Fabrice Micoud
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Fabrice Micoud has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Sebastien Rosini
Univ. Grenoble Alpes, CEA, LITEN, Grenoble, France
3 shared publications - Timothée Drugeot
Univ. Grenoble Alpes, CEA, LITEN, Grenoble, France
3 shared publications - Arnaud Morin
Univ Grenoble Alpes, CEA LITEN, F-38000, Grenoble, France
2 shared publications Eric Pinton
2 shared publications- Raphaël Riasse
Univ. Grenoble Alpes, CEA, LITEN, Grenoble, France
2 shared publications - Sylvie Escribano
University Grenoble Alpes, F-38000 Grenoble, France
2 shared publications
Latest Publications
- 30 July 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (15) , 154501
Analysis of MEA Properties Evolution During Break-in in PEMFC
This study evaluates break-in protocols for Pt/Vulcan-XC-72 cathode-based membrane electrode assemblies in PEMFCs. Fast, high-current protocols, lasting under 20 min at low voltage, were compared to a conventional 7-hour constant current procedure. The rapid protocols yielded to higher initial performance and saved up to 91.5% for hydrogen consumption. To elucidate governing mechanisms during break-in, electrochemical analyses were performed. Paradoxically, performance improved despite a modest decrease in electrochemical surface area, notably, voltage cycling induced a 16% specific surface loss, versus 5% for holding. While high-frequency resistance decreased by 16%–19% due to fast membrane hydration, its impact on performance remained modest. Instead, catalyst layer effective protonic resistance ( R eff, H+, CL ) emerged as the dominant factor governing performance, attributed to the reduction of proton transport limitation. Fast protocols yielded significant R eff, H+, CL reductions up to 38%, respectively, whereas the long protocol showed no significant change. These gains correlate with an increase in PtOx coulometry reduction charge and refined CO stripping peak shifted to lower potential, consistent with slight particle growth. These findings indicate that break-in is primarily a hydration-driven restructuring of the catalyst/ionomer interface rather than simple surface cleaning. These mechanisms-based understanding validates rapid protocols for industrial use.
- 30 July 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (15) , 154501
Analysis of MEA Properties Evolution During Break-in in PEMFC
This study evaluates break-in protocols for Pt/Vulcan-XC-72 cathode-based membrane electrode assemblies in PEMFCs. Fast, high-current protocols, lasting under 20 min at low voltage, were compared to a conventional 7-hour constant current procedure. The rapid protocols yielded to higher initial performance and saved up to 91.5% for hydrogen consumption. To elucidate governing mechanisms during break-in, electrochemical analyses were performed. Paradoxically, performance improved despite a modest decrease in electrochemical surface area, notably, voltage cycling induced a 16% specific surface loss, versus 5% for holding. While high-frequency resistance decreased by 16%–19% due to fast membrane hydration, its impact on performance remained modest. Instead, catalyst layer effective protonic resistance ( R eff, H+, CL ) emerged as the dominant factor governing performance, attributed to the reduction of proton transport limitation. Fast protocols yielded significant R eff, H+, CL reductions up to 38%, respectively, whereas the long protocol showed no significant change. These gains correlate with an increase in PtOx coulometry reduction charge and refined CO stripping peak shifted to lower potential, consistent with slight particle growth. These findings indicate that break-in is primarily a hydration-driven restructuring of the catalyst/ionomer interface rather than simple surface cleaning. These mechanisms-based understanding validates rapid protocols for industrial use.
