Seong Kuk Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Seong Kuk Han has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Eunhye Song
Hydrogen Energy Solution Center, Institute for Advanced Engineering, Yongin-si 17180, Gyeonggi-do, Republic of Korea
3 shared publications - Cheol Jin Jeong
Bio Resource Center, Institute for Advanced Engineering, Yongin-si 17180, Gyeonggi-do, Republic of Korea
2 shared publications - Eun Ju Kim
Bio Resource Center, Institute for Advanced Engineering, Yongin-si 17180, Gyeonggi-do, Republic of Korea
2 shared publications - Eun Sil Lee
Center for Plant Engineering, Institute for Advanced Engineering, Yongin-si 17180, Korea
1 shared publication - Ho Kim
Center for Bio Resource, Institute for Advanced Engineering, Yongin-si 17180, Korea
1 shared publication - Kyung Woo Kim
Center of Bioresource, Institute for Advanced Engineering, Yongin 175-28, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 12 September 2025
- Published by MDPI AG in Clean Technologies
- Vol. 7 (3) , 82
Real-Time Sensor-Controlled Coagulant Dosing and Pressure in a Novel Sludge Dewatering System
Sludge dewatering remains a resource-intensive process, often constrained by high residual moisture content and inefficient chemical conditioning. Conventional systems typically rely on fixed polymer dosages and predetermined filtration pressures, which are unable to respond to variations in sludge characteristics, resulting in inconsistent and suboptimal performance. In this study, a real-time control system for municipal wastewater sludge dewatering was developed to dynamically regulate coagulant dosing and filtration pressure based on continuous monitoring of critical sludge parameters, including total solids (TS), viscosity, sludge temperature, and pH change following coagulant addition. The control logic, derived from empirical correlations between sludge dewaterability metrics such as time-to-filter (TTF) and capillary suction time (CST) and operational variables, enables adaptive adjustment of polyoxyethylene alkyl ether (POAE) injection and pressing conditions. Implementation of this system achieved a final cake moisture content of approximately 63% after 60 min of filtration, substantially lower than the ~84% moisture observed under static conditions. Real-time flux feedback facilitated timely pressure escalation (from 15 to 20 bar to 25–30 bar), improving water removal efficiency while avoiding premature cake blinding. The pH drop (~0.7 units) post-polymer addition served as a practical indicator of adequate flocculation, supporting dose optimization and minimizing chemical waste. The proposed system demonstrated enhanced dewatering performance, reduced polymer consumption, and greater operational robustness compared to conventional approaches. These findings highlight the potential of integrated sensor-based control to advance sludge treatment technologies by promoting smarter, adaptive, and resource-efficient dewatering operations.
- 12 September 2025
- Published by MDPI AG in Clean Technologies
- Vol. 7 (3) , 82
Open AccessReal-Time Sensor-Controlled Coagulant Dosing and Pressure in a Novel Sludge Dewatering System
Sludge dewatering remains a resource-intensive process, often constrained by high residual moisture content and inefficient chemical conditioning. Conventional systems typically rely on fixed polymer dosages and predetermined filtration pressures, which are unable to respond to variations in sludge characteristics, resulting in inconsistent and suboptimal performance. In this study, a real-time control system for municipal wastewater sludge dewatering was developed to dynamically regulate coagulant dosing and filtration pressure based on continuous monitoring of critical sludge parameters, including total solids (TS), viscosity, sludge temperature, and pH change following coagulant addition. The control logic, derived from empirical correlations between sludge dewaterability metrics such as time-to-filter (TTF) and capillary suction time (CST) and operational variables, enables adaptive adjustment of polyoxyethylene alkyl ether (POAE) injection and pressing conditions. Implementation of this system achieved a final cake moisture content of approximately 63% after 60 min of filtration, substantially lower than the ~84% moisture observed under static conditions. Real-time flux feedback facilitated timely pressure escalation (from 15 to 20 bar to 25–30 bar), improving water removal efficiency while avoiding premature cake blinding. The pH drop (~0.7 units) post-polymer addition served as a practical indicator of adequate flocculation, supporting dose optimization and minimizing chemical waste. The proposed system demonstrated enhanced dewatering performance, reduced polymer consumption, and greater operational robustness compared to conventional approaches. These findings highlight the potential of integrated sensor-based control to advance sludge treatment technologies by promoting smarter, adaptive, and resource-efficient dewatering operations.
- Open Access
Evaluation of Ultrasonic Cleaning Characteristics of Filter Cloth in Filter Press Cleaning System
In this study, ultrasonic excitation was employed for filter cloth cleaning, with the aim of predicting optimal cleaning conditions and monitoring the efficiency and performance of the cloth under various cleaning parameters. A clogged filter cloth of uniform size (Φ0.11 m) was secured in a prepared cleaning apparatus, and cleaning experiments were conducted by varying the following operational conditions: time (2, 5, 10 min), frequency (34, 76, 120 kHz), and power output (100, 200, 300 W). Through these experiments, this study sought to investigate the cleaning capacity and efficiency of each condition and to evaluate the effectiveness of ultrasonic cleaning. The morphology of the filter cloths before and after cleaning was examined through SEM imaging, and the weight content of the filter cloths was measured before and after the cleaning experiments to incorporate these values into the cleaning efficiency assessment. Additionally, air permeability measurements were taken to predict the impact of permeability on cleaning performance, which was statistically analyzed based on a predictive model’s equation. The experimental results showed that the maximum recovery rate of air permeability for clogged filter cloths was approximately 28.6%. Using Response Surface Methodology (RSM), the air permeability recovery rate and weight reduction rate were 19.8% and 5.8%, respectively, under conditions of 5.2 min, 34 kHz, and 300 W. It is anticipated that the utilization of the filter press cleaning device will enable data acquisition through repeated experiments and that this device can be used in filter cloth management and operational techniques.
