Gang Chen
Gang Chen has a total of 113 co-authors. Here are the top co-authors by number of shared publications:
- Huabo Shi
State Grid Sichuan Electric Power Research Institute, Chengdu 610041, China
12 shared publications - Pengyu Pan
State Grid Sichuan Electric Power Research Institute, Chengdu, China
7 shared publications - Xueyang Zeng
State Grid Sichuan Electrical Power Research Institute, Chengdu 610041, China
7 shared publications - Lijie Ding
State Grid Sichuan Electric Power Research Institute, Chengdu 610041, China
5 shared publications - Yufei Teng
State Grid Sichuan Electric Power Research Institute, Chengdu, China
5 shared publications - Xiaoming Zha
Wuhan University
4 shared publications
Latest Publications
- Open Access
Analysis of Power Regulation Characteristics for Pumped Storage Plants Containing a Variable-Speed Unit with a Full-Size Converter and a Fixed-Speed Unit Considering Hydraulic Disturbances Under Turbine Mode
The rapid and frequent power regulation of variable-speed pumped storage units with a full-size converter (VSPSU with FSC) causes strong hydraulic disturbances in fixed-speed units (FSU) within shared pipelines. The influence of power command rates on the system has not been sufficiently quantified. Therefore, a model of pumped storage plant (PSP) containing VSPSU with FSC and FSU is constructed and validated against internationally used software SIMSEN. Influences of rates on dynamic characteristics are analyzed under turbine power reduction condition. An evaluation method is proposed to quantify power regulation performance for selecting optimal rates. Results indicate the following: (1) Advantage: the VSPSU-FSU demonstrates a superior power response compared to FSU-FSU under fast power control strategy. (2) Influence: overshoots of parameters show positive correlations with rates, while regulation time generally exhibits negative correlations. (3) Evaluation: Power regulation performance has a non-monotonic relationship with rates of VSPSU. Considering rapidity, safety, and stability comprehensively, the performance initially raises to a peak and then declines. Under 50% power reduction, the optimal power command rate is 0.1 p.u./s. The VSPSU–FSU active power regulation time is 4.9 s, significantly lower compared to FSU–FSU (45.17 s). This paper offers crucial insights for optimizing operation of PSPs with VSPSU and FSU.
Open AccessAnalysis of Power Regulation Characteristics for Pumped Storage Plants Containing a Variable-Speed Unit with a Full-Size Converter and a Fixed-Speed Unit Considering Hydraulic Disturbances Under Turbine Mode
The rapid and frequent power regulation of variable-speed pumped storage units with a full-size converter (VSPSU with FSC) causes strong hydraulic disturbances in fixed-speed units (FSU) within shared pipelines. The influence of power command rates on the system has not been sufficiently quantified. Therefore, a model of pumped storage plant (PSP) containing VSPSU with FSC and FSU is constructed and validated against internationally used software SIMSEN. Influences of rates on dynamic characteristics are analyzed under turbine power reduction condition. An evaluation method is proposed to quantify power regulation performance for selecting optimal rates. Results indicate the following: (1) Advantage: the VSPSU-FSU demonstrates a superior power response compared to FSU-FSU under fast power control strategy. (2) Influence: overshoots of parameters show positive correlations with rates, while regulation time generally exhibits negative correlations. (3) Evaluation: Power regulation performance has a non-monotonic relationship with rates of VSPSU. Considering rapidity, safety, and stability comprehensively, the performance initially raises to a peak and then declines. Under 50% power reduction, the optimal power command rate is 0.1 p.u./s. The VSPSU–FSU active power regulation time is 4.9 s, significantly lower compared to FSU–FSU (45.17 s). This paper offers crucial insights for optimizing operation of PSPs with VSPSU and FSU.