- Open Access
- 4 February 2026
- Published by Springer Nature in Journal of Applied Electrochemistry
- Vol. 56 (3) , 59
Performing cyclic voltammetry in a proton exchange membrane fuel cell stack: accessing local electrode properties using current density mapping
- 4 February 2026
- Published by Springer Nature in Journal of Applied Electrochemistry
- Vol. 56 (3) , 59
Open AccessPerforming cyclic voltammetry in a proton exchange membrane fuel cell stack: accessing local electrode properties using current density mapping
- Open Access
- 1 February 2026
- Published by Springer Nature in Journal of Applied Electrochemistry
- Vol. 56 (3) , 47
Performing cyclic voltammetry in a proton exchange membrane fuel cell stack: what you should keep in mind
Cyclic voltammetry (CV) is a very commonly used technique for the study of electrochemical interfaces. Its application to proton exchange membrane fuel cell (PEMFC) is of great interest as it is sensitive to change in the catalyst layer and membrane state-of-life. Using cyclic voltammograms, it is possible to easily obtain information on the catalyst roughness factor and the hydrogen cross-over current. This study focuses on the best way to perform CV on individual cells at the stack level. To prevent the whole stack polarisation, eight different connection configurations have been tested to obtain comparable CV as the reference case with current applied on the whole stack. The comparison between the cyclic voltammograms and potentiostatic electrochemical impedance spectroscopy (PEIS) for all these configurations lead to some recommendations for bipolar plates design. Contact resistances and proximity of current and potential connections are the main hindrances to the measurement of reliable CV. The authors advise to maximise as much as possible the number of connection pins and to place them on both sides of the PEMFC bipolar plates. If it is not possible on current design, the authors recommend the use of dynamic ohmic drop compensation to minimise the error regarding the determination of roughness factor. Graphical abstract
- 1 February 2026
- Published by Springer Nature in Journal of Applied Electrochemistry
- Vol. 56 (3) , 47
Open AccessPerforming cyclic voltammetry in a proton exchange membrane fuel cell stack: what you should keep in mind
Cyclic voltammetry (CV) is a very commonly used technique for the study of electrochemical interfaces. Its application to proton exchange membrane fuel cell (PEMFC) is of great interest as it is sensitive to change in the catalyst layer and membrane state-of-life. Using cyclic voltammograms, it is possible to easily obtain information on the catalyst roughness factor and the hydrogen cross-over current. This study focuses on the best way to perform CV on individual cells at the stack level. To prevent the whole stack polarisation, eight different connection configurations have been tested to obtain comparable CV as the reference case with current applied on the whole stack. The comparison between the cyclic voltammograms and potentiostatic electrochemical impedance spectroscopy (PEIS) for all these configurations lead to some recommendations for bipolar plates design. Contact resistances and proximity of current and potential connections are the main hindrances to the measurement of reliable CV. The authors advise to maximise as much as possible the number of connection pins and to place them on both sides of the PEMFC bipolar plates. If it is not possible on current design, the authors recommend the use of dynamic ohmic drop compensation to minimise the error regarding the determination of roughness factor. Graphical abstract
- 11 September 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 87, 838-847
Cathode catalyst layer aging of proton exchange membrane fuel cell during emulated start-up/shut-down phases
- 11 September 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 87, 838-847
Cathode catalyst layer aging of proton exchange membrane fuel cell during emulated start-up/shut-down phases
- 1 December 2022
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 48 (14) , 5630-5642
Experimental assessment of proton exchange membrane fuel cell performance degradations during emulated start-up/shut-down phases
- 1 December 2022
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 48 (14) , 5630-5642
Experimental assessment of proton exchange membrane fuel cell performance degradations during emulated start-up/shut-down phases
- 1 September 2019
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2019-02 (33) , 1466
Analysis of PEMFC Stack Components Degradation at Multiple Scales: Impact of the Ageing Modes on the Local Losses
