Sheng Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sheng Zhao has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Ping Gao
Zhejiang Tengen Electrics Co., Ltd., Yueqing, China
3 shared publications- Zhengjiang Zhang
College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, China
3 shared publications Liang Shu
College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, 325035, People’s Republic of China
2 shared publications- Liang Shu
Wenzhou University
2 shared publications Shiwei Ge
Zhejiang Tengen Electric Co., Ltd
2 shared publicationsChong Chen
The Key Laboratory of Low‐Voltage Apparatus Intellectual Technology of Zhejiang Wenzhou University Wenzhou Zhejiang 325000 China
1 shared publication
Latest Publications
- 28 July 2025
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 20 (6) , 3709-3722
Data Model Compression Method Based on Iterative Pruning and Distillation for Edge Non-Intrusive Load Monitoring
- 28 July 2025
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 20 (6) , 3709-3722
Data Model Compression Method Based on Iterative Pruning and Distillation for Edge Non-Intrusive Load Monitoring
- 12 April 2025
- Published by Springer Nature
- p. 165-174
Adaptive Composite Sliding Filtering-Based Method for NILM Event Detection
- 12 April 2025
- Published by Springer Nature
- p. 165-174
Adaptive Composite Sliding Filtering-Based Method for NILM Event Detection
- 16 January 2025
- Published by IOP Publishing in Engineering Research Express
- Vol. 7 (1) , 015223
HP-MobileNetV3: a lightweight neural network for non-intrusive load monitoring
Non-intrusive load monitoring (NILM) constitutes an extremely promising technology within the realm of intelligent energy management. Its application possesses the potential to accelerate the construction of smart cities and power ecology, encourage consumers to adjust their electricity consumption behavior, and reduce carbon emissions. Despite the fact that recent deep learning neural network models have demonstrated excellent performance in NILM tasks, these models often require a large amount of computation and sufficient hardware memory to handle the electricity parameters from user edge devices as well as ensure the security of communication data. This makes it difficult to use them on edge devices with limited hardware resources. To overcome these limitations, this study proposes a network architecture named HP-MobileNetV3, which significantly reduces the model size and computational requirements through hierarchical pointwise convolution and network structure pruning, enabling its deployment on edge devices. Experimental results, conducted on the publicly available PLAID dataset, demonstrate that HP-MobileNetV3 achieves a reduction of 96.74% in the number of parameters, 83.51% in computational load, and 35.18% in inference time, while maintaining performance, thus facilitating the practical application of NILM technology.
- 16 January 2025
- Published by IOP Publishing in Engineering Research Express
- Vol. 7 (1) , 015223
HP-MobileNetV3: a lightweight neural network for non-intrusive load monitoring
Non-intrusive load monitoring (NILM) constitutes an extremely promising technology within the realm of intelligent energy management. Its application possesses the potential to accelerate the construction of smart cities and power ecology, encourage consumers to adjust their electricity consumption behavior, and reduce carbon emissions. Despite the fact that recent deep learning neural network models have demonstrated excellent performance in NILM tasks, these models often require a large amount of computation and sufficient hardware memory to handle the electricity parameters from user edge devices as well as ensure the security of communication data. This makes it difficult to use them on edge devices with limited hardware resources. To overcome these limitations, this study proposes a network architecture named HP-MobileNetV3, which significantly reduces the model size and computational requirements through hierarchical pointwise convolution and network structure pruning, enabling its deployment on edge devices. Experimental results, conducted on the publicly available PLAID dataset, demonstrate that HP-MobileNetV3 achieves a reduction of 96.74% in the number of parameters, 83.51% in computational load, and 35.18% in inference time, while maintaining performance, thus facilitating the practical application of NILM technology.