- Open Access
- 1 January 2026
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2026 (1)
A Novel Suppression Strategy for the Reverse Regulation Phenomenon of Variable Speed Pumped Storage Unit With Full‐Size Converter
Wind power, photovoltaic, and other new clean energy generations exhibit large power fluctuations and strong intermittency, whose rapid integration leads to grid frequency instability and even major blackouts. Energy storage systems are thus urgently required to improve the grid’s flexible regulation capability. The variable speed pumped storage unit with full‐size converter (FSC‐VSPSU) can provide large‐capacity, fast, and flexible regulation resources, making it increasingly widely applied. However, during its rapid regulation, the significant time‐scale difference between the converter controller and turbine governor causes a reverse regulation phenomenon, which seriously endangers unit safety. To address this problem, this study first clarifies the specific mechanism of reverse regulation using energy flow diagrams. A novel suppression method based on DC‐side energy storage is then proposed, which is innovative in targeted solving the time‐scale mismatch‐induced reverse regulation issue of FSC‐VSPSU. Finally, a simulation model is established in MATLAB/SIMULINK to verify the reverse regulation mechanism and the effectiveness of the proposed strategy. The simulation results demonstrate that the proposed method can effectively suppress the reverse regulation phenomenon, significantly improving the operational safety and stability of FSC‐VSPSU. This study provides a new technical approach for the stable operation of FSC‐VSPSU in grid flexible regulation.
- 1 January 2026
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2026 (1)
Open AccessA Novel Suppression Strategy for the Reverse Regulation Phenomenon of Variable Speed Pumped Storage Unit With Full‐Size Converter
Wind power, photovoltaic, and other new clean energy generations exhibit large power fluctuations and strong intermittency, whose rapid integration leads to grid frequency instability and even major blackouts. Energy storage systems are thus urgently required to improve the grid’s flexible regulation capability. The variable speed pumped storage unit with full‐size converter (FSC‐VSPSU) can provide large‐capacity, fast, and flexible regulation resources, making it increasingly widely applied. However, during its rapid regulation, the significant time‐scale difference between the converter controller and turbine governor causes a reverse regulation phenomenon, which seriously endangers unit safety. To address this problem, this study first clarifies the specific mechanism of reverse regulation using energy flow diagrams. A novel suppression method based on DC‐side energy storage is then proposed, which is innovative in targeted solving the time‐scale mismatch‐induced reverse regulation issue of FSC‐VSPSU. Finally, a simulation model is established in MATLAB/SIMULINK to verify the reverse regulation mechanism and the effectiveness of the proposed strategy. The simulation results demonstrate that the proposed method can effectively suppress the reverse regulation phenomenon, significantly improving the operational safety and stability of FSC‐VSPSU. This study provides a new technical approach for the stable operation of FSC‐VSPSU in grid flexible regulation.
- Open Access
- 12 December 2025
- Published by MDPI AG in Electronics
- Vol. 14 (24) , 4887
Hybrid N-BEATS-Based Method for Equipment Assessment and System Risk Prediction in Urban Power Grids
To improve power system risk prediction under complex and extreme operating conditions, a hybrid N-BEATS-based framework is proposed for equipment assessment and loss of load expectation (LOLE) forecasting. The method integrates thermal circuit modeling, online thermal parameter identification via physics-informed neural networks (PINNs), Arrhenius–Weibull temperature–failure mapping, Monte Carlo system risk evaluation, and a hybrid spatiotemporal predictor combining N-BEATS and graph neural networks. Case studies on distribution transformers demonstrate improved thermal parameter identification and reduced LOLE forecasting error compared with benchmark methods. The remainder of the paper is organized as follows: Firstly, it presents thermal modeling and PINN identification; Secondly, it introduces the aging-failure and reliability evaluation; Thirdly, it describes the hybrid forecasting framework; Fourthly, it reports case studies; and finally, it concludes.
