WXWanze Xiong

Wanze Xiong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wanze Xiong has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Deming Liu

    Wuhan National Laboratory for Optoelectronics and School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan, China

    1 shared publication
  • Jiangshan Zhang

    School of Electronic Information and Communications, Huazhong University of Science and Technology, wuhan, Hubei China

    1 shared publication
  • Ping Lu

    Wuhan National Laboratory for Optoelectronics (WNLO) and National Engineering Research Center of Next Generation Internet Access System, School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan, China

    1 shared publication
  • Wei Zhang

    National Engineering Laboratory for Next Generation Internet Access System, Huazhong University of Science and Technology School of Optical and Electronic Information, 529011 Wuhan, Hubei China

    1 shared publication
  • Wenjun Ni

    Nanyang Technological University

    1 shared publication

Latest Publications

  • Open Access

    Gold-Diaphragm Based Fabry-Perot Ultrasonic Sensor for Partial Discharge Detection and Localization

    by Wei Zhang, Ping Lu, Wenjun Ni, Wanze Xiong, Deming Liu, Jiangshan Zhang

    Acoustic measurement is the most widely used non-electric method to detect partial discharge (PD) signals by detect the ultrasonic waves arisen from partial discharge. To solve the shortages of low sensitivity and susceptibility to interferences, a gold diaphragm based Fabry-Perot interferometer ultrasonic sensor is proposed and experimentally demonstrated. Its high acoustic sensitivity and directional insensitivity shows great capability for PD detection and localization. Experimental results illustrate a well acoustic response from 20 kHz to 150 kHz when standard ultrasonic signals applied. The frequency range covers the acoustic frequencies derived from PD process. The ultrasonic signals from a discharge source is measured by the proposed fiber optic sensor with difference distances and incident angles. The output shows an attenuation of 1.32 dB/m and the sensor can detect weak signals as far as 3 m. The directional deviation coefficients are less than 10% for each measuring distance which exhibits directional independence. Two localization techniques with a sensor array (four sensors) are proposed and simulations are carried out to verify them feasible. The fiber-optic ultrasonic sensor may have a great potential in stability maintenance of electrical power systems due to its low cost, compact structure, environmentally robustness and simple manufacturing.