scattering of the electromechanical delamination strength.


  • Bending Strain Sensitivity of Critical Current in REBCO Coated Conductor Winding for Coil Application at 77 K

    by M. B. de Leon, A. R. Nisay, M. A. Diaz, H. S. Shin

    High-temperature superconducting (RE)Ba 2 Cu 3 O 7-x (REBCO)-coated conductor (CC) tapes are known for their capacity to tolerate high tensile stress under uniaxial tension, which is typically in the range of 600-700 MPa at 77 K. However, when used in a coil, there is a limit to the allowed strain before degradation of the critical current ( I c ) occurs. This is attributed to the combined strain due to bending and axial tension which was caused during fabrication, cool down, and operation of coils and magnets and corresponds to the irreversible strain limit of I c degradation. Applied strain along the CC tape's edgewise direction (hard bending strain) also affects the irreversible strain limits of I c considerably. With such conditions, degradation of the REBCO coil performance can be expected. Therefore, the current study aims to systematically investigate the mechanism for such I c degradation in REBCO coils. Linear superposition of strains induced in different modes of easy and hard bending were studied analytically and experimentally. The I c degradation behaviors were examined in IBAD/REBCO CC tapes in windings with different pitches on mandrels with different diameters. The investigation was done at 77 K and in self-field conditions using an apparatus designed for coil testing. The bend strain parameters in coils were analyzed, including the radius of curvature and pitch between CC tape turns. Through the linear superposition of strains induced in the REBCO coils, an appropriate approach is suggested to effectively handle the I c degradation under winding including edgewise bending.


  • Evaluation of the Electromechanical Performance of Practical REBCO CC Tapes Under Low Magnetic Fields Using a Continuous Critical Current Measuring System at 77 K

    by Mark Angelo Diaz, Michael De Leon, Hyung-Seop Shin, Byoung-Jean Mean, Jae Hun Lee

    The superior electromechanical properties (EMPs) of REBCO coated conductor (CC) tapes allow their use in a wide range of practical superconducting applications such as coils and magnets; however, the extreme environments degrade the current-carrying capabilities of the tapes. It is therefore important to develop techniques for evaluating their EMPs, to determine their design limits, and to assess the strain/stress dependence of critical current, Ic, in various settings. Moreover, understanding the Ic degradation behaviors of CC tapes under low magnetic fields will provide information helpful for predicting Ic behaviors when the operating conditions include high magnetic fields and low temperatures. Therefore, in this study, the EMPs of three kinds of practical REBCO CC tapes under low magnetic fields were evaluated using our recently developed easy-to-use measuring system that can continuously measure variations in Ic while applying a load or deformation to a CC tape specimen. Through the feedback control of voltage induced across the specimen during loading, we could depict the Ic degradation behaviors of the CC tapes.


  • System for characterizing the electromechanical properties of REBCO coated conductors through simultaneous measurements of critical current and mechanical load

    by Mark Angelo Diaz, Michael De Leon, Hyung-Seop Shin, Byeong-Jin Mean, Jae-Hun Lee

    Various test techniques have been established to investigate the electromechanical properties (EMPs) of coated conductor (CC) tapes under external loads. The most conventional method is to examine variations in a critical current, I c , by repeatedly measuring the V–I curves while intermittently applying a load or deformation to the CC tape. Conventional methods for obtaining EMPs, such as the reversible limits for I c degradation, require repeated measures of I c in a loading–unloading scheme, and this entails considerable time and effort, therefore, they must be improved for practical and engineering reasons. We recently developed an easy-to-use system that can continuously measure variations in I c while applying a load or deformation to the CC tape, thereby evaluating its EMPs. The main advantages of the new measurement system are real-time monitoring of I c behaviors during loading and allowing reduced the test time. While it uses a conventional test configuration, this new system continuously measures I c through effective feedback control of the electrical-field voltage induced in the CC tape specimen during loading. Through this feedback control system, the I c degradation behaviors in CC tapes resulting from possible cracking in the superconducting layer during loading are depicted. The reversible limits for I c degradation were also determined. To assess the effectiveness of this newly developed measuring system, the applicability of the method was identified by evaluating the EMPs of various commercially available CC tapes. By comparing the results with those achieved using conventional testing, we found this to effectively evaluate the EMPs of CC tapes. The results showed that this system provides a simple way of evaluating the EMPs of high-temperature superconductor CC tapes by simultaneously measuring variations in I c under load or deformation. It is much faster at depicting I c degradation behaviors, and it elaborately determines the reversible limits of I c induced in the CC tape during testing.


  • Evaluation of Electromechanical Properties in Multiple HTS Layered Conductors at 77 K

    by Mark Angelo Diaz, Arman Ray Nisay, Hyung-Seop Shin, Gwan-Tae Kim, Sang-Soo Oh, Hong-Soo Ha

    High engineering critical current density (J e ) is demanded in high-performance large-scale applications such as power cables, high-magnetic-field magnets, accelerators, and fusion reactors. In developing high current capacity and low vulnerability under a high magnetic field, high-temperature superconducting (HTS) rare-earth barium copper oxide coated conductors (CCs) have undergone various trials, and CC tape characteristics have ultimately been greatly improved. The Korea Electrotechnology Research Institute recently developed a “multiple HTS layers on one substrate” (MHOS) conductor that can carry high critical current, I c , based on the number of superconducting layers deposited on one substrate. The superconducting layers in a MHOS conductor are much thicker than in a single-layered CC tape, possibly affecting the degradation behaviors of I c under a mechanical load. To ensure the performance and reliability of MHOS conductors, it is necessary to evaluate the strain/stress response of I c . In this study, the electromechanical properties of MHOS conductors were investigated using the uniaxial tension test method as well as the single-sided bending test at 77 K and self-field and at 0.5 T using a pair of neodymium permanent magnets.