- 12 December 2025
- Published by MDPI AG in Electronics
- Vol. 14 (24) , 4887
Open AccessHybrid N-BEATS-Based Method for Equipment Assessment and System Risk Prediction in Urban Power Grids
To improve power system risk prediction under complex and extreme operating conditions, a hybrid N-BEATS-based framework is proposed for equipment assessment and loss of load expectation (LOLE) forecasting. The method integrates thermal circuit modeling, online thermal parameter identification via physics-informed neural networks (PINNs), Arrhenius–Weibull temperature–failure mapping, Monte Carlo system risk evaluation, and a hybrid spatiotemporal predictor combining N-BEATS and graph neural networks. Case studies on distribution transformers demonstrate improved thermal parameter identification and reduced LOLE forecasting error compared with benchmark methods. The remainder of the paper is organized as follows: Firstly, it presents thermal modeling and PINN identification; Secondly, it introduces the aging-failure and reliability evaluation; Thirdly, it describes the hybrid forecasting framework; Fourthly, it reports case studies; and finally, it concludes.
- Open Access
Damping Tuning Considering Random Disturbances Adopting Distributionally Robust Optimization
In scenarios where high penetration of renewable energy sources (RES) is connected to the grid over long distances, the output of RES exhibits significant fluctuations, making it difficult to accurately characterize. The intermittency and uncertainty of these fluctuations pose challenges to the stability of the power system. This paper proposes a distributionally robust damping optimization control framework (DRDOC) to address the uncertainty in the true distribution of random disturbances caused by RES. First, the installation location of damping controllers and key control parameters are determined through Sobol sensitivity indices and participation factors. Next, a nonlinear relationship between damping and random disturbances is established with Polynomial Chaos Expansion (PCE). The uncertainty in the distribution of disturbances is captured by ambiguity sets. The DRDOC is formulated as a convex optimization problem, which is further simplified for efficient computation. Finally, the optimal control parameters are derived through convex optimization techniques. Simulation results demonstrate the effectiveness and distribution robustness of the proposed DRDOC.
Open AccessDamping Tuning Considering Random Disturbances Adopting Distributionally Robust Optimization
In scenarios where high penetration of renewable energy sources (RES) is connected to the grid over long distances, the output of RES exhibits significant fluctuations, making it difficult to accurately characterize. The intermittency and uncertainty of these fluctuations pose challenges to the stability of the power system. This paper proposes a distributionally robust damping optimization control framework (DRDOC) to address the uncertainty in the true distribution of random disturbances caused by RES. First, the installation location of damping controllers and key control parameters are determined through Sobol sensitivity indices and participation factors. Next, a nonlinear relationship between damping and random disturbances is established with Polynomial Chaos Expansion (PCE). The uncertainty in the distribution of disturbances is captured by ambiguity sets. The DRDOC is formulated as a convex optimization problem, which is further simplified for efficient computation. Finally, the optimal control parameters are derived through convex optimization techniques. Simulation results demonstrate the effectiveness and distribution robustness of the proposed DRDOC.
- Open Access
- 28 November 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (23) , 11122
Multi-Time Scale Optimal Dispatch of Distribution Network with Pumped Storage Station Based on Model Predictive Control
As the penetration of renewable energy increases, the distribution grid faces great challenges in integrating large amounts of distributed energy sources and dealing with their output uncertainty. To address this, a multi-time scale optimal dispatch method based on model predictive control is proposed, including a day-ahead stage and an intra-day rolling stage. In the day-ahead stage, to fully utilize the flexibility of variable speed pumped storage hydropower, the generating/pumping phase modulation condition is considered, not just generating or pumping. Day-ahead optimal dispatch is established with the objective of minimizing the operation economy and node voltage deviation of the distribution network. In the intra-day rolling stage, model predictive control with finite time domain rolling optimal dispatch is used to replace the traditional single-time section optimal dispatch, considering the forecast data of wind, photovoltaic (PV), and load within the finite time domain, so that can respond in advance to smooth the generator output. At the same time, the uncertainty problem of the distribution network is solved effectively by rolling optimization and feedback correction of model predictive control. In order to consider the daily operating capacity balance of energy storage in the intra-day stage, the capacity imbalance penalty is added to the intra-day rolling optimization objective function, so that the energy storage capacity tries to track the results of the day-ahead optimization, achieving the long-term development of energy storage. Simulation analysis proves the feasibility and effectiveness of the proposed method. The proposed method enhances the generation–load–storage coordinated dispatching ability, effectively improving the distribution network’s capability to respond to fluctuations of renewable energy.
