G. D. P. Mahidhar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
G. D. P. Mahidhar has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Balaji Srinivasan
Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai, India
1 shared publication - Ramanujam Sarathi
Department of Electrical Engineering Indian Institute of Technology Chennai India
1 shared publication
Latest Publications
- 5 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 4 (2) , 1-4
Fluorescence Fiber Based Identification of Partial Discharges in Liquid Nitrogen for High-Temperature Superconducting Power Apparatus
Partial discharge (PD) in liquid nitrogen insulation is a key issue in cryogenic or high temperature superconducting power apparatus. In this paper, we experimentally demonstrate PD identification in liquid nitrogen using fluorescent optical fiber sensor and compare its sensitivity to the conventional Ultra-High Frequency (UHF) technique. The Corona Inception Voltage (CIV) in LN2 is studied under fundamental AC and harmonic AC voltages with different values of Total Harmonic Distortion (THD). It is observed that CIV reduces with the increase in harmonic voltage with higher Total Harmonic Distortion (THD). Phase resolved partial discharge (PRPD) pattern, peak to peak voltage and the energy content due to corona discharges measured by both fluorescence-based and UHF techniques follows same trend, indicating the viability of the new technique.
- 5 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 4 (2) , 1-4
Fluorescence Fiber Based Identification of Partial Discharges in Liquid Nitrogen for High-Temperature Superconducting Power Apparatus
Partial discharge (PD) in liquid nitrogen insulation is a key issue in cryogenic or high temperature superconducting power apparatus. In this paper, we experimentally demonstrate PD identification in liquid nitrogen using fluorescent optical fiber sensor and compare its sensitivity to the conventional Ultra-High Frequency (UHF) technique. The Corona Inception Voltage (CIV) in LN2 is studied under fundamental AC and harmonic AC voltages with different values of Total Harmonic Distortion (THD). It is observed that CIV reduces with the increase in harmonic voltage with higher Total Harmonic Distortion (THD). Phase resolved partial discharge (PRPD) pattern, peak to peak voltage and the energy content due to corona discharges measured by both fluorescence-based and UHF techniques follows same trend, indicating the viability of the new technique.