- Open Access
- 26 June 2023
- Published by MDPI AG in Electronics
- Vol. 12 (13) , 2824
Non-Intrusive Load Monitoring Based on the Combination of Gate-Transformer and CNN
Non-intrusive load monitoring (NILM) is the practice of estimating power consumption of a single household appliance using data from a total power meter of the user’s house. The transformer model has emerged as a popular method for handling NILM problems. However, with the increase in data from electricity meters, there is a need for research focusing on the accuracy and computational complexity of the transformer model. To address this, this paper proposes a sequence-to-sequence load decomposition structure named GTCN, which combines the gate-transformer and convolutional neural networks (CNNs). GTCN introduces a gating mechanism to reduce the number of parameters for training the model while maintaining performance. The introduction of CNNs can effectively capture local features that the gate-transformer may not be able to capture, thereby improving the accuracy of power estimation of individual household appliances. The results of the experiments, based on the UK-DALE dataset, illustrate that GTCN not only demonstrates excellent decomposition performance but also reduces the model parameters compared to conventional transformers. Moreover, the proposed GTCN structure, despite maintaining the same number of model parameters as the traditional transformer architecture after incorporating CNNs, outperforms the conventional transformer model, as well as current seq2seq and R-LSTM technologies, and achieves enhanced prediction accuracy and improved generalization capability.
- 26 June 2023
- Published by MDPI AG in Electronics
- Vol. 12 (13) , 2824
Open AccessNon-Intrusive Load Monitoring Based on the Combination of Gate-Transformer and CNN
Non-intrusive load monitoring (NILM) is the practice of estimating power consumption of a single household appliance using data from a total power meter of the user’s house. The transformer model has emerged as a popular method for handling NILM problems. However, with the increase in data from electricity meters, there is a need for research focusing on the accuracy and computational complexity of the transformer model. To address this, this paper proposes a sequence-to-sequence load decomposition structure named GTCN, which combines the gate-transformer and convolutional neural networks (CNNs). GTCN introduces a gating mechanism to reduce the number of parameters for training the model while maintaining performance. The introduction of CNNs can effectively capture local features that the gate-transformer may not be able to capture, thereby improving the accuracy of power estimation of individual household appliances. The results of the experiments, based on the UK-DALE dataset, illustrate that GTCN not only demonstrates excellent decomposition performance but also reduces the model parameters compared to conventional transformers. Moreover, the proposed GTCN structure, despite maintaining the same number of model parameters as the traditional transformer architecture after incorporating CNNs, outperforms the conventional transformer model, as well as current seq2seq and R-LSTM technologies, and achieves enhanced prediction accuracy and improved generalization capability.
- 21 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (6) , 5314-5324
Design and Adaptive Control of Matrix Transformer Based Indirect Converter for Large-Capacity Circuit Breaker Testing Application
Circuit breakers (CBs) have played important roles in the power distribution network. According to IEC standards, the protection characteristics need to be investigated in the manufacturing process to ensure high reliability. It is required from IEC 60947 that the instantaneous release shall be verified with a test current at least 10 times of the rated current. For large-capacity CB testing, converters with large output current, high accuracy and fast response are needed. A large current indirect converter including four converting units and a matrix transformer is proposed. The converting units are synchronized using a CPLD based logic control unit. To increase the current accuracy, an adaptive feedforward control strategy is developed to compensate the influences of CB-dependent resistances and inductances. The equivalent load impedance is adaptively identified from a robust identifier, which is then used to construct the feedforward compensator. Simulation and experimental results show that different circuit breakers bring in CB-dependent contact resistances and inductances in the testing circuit. The impedance change can be successfully identified by the robust identifier with limited errors. The proposed converter is capable of generating a wide range of current from 100 A to 40 kA with the error no more than 2.2%.
- 21 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (6) , 5314-5324
Design and Adaptive Control of Matrix Transformer Based Indirect Converter for Large-Capacity Circuit Breaker Testing Application
Circuit breakers (CBs) have played important roles in the power distribution network. According to IEC standards, the protection characteristics need to be investigated in the manufacturing process to ensure high reliability. It is required from IEC 60947 that the instantaneous release shall be verified with a test current at least 10 times of the rated current. For large-capacity CB testing, converters with large output current, high accuracy and fast response are needed. A large current indirect converter including four converting units and a matrix transformer is proposed. The converting units are synchronized using a CPLD based logic control unit. To increase the current accuracy, an adaptive feedforward control strategy is developed to compensate the influences of CB-dependent resistances and inductances. The equivalent load impedance is adaptively identified from a robust identifier, which is then used to construct the feedforward compensator. Simulation and experimental results show that different circuit breakers bring in CB-dependent contact resistances and inductances in the testing circuit. The impedance change can be successfully identified by the robust identifier with limited errors. The proposed converter is capable of generating a wide range of current from 100 A to 40 kA with the error no more than 2.2%.