- 28 November 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (23) , 11122
Open AccessMulti-Time Scale Optimal Dispatch of Distribution Network with Pumped Storage Station Based on Model Predictive Control
As the penetration of renewable energy increases, the distribution grid faces great challenges in integrating large amounts of distributed energy sources and dealing with their output uncertainty. To address this, a multi-time scale optimal dispatch method based on model predictive control is proposed, including a day-ahead stage and an intra-day rolling stage. In the day-ahead stage, to fully utilize the flexibility of variable speed pumped storage hydropower, the generating/pumping phase modulation condition is considered, not just generating or pumping. Day-ahead optimal dispatch is established with the objective of minimizing the operation economy and node voltage deviation of the distribution network. In the intra-day rolling stage, model predictive control with finite time domain rolling optimal dispatch is used to replace the traditional single-time section optimal dispatch, considering the forecast data of wind, photovoltaic (PV), and load within the finite time domain, so that can respond in advance to smooth the generator output. At the same time, the uncertainty problem of the distribution network is solved effectively by rolling optimization and feedback correction of model predictive control. In order to consider the daily operating capacity balance of energy storage in the intra-day stage, the capacity imbalance penalty is added to the intra-day rolling optimization objective function, so that the energy storage capacity tries to track the results of the day-ahead optimization, achieving the long-term development of energy storage. Simulation analysis proves the feasibility and effectiveness of the proposed method. The proposed method enhances the generation–load–storage coordinated dispatching ability, effectively improving the distribution network’s capability to respond to fluctuations of renewable energy.
- Open Access
- 12 November 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (22) , 10398
Oscillation Mechanism and Suppression of Variable-Speed Pumped Storage Unit with Full-Size Converter Based on the Measured Single-Input and Single-Output Impedances
As the penetration rate of clean energy gradually increases, the demand for flexible regulation resources in the power grid is increasing accordingly. The variable-speed pumped storage unit with a full-size converter (FSC-VSPSU) can provide fast and flexible regulation resources for the power grid, which assists in the stable operation of the clean-energy-dominated power systems. Thus, its application is gradually becoming widespread. FSC-VSPSU relies on the power electronic converter for grid connection. When the impedance mismatch between FSC-VSPSU and the power grid occurs, the grid-connected system will experience oscillations, which seriously threatens its safe and stable operation. Aiming at this, this article firstly relies on the SISO impedance measurement and an equivalent impedance analysis to obtain the stability analysis criterion. Furthermore, applying the impedance matching analysis with the Bode diagram, the influence rules of the parameters of the grid-connected FSC-VSPSU on oscillation are obtained. In addition, with the summarized oscillation analysis results, this study delves into an exploration of pertinent strategies for oscillation suppression. Finally, a grid-connected FSC-VSPSU simulation model is built in MATLAB/SIMULINK, and the simulation results verify the correctness of the oscillation analysis results and the effectiveness of the proposed oscillation suppression strategy.
