Xiaonan Guan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiaonan Guan has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Yanlin Ge
Institute of Thermal Science and Power Engineering, Wuhan Institute of Technology, Wuhan 430205, China
2 shared publications - Zhihui Xie
College of Power Engineering, Naval University of Engineering, Wuhan 430033, China
2 shared publications - Zhuoqun Lu
College of Power Engineering, Naval University of Engineering, Wuhan 430033, China
2 shared publications - Gang Nan
College of Power Engineering, Naval University of Engineering, Wuhan 430033, China
1 shared publication - Jian Zhang
School of Power Engineering, Naval University of Engineering, Wuhan 430033, China
1 shared publication - Jiechang Wu
College of Power Engineering, Naval University of Engineering, Wuhan 430030, China
1 shared publication
Latest Publications
- Open Access
- 20 December 2023
- Published by MDPI AG in Micromachines
- Vol. 15 (1) , 9
Suitability of Embedded Liquid Cooling and Heat Generation for Chips
Embedded liquid cooling is a preferred solution for dissipating the heat generated by high-power chips. The cooling capacity and pump power consumption of embedded liquid cooling heat sinks differ significantly between different structures. To achieve an accurate match between cooling capacity and heat dissipation requirements, the selection of a liquid-cooled heat sink should be carefully considered in conjunction with the heat dissipation needs of heat sources in real-world thermal management issues. Based on the manufacturing limitations on chip temperature and microchannel pressure, a composite performance index function was developed to assess the cooling capacity and cooling cost of the heat sink. This allowed for the establishment of an evaluation standard to determine the suitability of embedded liquid cooling and heat sink for the heat source. In this study, the suitability of four microchannel heat sinks with the same feature length and fin volume was evaluated under various thermal load conditions. The results show that the best-suited heat sink changes with variations in the thermal load of the chip. In the example, when the heat source was homogeneous at 100 W, the circular section pin fins have an optimal suitability of 0.928 for Re = 500. When the heat source was a heterogeneous heat source with a power of 100 W, the value of Θ was found to be 0.389. Additionally, the optimal suitability of drop section pin fins for Re = 971.5 was determined to be 0.862.
- 20 December 2023
- Published by MDPI AG in Micromachines
- Vol. 15 (1) , 9
Open AccessSuitability of Embedded Liquid Cooling and Heat Generation for Chips
Embedded liquid cooling is a preferred solution for dissipating the heat generated by high-power chips. The cooling capacity and pump power consumption of embedded liquid cooling heat sinks differ significantly between different structures. To achieve an accurate match between cooling capacity and heat dissipation requirements, the selection of a liquid-cooled heat sink should be carefully considered in conjunction with the heat dissipation needs of heat sources in real-world thermal management issues. Based on the manufacturing limitations on chip temperature and microchannel pressure, a composite performance index function was developed to assess the cooling capacity and cooling cost of the heat sink. This allowed for the establishment of an evaluation standard to determine the suitability of embedded liquid cooling and heat sink for the heat source. In this study, the suitability of four microchannel heat sinks with the same feature length and fin volume was evaluated under various thermal load conditions. The results show that the best-suited heat sink changes with variations in the thermal load of the chip. In the example, when the heat source was homogeneous at 100 W, the circular section pin fins have an optimal suitability of 0.928 for Re = 500. When the heat source was a heterogeneous heat source with a power of 100 W, the value of Θ was found to be 0.389. Additionally, the optimal suitability of drop section pin fins for Re = 971.5 was determined to be 0.862.
- Open Access
- 2 December 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (12) , 2136
Thermal–Hydrodynamic Behavior and Design of a Microchannel Pin-Fin Hybrid Heat Sink
A three-dimensional convective heat transfer model of a microchannel pin-fin hybrid heat sink was established. Considering the non-uniform heat generation of 3D stacked chips, the splitting distance of pin-fins was optimized by minimizing the maximum heat sink temperature under different heat fluxes in the hotspot, the Reynolds numbers at the entrance of the microchannel, and the proportions of the pin-fin volume. The average pressure drop and the performance evaluation criteria were considered to be the performance indexes to analyze the influence of each parameter on the flow performance and comprehensive performance, respectively. The results showed that the maximum temperature of the hybrid heat sink attained a minimum value with an increase in the splitting distance. The average pressure drop in the center passage of the microchannel first increased and then decreased. Furthermore, the optimal value could not be simultaneously obtained with the maximum temperature. Therefore, it should be comprehensively considered in the optimization design. The heat flux in the hotspot was positively correlated with the maximum heat sink temperature. However, it had no effect on the flow pressure drop. When the Reynolds number and the pin-fin diameter increased, the maximum heat sink temperature decreased and the average pressure drop of the microchannel increased. The comprehensive performance of the hybrid heat sink was not good at small Reynolds numbers, but it significantly improved as the Reynolds number gradually increased. Choosing a bigger pin-fin diameter and the corresponding optimal value of the splitting distance in a given Reynolds number would further improve the comprehensive performance of a hybrid heat sink.
- 2 December 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (12) , 2136
Open AccessThermal–Hydrodynamic Behavior and Design of a Microchannel Pin-Fin Hybrid Heat Sink
A three-dimensional convective heat transfer model of a microchannel pin-fin hybrid heat sink was established. Considering the non-uniform heat generation of 3D stacked chips, the splitting distance of pin-fins was optimized by minimizing the maximum heat sink temperature under different heat fluxes in the hotspot, the Reynolds numbers at the entrance of the microchannel, and the proportions of the pin-fin volume. The average pressure drop and the performance evaluation criteria were considered to be the performance indexes to analyze the influence of each parameter on the flow performance and comprehensive performance, respectively. The results showed that the maximum temperature of the hybrid heat sink attained a minimum value with an increase in the splitting distance. The average pressure drop in the center passage of the microchannel first increased and then decreased. Furthermore, the optimal value could not be simultaneously obtained with the maximum temperature. Therefore, it should be comprehensively considered in the optimization design. The heat flux in the hotspot was positively correlated with the maximum heat sink temperature. However, it had no effect on the flow pressure drop. When the Reynolds number and the pin-fin diameter increased, the maximum heat sink temperature decreased and the average pressure drop of the microchannel increased. The comprehensive performance of the hybrid heat sink was not good at small Reynolds numbers, but it significantly improved as the Reynolds number gradually increased. Choosing a bigger pin-fin diameter and the corresponding optimal value of the splitting distance in a given Reynolds number would further improve the comprehensive performance of a hybrid heat sink.