Qi-Wei Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qi-Wei Dong has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Desheng Xu
Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing 100124, China
1 shared publication - Fei Xie
Beijing General Municipal Engineering Design & Research Institute, Beijing 100082, China
1 shared publication Ji-Dong Wang
Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology Beijing 100124, China
1 shared publicationJun-Mei Li
Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology Beijing 100124, China
1 shared publication- Junmei Li
Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing 100124, China
1 shared publication Xiao Feng
Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology Beijing 100124, China
1 shared publication
Latest Publications
- Open Access
The Influence of Confined Space Size on the Temperature Distribution Characteristics of Internal Window Plume from Well-Ventilated Compartment Fires
In this research, the influence of confined space size on the temperature distribution characteristics of internal window plumes from well-ventilated compartment fires was studied. Theoretical analysis was firstly used to establish a mathematical model for the smoke after ejecting from the window in the space. The study considered fire heat release rate and vertical height as dependent variables. Numerical simulations and experimental methods were carried out to study the temperature variations. A critical distance L2 was obtained. Results show that when the space D between the vertical retaining wall and the building façade is greater than L2, the variation of D has little influence on radial temperature. Once D is less than L2, the radial temperature distribution inside the confined space will tend to be consistent, and the temperature in the confined space sharply increases as D decreases. In addition, a dimensionless model was derived to quantify the relationship between temperature rise and vertical height. The experimental and numerical simulation results were processed, which are in good agreement with the model. The study can provide a framework for managing building safety.
Open AccessThe Influence of Confined Space Size on the Temperature Distribution Characteristics of Internal Window Plume from Well-Ventilated Compartment Fires
In this research, the influence of confined space size on the temperature distribution characteristics of internal window plumes from well-ventilated compartment fires was studied. Theoretical analysis was firstly used to establish a mathematical model for the smoke after ejecting from the window in the space. The study considered fire heat release rate and vertical height as dependent variables. Numerical simulations and experimental methods were carried out to study the temperature variations. A critical distance L2 was obtained. Results show that when the space D between the vertical retaining wall and the building façade is greater than L2, the variation of D has little influence on radial temperature. Once D is less than L2, the radial temperature distribution inside the confined space will tend to be consistent, and the temperature in the confined space sharply increases as D decreases. In addition, a dimensionless model was derived to quantify the relationship between temperature rise and vertical height. The experimental and numerical simulation results were processed, which are in good agreement with the model. The study can provide a framework for managing building safety.
- Open Access
- 1 January 2018
- Published by Elsevier in Procedia Engineering
- Vol. 211, 137-141
Analysis of Ventilating Network for an Urban Underground Road with Multi-point Entry and Exit
- 1 January 2018
- Published by Elsevier in Procedia Engineering
- Vol. 211, 137-141
Open AccessAnalysis of Ventilating Network for an Urban Underground Road with Multi-point Entry and Exit