- 12 November 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (22) , 10398
Open AccessOscillation Mechanism and Suppression of Variable-Speed Pumped Storage Unit with Full-Size Converter Based on the Measured Single-Input and Single-Output Impedances
As the penetration rate of clean energy gradually increases, the demand for flexible regulation resources in the power grid is increasing accordingly. The variable-speed pumped storage unit with a full-size converter (FSC-VSPSU) can provide fast and flexible regulation resources for the power grid, which assists in the stable operation of the clean-energy-dominated power systems. Thus, its application is gradually becoming widespread. FSC-VSPSU relies on the power electronic converter for grid connection. When the impedance mismatch between FSC-VSPSU and the power grid occurs, the grid-connected system will experience oscillations, which seriously threatens its safe and stable operation. Aiming at this, this article firstly relies on the SISO impedance measurement and an equivalent impedance analysis to obtain the stability analysis criterion. Furthermore, applying the impedance matching analysis with the Bode diagram, the influence rules of the parameters of the grid-connected FSC-VSPSU on oscillation are obtained. In addition, with the summarized oscillation analysis results, this study delves into an exploration of pertinent strategies for oscillation suppression. Finally, a grid-connected FSC-VSPSU simulation model is built in MATLAB/SIMULINK, and the simulation results verify the correctness of the oscillation analysis results and the effectiveness of the proposed oscillation suppression strategy.
- Open Access
- 26 September 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (19) , 8672
Fault Ride-Through Control Strategy for Variable Speed Pumped Storage Unit with Full-Size Converter
Fault ride-through is a prerequisite for ensuring continuous operation of a variable-speed pumped storage unit with a full-size converter (FSC-VSPU) and providing support for the renewable energy and power grid. This paper proposes low-voltage ride through (LVRT) and high-voltage ride through (HVRT) strategies for FSC-VSPU to address this issue. Firstly, the structure of FSC-VSPU and its control strategy under power generation and pumping conditions are described. Subsequently, the fault characteristics of the FSC-VSPU under different operating conditions are analyzed. More stringent fault ride-through technical requirements than those for wind turbines are proposed. On this basis, the fault ride-through strategies of combining fast power drop, rotor energy storage control, power anti-regulation control, dynamic reactive current control, low power protection, and DC crowbar circuit are proposed. Simulation case studies conducted in PSCAD/EMTDC verify the correctness of the theoretical analysis and the effectiveness of the LVRT and HVRT strategies in this paper.
- 26 September 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (19) , 8672
Open AccessFault Ride-Through Control Strategy for Variable Speed Pumped Storage Unit with Full-Size Converter
Fault ride-through is a prerequisite for ensuring continuous operation of a variable-speed pumped storage unit with a full-size converter (FSC-VSPU) and providing support for the renewable energy and power grid. This paper proposes low-voltage ride through (LVRT) and high-voltage ride through (HVRT) strategies for FSC-VSPU to address this issue. Firstly, the structure of FSC-VSPU and its control strategy under power generation and pumping conditions are described. Subsequently, the fault characteristics of the FSC-VSPU under different operating conditions are analyzed. More stringent fault ride-through technical requirements than those for wind turbines are proposed. On this basis, the fault ride-through strategies of combining fast power drop, rotor energy storage control, power anti-regulation control, dynamic reactive current control, low power protection, and DC crowbar circuit are proposed. Simulation case studies conducted in PSCAD/EMTDC verify the correctness of the theoretical analysis and the effectiveness of the LVRT and HVRT strategies in this paper.
- Open Access
- 4 September 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (17) , 7841
Improved Subsynchronous Oscillation Parameter Identification Based on Eigensystem Realization Algorithm
Subsynchronous oscillation (SSO) is the resonance between a new energy generator set and a weak power grid, and the resonance frequency is usually the sub-/super-synchronous frequency. The eigensystem realization algorithm (ERA) is a classic algorithm for extracting modal parameters based on matrix decomposition. By leveraging the ERA’s simplicity and low computational cost, an enhanced methodology for identifying the key parameters of SSO is introduced. The enhanced algorithm realizes SSO angular frequency extraction by constructing an angular frequency fitting equation, enabling efficient identification of SSO parameters using only a 200 ms synchrophasor sequence. In the process of identification, the fitting-based ERA effectively addresses the limitation of the existing ERA. The accuracy of SSO parameter identification is improved, thereby realizing that SSO parameter identification can be carried out using a 200 ms data window. The fitting-based ERA is verified using synthetic and actual data from synchrophasor measurement terminals. The research results show that the proposed algorithm can accurately extract fundamental and subsynchronous or supersynchronous oscillation parameters, effectively realizing dynamic real-time monitoring of subsynchronous oscillations.
