Marcel Ohera
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marcel Ohera has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Lubomír Gryc
2 shared publicationsMartina Nováková
2 shared publications- Anna Selivanova
National Radiation Protection Institute (SÚRO) , Bartoškova 1450/28, 140 00 Prague , Czechia
1 shared publication Daniel Sas
NBC Defence Institute, University of Defence, Vyškov, Czech Republic
1 shared publication- Daniel Sas
Military University
1 shared publication Irena Češpirová
1 shared publication
Latest Publications
- Open Access
- 14 August 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 59 (1)
Evaluation of aerial monitoring data by extended stripping window method
- 14 August 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 59 (1)
Open AccessEvaluation of aerial monitoring data by extended stripping window method
- 16 April 2024
- Published by Elsevier in Radiation Measurements
- Vol. 174
Application of unmanned aerial vehicles in emergency radiation monitoring
- 16 April 2024
- Published by Elsevier in Radiation Measurements
- Vol. 174
Application of unmanned aerial vehicles in emergency radiation monitoring
- Open Access
- 17 August 2023
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 55 (11) , 4039-4047
Airborne HPGe spectrometer for monitoring of air dose rates and surface activities
- 17 August 2023
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 55 (11) , 4039-4047
Open AccessAirborne HPGe spectrometer for monitoring of air dose rates and surface activities
- Open Access
- 1 December 2022
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 55 (3) , 1052-1060
Full spectrum estimation of helicopter background and cosmic gamma-ray contribution for airborne measurements
- 1 December 2022
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 55 (3) , 1052-1060
Open AccessFull spectrum estimation of helicopter background and cosmic gamma-ray contribution for airborne measurements
- Open Access
- 1 January 2020
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 35 (4) , 323-330
Calibration of spectrometric detectors for air kerma rates in environmental monitoring
The spectrometric systems, especially based on NaI(Tl) and HPGe detectors, are used for nuclide identification and calculation of their activities from the ground measurements and air-borne monitoring. The determination of the air kerma (dose) rates is also very important for environmental measurements. In such cases, the detectors should be calibrated for air kerma (dose) rates in nGyh?1 or ?Gyh?1. A simple calibration of NaI(Tl), HPGe as well as plastic detectors for the low-level air kerma rates is presented in this contribution. This calibration is based on comparing the relative absorbed energy rate in detectors (MeVs?1) calculated from spectra with the air kerma rates calculated by the Monte Carlo simulation and supplementary to the data from the RSS Reuter&Stokes high pressure ion chamber. This method also eliminates the conversion from the non-air kerma rates in crystals to the air kerma rates. Three different types of small cylindrical detectors were calibrated for the air kerma rates from the background of 26 nGyh?1 to some tens of ?Gyh?1 in the energy range to the maximum of 3 MeV. The results of calibrations of the 3" x 3" NaI(Tl), HPGe detector and a small plastic detector (made of polystyrene) including soxme examples of environmental measurements are presented.
- 1 January 2020
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 35 (4) , 323-330
Open AccessCalibration of spectrometric detectors for air kerma rates in environmental monitoring
The spectrometric systems, especially based on NaI(Tl) and HPGe detectors, are used for nuclide identification and calculation of their activities from the ground measurements and air-borne monitoring. The determination of the air kerma (dose) rates is also very important for environmental measurements. In such cases, the detectors should be calibrated for air kerma (dose) rates in nGyh?1 or ?Gyh?1. A simple calibration of NaI(Tl), HPGe as well as plastic detectors for the low-level air kerma rates is presented in this contribution. This calibration is based on comparing the relative absorbed energy rate in detectors (MeVs?1) calculated from spectra with the air kerma rates calculated by the Monte Carlo simulation and supplementary to the data from the RSS Reuter&Stokes high pressure ion chamber. This method also eliminates the conversion from the non-air kerma rates in crystals to the air kerma rates. Three different types of small cylindrical detectors were calibrated for the air kerma rates from the background of 26 nGyh?1 to some tens of ?Gyh?1 in the energy range to the maximum of 3 MeV. The results of calibrations of the 3" x 3" NaI(Tl), HPGe detector and a small plastic detector (made of polystyrene) including soxme examples of environmental measurements are presented.