Proton Exchange Membrane Fuel Cell (PEMFC) technologies are considered as a promising and clean energy supply for both transportation and stationary applications. State of art components present performance enabling integration of stacks in actual systems and vehicles. However, durability still needs to be improved as well as overall system cost still needs to be reduced to enable large scale competitive deployment. To this end, extensive investigations are required and conducted to improve understanding of the degradation mechanisms. The work presented is dedicated to the degradation phenomena occurring on MEA components at stack level, taking into account the interactions between the overall and local ageing conditions, respectively induced by the ageing mode and the design, and the local losses. The intention is to support the development of accelerated stress tests for automotive application to be validated on single cells and later-on on specific stack designs in the frame of a dedicated European project [1]. Performance and MEAs degradation are considered to identify causes and mechanisms for both reversible and non-reversible losses. Our main focus is to clarify interactions between global and local conditions as well as between performance losses and components degradation. The approach is applied on aged samples after their ageing in stacks following different load profiles. Pre-ageing, during ageing and post-ageing characterizations of MEA are performed at multiple scales considering in-situ averaged performance and electrochemical properties, in-situ distribution of local conditions such as current density, temperature and water when available, ex-situ local electrochemical properties and components microstructure. Among ageing modes considered in our studies, post-mortem data are available for MEA components after ageing in stacks following long term ageing on test bench, with fixed load steps or adapted drive cycles, or after use in a vehicle as range extender; for comparison, tests are performed with same stack design (active area 220 cm²), similar components and operating conditions. At stack scale, full understanding requires to add local measurements for correlating performance degradation and cell design. Two methods are applied and as far as possible combined to get these local data: current density distribution maps are performed using a segmented cell implemented in the middle of the stacks and post-mortem analyses are conducted on aged samples selected from specific zones (near gases inlet or outlets, middle) of stack-size aged MEAs, by electrochemical measurements in small differential single cells and by advanced electron microscopy techniques, then compared to non-aged samples. Local analyses are conducted so as to identify known mechanisms depending on the zones such as mainly carbon corrosion, platinum or cobalt dissolution and induced ionomer contamination. Results show differences in local effects when applying different ageing modes and the correlation between local conditions related to the design, alterations in the electrodes and performance losses. The image illustrates the multiple-scales characterization approach with a full stack, one 220 cm² MEAs used for post-mortem analyses, one 2 cm² MEA as tested in the small differential cell for electrochemical post-ageing measurements and examples of cyclic voltammograms and SEM/TEM images obtained on local samples from selected zones. [1] Acknowledgements - This work is mainly conducted in the frame of the project ID-FAST. This project has received funding from the Fuel Cells and Hydrogen 2 Joint Undertaking under the European Union’s Horizon 2020 research and innovation program under grant agreement No. 779565. Figure 1
- 1 September 2019
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2019-02 (33) , 1466
Analysis of PEMFC Stack Components Degradation at Multiple Scales: Impact of the Ageing Modes on the Local Losses
Proton Exchange Membrane Fuel Cell (PEMFC) technologies are considered as a promising and clean energy supply for both transportation and stationary applications. State of art components present performance enabling integration of stacks in actual systems and vehicles. However, durability still needs to be improved as well as overall system cost still needs to be reduced to enable large scale competitive deployment. To this end, extensive investigations are required and conducted to improve understanding of the degradation mechanisms. The work presented is dedicated to the degradation phenomena occurring on MEA components at stack level, taking into account the interactions between the overall and local ageing conditions, respectively induced by the ageing mode and the design, and the local losses. The intention is to support the development of accelerated stress tests for automotive application to be validated on single cells and later-on on specific stack designs in the frame of a dedicated European project [1]. Performance and MEAs degradation are considered to identify causes and mechanisms for both reversible and non-reversible losses. Our main focus is to clarify interactions between global and local conditions as well as between performance losses and components degradation. The approach is applied on aged samples after their ageing in stacks