Wei Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wei Shi has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Fei Ji
Senior Department of Otolaryngology Head and Neck Surgery 6th Medical Center Chinese PLA General Hospital Beijing China
2 shared publications Hai-Na Ding
Department of Otolaryngology Head and Neck Surgery, Chinese PLA General Hospital, Beijing, China
2 shared publications- Qiuju Wang
Department of Audiology and Vestibular Medicine, Senior Department of Otolaryngology, Head and Neck Surgery Chinese PLA Institute of Otolaryngology, The Sixth Medical Center of Chinese PLA General Hospital Beijing China
2 shared publications Bo Zhong
Mechanics and Acoustics Division, National Institute of Metrology, Beijing, China
1 shared publication- Fen Xiong
Department of Audiology and Vestibular Medicine, Senior Department of Otolaryngology, Head and Neck Surgery Chinese PLA General Hospital, Medical School of Chinese PLA Beijing China
1 shared publication - Hongyang Wang
Senior Department of Otolaryngology Head and Neck Surgery, the 6th Medical Center of Chinese PLA General Hospital Chinese PLA Medical School, 6 Fucheng Road, Beijing, 100048, PR China; State Key Laboratory of Hearing and Balance Science, 28 Fuxing Road, Beijing 100853, PR China; National Clinical Research Center for Otolaryngologic Diseases, 28 Fuxing Road, Beijing 100853, PR China
1 shared publication
Latest Publications
- 21 April 2023
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 63 (6) , 467-471
Noise effective masking level for bone conduction of wide-spectrum short-duration signals in normal hearing adults
The objective of this study is to determine the noise effective masking level (EML) and inter-aural attenuation (IA) for click and CE-Chirp signals presented though a Radioear B-81 to elicit the au...
- 21 April 2023
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 63 (6) , 467-471
Noise effective masking level for bone conduction of wide-spectrum short-duration signals in normal hearing adults
The objective of this study is to determine the noise effective masking level (EML) and inter-aural attenuation (IA) for click and CE-Chirp signals presented though a Radioear B-81 to elicit the au...
- Open Access
- 24 November 2022
- Published by Wiley in Laryngoscope Investigative Otolaryngology
- Vol. 7 (6) , 2095-2102
The audiological characteristics of infant auditory neuropathy patients without otoacoustic emission
Objective: To explore the audiological characteristics of infant auditory neuropathy (AN) patients with cochlear microphonic (CM) recorded but absent otoacoustic emission (OAE), clinically reducing the rate of missed diagnosis of AN.Methods: We retrospectively analyzed the audiological characteristics of infant AN patients in our medical center between 2003 and 2020. A total of 18 infant AN patients were OAE absent group, with CM present and distortion product otoacoustic emission (DPOAE) absent in both ears. A total of 44 infant AN patients were OAE present group, with CM and DPOAE present in both ears.Results: (1) The found age in OAE absent group was 0.9 (0.02) years old, which was younger than 1.11 (1.63) years old in OAE present group (p = .041). (2) The CM threshold of OAE absent group was 80 (10) dB nHL, which was significantly higher (p < .001) than OAE present group. CM amplitude were smaller (p < .05), and CM duration were shorter (p < .05) in OAE absent group. (3) The thresholds of auditory steady‐state response (ASSR) at 0.5, 1, 2, and 4 kHz were 94 (10), 94 (10), 87 (20), and 81 (10) dB HL cg, respectively in OAE absent group, which were higher than those in OAE present group (p < .01).Conclusions: Infant AN patients with CM present and OAE absent showed earlier detection and different audiological performance, which was manifested in ASSR thresholds, audiometric configurations and CM performance. CM thresholds were increased, amplitude and duration were decreased, non‐linearity of I/O function was reduced.Level of Evidence: 4
- 24 November 2022
- Published by Wiley in Laryngoscope Investigative Otolaryngology
- Vol. 7 (6) , 2095-2102
Open AccessThe audiological characteristics of infant auditory neuropathy patients without otoacoustic emission
Objective: To explore the audiological characteristics of infant auditory neuropathy (AN) patients with cochlear microphonic (CM) recorded but absent otoacoustic emission (OAE), clinically reducing the rate of missed diagnosis of AN.Methods: We retrospectively analyzed the audiological characteristics of infant AN patients in our medical center between 2003 and 2020. A total of 18 infant AN patients were OAE absent group, with CM present and distortion product otoacoustic emission (DPOAE) absent in both ears. A total of 44 infant AN patients were OAE present group, with CM and DPOAE present in both ears.Results: (1) The found age in OAE absent group was 0.9 (0.02) years old, which was younger than 1.11 (1.63) years old in OAE present group (p = .041). (2) The CM threshold of OAE absent group was 80 (10) dB nHL, which was significantly higher (p < .001) than OAE present group. CM amplitude were smaller (p < .05), and CM duration were shorter (p < .05) in OAE absent group. (3) The thresholds of auditory steady‐state response (ASSR) at 0.5, 1, 2, and 4 kHz were 94 (10), 94 (10), 87 (20), and 81 (10) dB HL cg, respectively in OAE absent group, which were higher than those in OAE present group (p < .01).Conclusions: Infant AN patients with CM present and OAE absent showed earlier detection and different audiological performance, which was manifested in ASSR thresholds, audiometric configurations and CM performance. CM thresholds were increased, amplitude and duration were decreased, non‐linearity of I/O function was reduced.Level of Evidence: 4
