H. Kudo
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
H. Kudo has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
A. Tsukune
Fujitsu Laboratories Limited
4 shared publicationsT. Futatsugi
Fujitsu Laboratories Limited
4 shared publicationsT. Sugii
Fujitsu Laboratories Limited
4 shared publicationsH. Kitada
Fujitsu Laboratories Limited
3 shared publicationsH. Matsuyama
Fujitsu Laboratories Limited, Fujitsu Limited, 50 Fuchigami, Akiruno, Tokyo, 197-0833, Japan
3 shared publicationsH. Ochimizu
Fujitsu Laboratories Limited
3 shared publications
Latest Publications
- 1 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 2380632X,p. 117-119
Further Enhancement of Electro-migration Resistance by Combination of Self-aligned Barrier and Copper Wiring Encapsulation Techniques for 32-nm Nodes and Beyond
To further enhance electro-migration resistance, we applied a self-aligned barrier technique to Cu wiring encapsulated with a MnO barrier. This combination of the self-aligned barrier and encapsulation techniques increased maximum current density to 9 times that of the conventional one. The Cu wiring fabricated by the combination of the two techniques also had greater resistance to stress-induced voiding set off by thermal stress. The combination of the two techniques also enhanced the lifetime of time-dependent dielectric breakdown by a factor of 160.
- 1 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 2380632X,p. 117-119
Further Enhancement of Electro-migration Resistance by Combination of Self-aligned Barrier and Copper Wiring Encapsulation Techniques for 32-nm Nodes and Beyond
To further enhance electro-migration resistance, we applied a self-aligned barrier technique to Cu wiring encapsulated with a MnO barrier. This combination of the self-aligned barrier and encapsulation techniques increased maximum current density to 9 times that of the conventional one. The Cu wiring fabricated by the combination of the two techniques also had greater resistance to stress-induced voiding set off by thermal stress. The combination of the two techniques also enhanced the lifetime of time-dependent dielectric breakdown by a factor of 160.
- 1 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 2380632X,p. 93-95
Enhancing Yield and Reliability by Applying Dry Organic Acid Vapor Cleaning to Copper Contact Via-Bottom for 32-nm Nodes and Beyond
Via cleaning using gas-phase organic acid has a high potential for improving the reduction capability of copper oxides (CuO), not degrading porous ultra-low-k dielectrics, and reducing processing cost. We applied our via cleaning technique to intermediate and semi-global levels consisting of homogeneous interlayer dielectric architectures based on the 45-nm technology node. The CuO reduction rate was by a factor of 10, which was much higher compared with that using hydrogen. This allowed us to achieve a 100% yield for a mega-scaled via chain. Via chains treated with gas-phase organic acid also showed greater resistance against stress-induced voiding. In addition, we substantially reduced the via cleaning process cost by a factor of 10 compared with the cost of conventional wet chemical cleaning. In addition, organic acid is preferable because it occurs naturally and is thus ecologically friendly.
- 1 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 2380632X,p. 93-95
Enhancing Yield and Reliability by Applying Dry Organic Acid Vapor Cleaning to Copper Contact Via-Bottom for 32-nm Nodes and Beyond
Via cleaning using gas-phase organic acid has a high potential for improving the reduction capability of copper oxides (CuO), not degrading porous ultra-low-k dielectrics, and reducing processing cost. We applied our via cleaning technique to intermediate and semi-global levels consisting of homogeneous interlayer dielectric architectures based on the 45-nm technology node. The CuO reduction rate was by a factor of 10, which was much higher compared with that using hydrogen. This allowed us to achieve a 100% yield for a mega-scaled via chain. Via chains treated with gas-phase organic acid also showed greater resistance against stress-induced voiding. In addition, we substantially reduced the via cleaning process cost by a factor of 10 compared with the cost of conventional wet chemical cleaning. In addition, organic acid is preferable because it occurs naturally and is thus ecologically friendly.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 01631918,p. 513-516
Copper Wiring Encapsulation with Ultra-thin Barriers to Enhance Wiring and Dielectric Reliabilities for 32-nm Nodes and Beyond
We successfully encapsulated Cu wiring with an ultra-thin self-forming barrier consisting of MnO and a bi-layer of MnO/Ta. TDDB test showed that the ILDs lifetime increased by a factor of 100 over that of our control sample. The encapsulated Cu wiring increased EM lifetime by a factor of more than 47. For via chains that are vulnerable to thermal stress, the encapsulated Cu wiring showed no SIV failure. The resistance of the encapsulated Cu wiring was 13% lower than that of the control sample. We expect encapsulated Cu wiring to have greater endurance to the electrical and thermal stresses for use in 32-nm nodes and beyond.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 01631918,p. 513-516
Copper Wiring Encapsulation with Ultra-thin Barriers to Enhance Wiring and Dielectric Reliabilities for 32-nm Nodes and Beyond
We successfully encapsulated Cu wiring with an ultra-thin self-forming barrier consisting of MnO and a bi-layer of MnO/Ta. TDDB test showed that the ILDs lifetime increased by a factor of 100 over that of our control sample. The encapsulated Cu wiring increased EM lifetime by a factor of more than 47. For via chains that are vulnerable to thermal stress, the encapsulated Cu wiring showed no SIV failure. The resistance of the encapsulated Cu wiring was 13% lower than that of the control sample. We expect encapsulated Cu wiring to have greater endurance to the electrical and thermal stresses for use in 32-nm nodes and beyond.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 2380632X,p. 178-180
Strategies of RC Delay Reduction in 45 nm BEOL Technology
According to the 45 nm BEOL technology node, we demonstrated that a homogeneous interlayer dielectric with dielectric constant of 2.25 has a substantial advantage in terms of RC delay reduction compared to other potential architectures such as hybrid and tri-level dielectrics. Combination of the homogeneous interlayer dielectric and ultra-thinned barrier metal lowered the RC delay to 86 % compared to that listed in the ITRS 2006 update.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 2380632X,p. 178-180
Strategies of RC Delay Reduction in 45 nm BEOL Technology
According to the 45 nm BEOL technology node, we demonstrated that a homogeneous interlayer dielectric with dielectric constant of 2.25 has a substantial advantage in terms of RC delay reduction compared to other potential architectures such as hybrid and tri-level dielectrics. Combination of the homogeneous interlayer dielectric and ultra-thinned barrier metal lowered the RC delay to 86 % compared to that listed in the ITRS 2006 update.