following different load profiles. Pre-ageing, during ageing and post-ageing characterizations of MEA are performed at multiple scales considering in-situ averaged performance and electrochemical properties, in-situ distribution of local conditions such as current density, temperature and water when available, ex-situ local electrochemical properties and components microstructure. Among ageing modes considered in our studies, post-mortem data are available for MEA components after ageing in stacks following long term ageing on test bench, with fixed load steps or adapted drive cycles, or after use in a vehicle as range extender; for comparison, tests are performed with same stack design (active area 220 cm²), similar components and operating conditions. At stack scale, full understanding requires to add local measurements for correlating performance degradation and cell design. Two methods are applied and as far as possible combined to get these local data: current density distribution maps are performed using a segmented cell implemented in the middle of the stacks and post-mortem analyses are conducted on aged samples selected from specific zones (near gases inlet or outlets, middle) of stack-size aged MEAs, by electrochemical measurements in small differential single cells and by advanced electron microscopy techniques, then compared to non-aged samples. Local analyses are conducted so as to identify known mechanisms depending on the zones such as mainly carbon corrosion, platinum or cobalt dissolution and induced ionomer contamination. Results show differences in local effects when applying different ageing modes and the correlation between local conditions related to the design, alterations in the electrodes and performance losses. The image illustrates the multiple-scales characterization approach with a full stack, one 220 cm² MEAs used for post-mortem analyses, one 2 cm² MEA as tested in the small differential cell for electrochemical post-ageing measurements and examples of cyclic voltammograms and SEM/TEM images obtained on local samples from selected zones. [1] Acknowledgements - This work is mainly conducted in the frame of the project ID-FAST. This project has received funding from the Fuel Cells and Hydrogen 2 Joint Undertaking under the European Union’s Horizon 2020 research and innovation program under grant agreement No. 779565. Figure 1
- 1 September 2019
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2019-02 (32) , 1415
(Invited) Small Angle Scattering As Unique Probe to Quantify Water Distribution and Ionomer Structure in Operating PEMFC
The Proton Exchange Membrane Fuel Cell (PEMFC) is a highly complex energy conversion device coupling several electrochemical and transport phenomena occurring on a wide range of length-scales within a multilayered structure, named Membrane Electrodes Assembly (MEA). The fundamental description of all phenomena involved in PEMFC operation and degradation, and more particularly their interplay, is a contemplated pivotal requirement for improvements. This is a grand challenge, as a number of unsolved questions remain. In fact, all relevant physical and electrochemical phenomena are not fully identified or quantified. In the PEMFC, water plays a crucial role, since it is not only the main product of the electrochemical reaction but, above all, it is the fundamental common denominator to all the phenomena. In a real stack, as an open system converting H2 and O2, the operation and degradation are intrinsically heterogeneous resulting especially in a complex 3D distribution of water in the volume of the MEA. Among the most important component of the MEA is the ionomer, made of a PerFluoroSulfonic Acid (PFSA) polymer, which acts as a solid electrolyte to transfer proton and water to, from, and within the electrodes. The presence of highly hydrophilic sulfonic acid groups makes it, most probably, the most sensitive MEA component toward water activity/content. Indeed, it governs its swelling, structure as well as transport and mechanical properties. This property of the ionomer, along with its role, explains why PEMFC behaviour is so dependent on water activity. Still very recently, a work of Kongkanand et al.[1] emphasizes how ionomer is a crucial electrodes' constituent in view of enhancing performance. For these reasons, many researches are still devoted to studying the ionomer in relation with water activity and as well as to quantifying the 3D water distribution during PEMFC operation. It is well known that Small Angle Scattering (SAS) is the most suitable technique to characterize the structure of the ionomer[2]. A side from that, neutron is the probe of choice to quantify water within operating PEMFC[3]. For these reasons, we have been developing for several years SAS techniques, either with Neutrons or X-Ray, in order to measure simultaneously and operando, the water distribution and the ionomer nanostructure. Spatial and time resolutions offew µm² and 50 ms, respectively, have