- 11 February 2020
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 15 (5) , 714-722
Dynamic Data Reconciliation to Decrease the Effect of Measurement Noise on Controller Performance Assessment
Controller performance assessment (CPA) is capable to evaluate the controller performance and has been widely used in industrial processes. In the existing research studies, CPA usually assumes that the feedback signals are the actual process outputs without considering the measurement noise. Minimum variance (MV)‐based CPA is the most common method for controller performance evaluation. In this paper, the effect of measurement noise is considered in the feedback signals of the MV‐based CPA. The dynamic data reconciliation (DDR) is incorporated in the MV‐based CPA (DDR‐MV‐CPA) to decrease the effect of measurement noise on CPA. The effectiveness of the proposed DDR‐MV‐CPA method is demonstrated via theoretical derivation, simulations, and experimental comparisons. © 2020 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
- 11 February 2020
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 15 (5) , 714-722
Dynamic Data Reconciliation to Decrease the Effect of Measurement Noise on Controller Performance Assessment
Controller performance assessment (CPA) is capable to evaluate the controller performance and has been widely used in industrial processes. In the existing research studies, CPA usually assumes that the feedback signals are the actual process outputs without considering the measurement noise. Minimum variance (MV)‐based CPA is the most common method for controller performance evaluation. In this paper, the effect of measurement noise is considered in the feedback signals of the MV‐based CPA. The dynamic data reconciliation (DDR) is incorporated in the MV‐based CPA (DDR‐MV‐CPA) to decrease the effect of measurement noise on CPA. The effectiveness of the proposed DDR‐MV‐CPA method is demonstrated via theoretical derivation, simulations, and experimental comparisons. © 2020 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
- Open Access
- 10 January 2020
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 14 (2) , 157-164
Optimal design and control of a new permanent magnet AC contactor with forced breaking mechanism
This study addresses the design of a new type of permanent magnet contactor, which uses forced breaking to overcome failure conditions. A multi‐objective optimisation method based on the genetic algorithm is used to design the contactor considering the effects of average closing time, average breaking time, impact energy, Joule heat and contactor volume. Four prototypes have been fabricated according to the optimised parameters. A control circuit is developed to increase breaking reliability. The circuit is designed as two separate modules: a normal working module and a protection module. The former is used during the normal contactor operation and the latter is used for forced breaking protection. Breaking failures are detected by comparing the time delay between the breaking control voltage and the auxiliary contact voltage. A durability experiment has been conducted to verify the protection function of the proposed PM contactor. Experimental results show that the normal working module fails to break the contactor in the last testing cycle. However, under the actuation of the protection mechanism, the contactor is forced to break and the power circuit can be successfully switched off.
- 10 January 2020
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 14 (2) , 157-164
Open AccessOptimal design and control of a new permanent magnet AC contactor with forced breaking mechanism
This study addresses the design of a new type of permanent magnet contactor, which uses forced breaking to overcome failure conditions. A multi‐objective optimisation method based on the genetic algorithm is used to design the contactor considering the effects of average closing time, average breaking time, impact energy, Joule heat and contactor volume. Four prototypes have been fabricated according to the optimised parameters. A control circuit is developed to increase breaking reliability. The circuit is designed as two separate modules: a normal working module and a protection module. The former is used during the normal contactor operation and the latter is used for forced breaking protection. Breaking failures are detected by comparing the time delay between the breaking control voltage and the auxiliary contact voltage. A durability experiment has been conducted to verify the protection function of the proposed PM contactor. Experimental results show that the normal working module fails to break the contactor in the last testing cycle. However, under the actuation of the protection mechanism, the contactor is forced to break and the power circuit can be successfully switched off.