- 4 September 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (17) , 7841
Open AccessImproved Subsynchronous Oscillation Parameter Identification Based on Eigensystem Realization Algorithm
Subsynchronous oscillation (SSO) is the resonance between a new energy generator set and a weak power grid, and the resonance frequency is usually the sub-/super-synchronous frequency. The eigensystem realization algorithm (ERA) is a classic algorithm for extracting modal parameters based on matrix decomposition. By leveraging the ERA’s simplicity and low computational cost, an enhanced methodology for identifying the key parameters of SSO is introduced. The enhanced algorithm realizes SSO angular frequency extraction by constructing an angular frequency fitting equation, enabling efficient identification of SSO parameters using only a 200 ms synchrophasor sequence. In the process of identification, the fitting-based ERA effectively addresses the limitation of the existing ERA. The accuracy of SSO parameter identification is improved, thereby realizing that SSO parameter identification can be carried out using a 200 ms data window. The fitting-based ERA is verified using synthetic and actual data from synchrophasor measurement terminals. The research results show that the proposed algorithm can accurately extract fundamental and subsynchronous or supersynchronous oscillation parameters, effectively realizing dynamic real-time monitoring of subsynchronous oscillations.
- Open Access
- 21 August 2024
- Published by MDPI AG in Electronics
- Vol. 13 (16) , 3317
Distributed Robust Optimization Method for Active Distribution Network with Variable-Speed Pumped Storage
Variable-speed pumped storage has the advantages of flexible adjustment and low economic cost, which can reduce the adverse effects caused by a high proportion of new energy access. In order to reduce the system operation risk caused by the randomness of new energy output, a distribution robust optimization method for an active distribution network with variable-speed pumped storage is proposed. Firstly, considering the probability distribution uncertainty of wind–solar prediction error, a two-stage distributed robust optimization model of an active distribution network is constructed with the sum of day-ahead operating cost, intra-day adjustment cost expectation and conditional value-at-risk as the objective function. Then, the probability distribution fuzzy set is constructed based on the norm distance, and the fuzzy set boundary is determined by a data-driven method. Finally, the model is transformed into a mixed integer second-order cone optimization model by a linearization method and duality theory, and verified by an example. The results show that the proposed model can effectively reduce the operation risk caused by the uncertainty of operating cost and wind–solar output and reduce the operational costs and the risks associated with uncertainty in wind and solar power output.
- 21 August 2024
- Published by MDPI AG in Electronics
- Vol. 13 (16) , 3317
Open AccessDistributed Robust Optimization Method for Active Distribution Network with Variable-Speed Pumped Storage
Variable-speed pumped storage has the advantages of flexible adjustment and low economic cost, which can reduce the adverse effects caused by a high proportion of new energy access. In order to reduce the system operation risk caused by the randomness of new energy output, a distribution robust optimization method for an active distribution network with variable-speed pumped storage is proposed. Firstly, considering the probability distribution uncertainty of wind–solar prediction error, a two-stage distributed robust optimization model of an active distribution network is constructed with the sum of day-ahead operating cost, intra-day adjustment cost expectation and conditional value-at-risk as the objective function. Then, the probability distribution fuzzy set is constructed based on the norm distance, and the fuzzy set boundary is determined by a data-driven method. Finally, the model is transformed into a mixed integer second-order cone optimization model by a linearization method and duality theory, and verified by an example. The results show that the proposed model can effectively reduce the operation risk caused by the uncertainty of operating cost and wind–solar output and reduce the operational costs and the risks associated with uncertainty in wind and solar power output.