been achieved with the last generation of X-Rays sources such as the one of European Synchrotron Radiation Facility (ESRF), and ~4 mm² and 30 s with high neutron flux on D22 beamline at Laue Langevin Institute (ILL)[4],[5]. Thus, it is possible to follow the kinetics during transient. In particular, we have shown that, within the membrane, local water content is greater in front of the current collecting rib than in front of the gas supply channel. We have also evidenced some evolution of the physical structure of the membrane upon aging in real conditions depending on the local water content. We thus pushed forward these techniques, which now allows us to have unique information on the local water activity and ionomer structure within the CL. Our results demonstrate how SAS techniques are powerful to assess the main current scientific and technological issues of the PEMFC. [1] Kongkanand et al., ACS Energy Lett. 2018, 3, 618−621 [2] Fumagalli et al., J. Phys. Chem. B 2015, 119, 7068−7076 [3] Boillat et al., Current Opinion in Electrochemistry 2017, 5, 3–10 [4] Morin et al., J. Electrochem. Soc. 2016, 163, F9-F21 [5] Martinez et al., ACS Advanced Energy Materials 2019 Figure 1
- 1 September 2019
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2019-02 (32) , 1415
(Invited) Small Angle Scattering As Unique Probe to Quantify Water Distribution and Ionomer Structure in Operating PEMFC
The Proton Exchange Membrane Fuel Cell (PEMFC) is a highly complex energy conversion device coupling several electrochemical and transport phenomena occurring on a wide range of length-scales within a multilayered structure, named Membrane Electrodes Assembly (MEA). The fundamental description of all phenomena involved in PEMFC operation and degradation, and more particularly their interplay, is a contemplated pivotal requirement for improvements. This is a grand challenge, as a number of unsolved questions remain. In fact, all relevant physical and electrochemical phenomena are not fully identified or quantified. In the PEMFC, water plays a crucial role, since it is not only the main product of the electrochemical reaction but, above all, it is the fundamental common denominator to all the phenomena. In a real stack, as an open system converting H2 and O2, the operation and degradation are intrinsically heterogeneous resulting especially in a complex 3D distribution of water in the volume of the MEA. Among the most important component of the MEA is the ionomer, made of a PerFluoroSulfonic Acid (PFSA) polymer, which acts as a solid electrolyte to transfer proton and water to, from, and within the electrodes. The presence of highly hydrophilic sulfonic acid groups makes it, most probably, the most sensitive MEA component toward water activity/content. Indeed, it governs its swelling, structure as well as transport and mechanical properties. This property of the ionomer, along with its role, explains why PEMFC behaviour is so dependent on water activity. Still very recently, a work of Kongkanand et al.[1] emphasizes how ionomer is a crucial electrodes' constituent in view of enhancing performance. For these reasons, many researches are still devoted to studying the ionomer in relation with water activity and as well as to quantifying the 3D water distribution during PEMFC operation. It is well known that Small Angle Scattering (SAS) is the most suitable technique to characterize the structure of the ionomer[2]. A side from that, neutron is the probe of choice to quantify water within operating PEMFC[3]. For these reasons, we have been developing for several years SAS techniques, either with Neutrons or X-Ray, in order to measure simultaneously and operando, the water distribution and the ionomer nanostructure. Spatial and time resolutions offew µm² and 50 ms, respectively, have been achieved with the last generation of X-Rays sources such as the one of European Synchrotron Radiation Facility (ESRF), and ~4 mm² and 30 s with high neutron flux on D22 beamline at Laue Langevin Institute (ILL)[4],[5]. Thus, it is possible to follow the kinetics during transient. In particular, we have shown that, within the membrane, local water content is greater in front of the current collecting rib than in front of the gas supply channel. We have also evidenced some evolution of the physical structure of the membrane upon aging in real conditions depending on the local water content. We thus pushed forward these techniques, which now allows us to have unique information on the local water activity and ionomer structure within the CL. Our results demonstrate how SAS techniques are powerful to assess the main current scientific and technological issues of the PEMFC. [1] Kongkanand et al., ACS Energy Lett. 2018, 3, 618−621 [2] Fumagalli et al., J. Phys. Chem. B 2015, 119, 7068−7076 [3] Boillat et al., Current Opinion in Electrochemistry 2017, 5, 3–10 [4] Morin et al., J. Electrochem. Soc. 2016, 163, F9-F21 [5] Martinez et al., ACS Advanced Energy Materials 2019 Figure 1