- 6 November 2011
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 132 (2) , 188-196
Characteristics of cochlear microphonics in infants and young children with auditory neuropathy
Conclusions: Cochlear microphonics (CMs) play an important role in the diagnosis of auditory neuropathy (AN). It is necessary and helpful to diagnose the sites-of-lesion in infants and children with AN by analyzing the patterns of CM amplitudes and I/O functions together. Objectives: To investigate the characteristics and clinical significance of CMs in the diagnosis of AN among infants and children. Methods: A total of 36 infants and children (16 males and 20 females) were divided into two groups. Group A included 15 children (30 ears) with auditory brainstem response (ABR) absent and distortion product otoacoustic emissions (DPOAEs) present and group B included 21 children (30 ears) with ABR absent and DPOAEs absent. Fifteen normal-hearing infants (30 ears) made up the control group. Click eliciting CMs were recorded at stimulus levels of 100, 90, 80, and 70 dB nHL for each ear using a button electrode placed at the top of the forehead. A tube-clamping method was used to distinguish CMs from artifacts, and an averaging algorithm was used to obtain a clear CM waveform. The time delay and amplitude of CMs were measured in both children with AN and normal-hearing infants on (C–R)/2 waveforms, and an I/O function curve for each group was plotted with the stimulating level as input and the CM amplitude as output. Results: The largest identifiable CMs were generally found between 0.5 and 0.8 ms after stimulation with mean delay of 0.63 ± 0.04 ms in both group A and the control group, and 0.63 ± 0.07 ms in group B. There was no significant difference between the AN group and the control group in CM time delay. There was no significant difference (p > 0.05) between group A (AN with OAEs present, 0.47 ± 0.15 μV) and the control group (0.45 ± 0.13 μV) in CM amplitude, while CM amplitudes in children with AN with DPOAEs absent (0.24 ± 0.08 μV) were significantly lower than those in either the control group or group A (p < 0.01). The amplitude of CMs reduced with stimulus intensity in all the subjects. There was obvious nonlinearity in group A and the control group, while there was a more linear tendency in amplitude increasing on the I/O function curve in group B.
- 6 November 2011
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 132 (2) , 188-196
Characteristics of cochlear microphonics in infants and young children with auditory neuropathy
Conclusions: Cochlear microphonics (CMs) play an important role in the diagnosis of auditory neuropathy (AN). It is necessary and helpful to diagnose the sites-of-lesion in infants and children with AN by analyzing the patterns of CM amplitudes and I/O functions together. Objectives: To investigate the characteristics and clinical significance of CMs in the diagnosis of AN among infants and children. Methods: A total of 36 infants and children (16 males and 20 females) were divided into two groups. Group A included 15 children (30 ears) with auditory brainstem response (ABR) absent and distortion product otoacoustic emissions (DPOAEs) present and group B included 21 children (30 ears) with ABR absent and DPOAEs absent. Fifteen normal-hearing infants (30 ears) made up the control group. Click eliciting CMs were recorded at stimulus levels of 100, 90, 80, and 70 dB nHL for each ear using a button electrode placed at the top of the forehead. A tube-clamping method was used to distinguish CMs from artifacts, and an averaging algorithm was used to obtain a clear CM waveform. The time delay and amplitude of CMs were measured in both children with AN and normal-hearing infants on (C–R)/2 waveforms, and an I/O function curve for each group was plotted with the stimulating level as input and the CM amplitude as output. Results: The largest identifiable CMs were generally found between 0.5 and 0.8 ms after stimulation with mean delay of 0.63 ± 0.04 ms in both group A and the control group, and 0.63 ± 0.07 ms in group B. There was no significant difference between the AN group and the control group in CM time delay. There was no significant difference (p > 0.05) between group A (AN with OAEs present, 0.47 ± 0.15 μV) and the control group (0.45 ± 0.13 μV) in CM amplitude, while CM amplitudes in children with AN with DPOAEs absent (0.24 ± 0.08 μV) were significantly lower than those in either the control group or group A (p < 0.01). The amplitude of CMs reduced with stimulus intensity in all the subjects. There was obvious nonlinearity in group A and the control group, while there was a more linear tendency in amplitude increasing on the I/O function curve in group B.