Open AccessEvaluation of Ultrasonic Cleaning Characteristics of Filter Cloth in Filter Press Cleaning System
In this study, ultrasonic excitation was employed for filter cloth cleaning, with the aim of predicting optimal cleaning conditions and monitoring the efficiency and performance of the cloth under various cleaning parameters. A clogged filter cloth of uniform size (Φ0.11 m) was secured in a prepared cleaning apparatus, and cleaning experiments were conducted by varying the following operational conditions: time (2, 5, 10 min), frequency (34, 76, 120 kHz), and power output (100, 200, 300 W). Through these experiments, this study sought to investigate the cleaning capacity and efficiency of each condition and to evaluate the effectiveness of ultrasonic cleaning. The morphology of the filter cloths before and after cleaning was examined through SEM imaging, and the weight content of the filter cloths was measured before and after the cleaning experiments to incorporate these values into the cleaning efficiency assessment. Additionally, air permeability measurements were taken to predict the impact of permeability on cleaning performance, which was statistically analyzed based on a predictive model’s equation. The experimental results showed that the maximum recovery rate of air permeability for clogged filter cloths was approximately 28.6%. Using Response Surface Methodology (RSM), the air permeability recovery rate and weight reduction rate were 19.8% and 5.8%, respectively, under conditions of 5.2 min, 34 kHz, and 300 W. It is anticipated that the utilization of the filter press cleaning device will enable data acquisition through repeated experiments and that this device can be used in filter cloth management and operational techniques.
- Open Access
Dewaterability Enhancement of Anaerobic Sludge Using Polymeric Aluminum Chloride and Polyoxyethylene Alkyl Ether Surfactants
The use of coagulants, such as ferric chloride hexahydrate, in wastewater treatment processes is known to induce pipe corrosion and to contribute to the discoloration of treated water. This study explores alternative approaches to sludge dewatering by evaluating the effectiveness of polymeric aluminum chloride (PAC) as a coagulant and polyoxyethylene alkyl ether (POAE) as a surfactant. The impacts of coagulation/flocculation were assessed using time to filtration (TTF) and a pressure filter press. The effects of certain coagulant and surfactant dosages were studied. The inputs were in the range of 105–1750 mg/L for PAC and 28–152 mg/L for POAE, which were determined based on zeta potential (ZP) measurements. The optimal concentrations were 876 mg/L for PAC and 114 mg/L for POAE, resulting in a TTF of less than 1 min. Moreover, the effect of pH on anaerobic sludge dewaterability was investigated. At a low pH below 8, the ZP reached the maximum value, and a higher pH resulted in a reduction in ZP. Under low-pH adjustments, it was observed that the dewatering performance of the POAE surfactant improved more significantly than that of the PAC coagulant. In addition, the effect of pressure was analyzed using a pressure filter under conditions favoring POAE, with relatively lower dosages and greater cost-effectiveness. In order to evaluate the solubility of organic matter under pressurized conditions, the filtrate’s removal efficiency, chemical oxygen demand (COD), and total phosphorus (TP) were investigated. Solubilization did not occur at an increased pressure of around 10 bars. The findings presented in this study provide technical assistance for sludge treatment.
Open AccessDewaterability Enhancement of Anaerobic Sludge Using Polymeric Aluminum Chloride and Polyoxyethylene Alkyl Ether Surfactants
The use of coagulants, such as ferric chloride hexahydrate, in wastewater treatment processes is known to induce pipe corrosion and to contribute to the discoloration of treated water. This study explores alternative approaches to sludge dewatering by evaluating the effectiveness of polymeric aluminum chloride (PAC) as a coagulant and polyoxyethylene alkyl ether (POAE) as a surfactant. The impacts of coagulation/flocculation were assessed using time to filtration (TTF) and a pressure filter press. The effects of certain coagulant and surfactant dosages were studied. The inputs were in the range of 105–1750 mg/L for PAC and 28–152 mg/L for POAE, which were determined based on zeta potential (ZP) measurements. The optimal concentrations were 876 mg/L for PAC and 114 mg/L for POAE, resulting in a TTF of less than 1 min. Moreover, the effect of pH on anaerobic sludge dewaterability was investigated. At a low pH below 8, the ZP reached the maximum value, and a higher pH resulted in a reduction in ZP. Under low-pH adjustments, it was observed that the dewatering performance of the POAE surfactant improved more significantly than that of the PAC coagulant. In addition, the effect of pressure was analyzed using a pressure filter under conditions favoring POAE, with relatively lower dosages and greater cost-effectiveness. In order to evaluate the solubility of organic matter under pressurized conditions, the filtrate’s removal efficiency, chemical oxygen demand (COD), and total phosphorus (TP) were investigated. Solubilization did not occur at an increased pressure of around 10 bars. The findings presented in this study provide technical assistance for sludge treatment.
- Open Access
Characteristics of Hydrothermal Carbonization Hydrochar Derived from Cattle Manure
The characteristics of hydrothermal carbonization hydrochar derived from cattle manure including excrements and lignocellulosic biomass were analyzed. The effects of hydrothermal carbonization were evaluated by varying the reaction temperatures in the range of 180~240 °C. The hydrochars were evaluated with respect to their usefulness as renewable fuels via physicochemical analysis and pyrolysis processes. As reaction temperatures increased, the fractions of fixed carbon in proximate analyses, carbon elements in ultimate analyses, and higher heating values of hydrothermally carbonized biochars increased in correlation with the primary reactions of coalification. Various correlations were derived with the characteristics of hydrochars in order to be utilized for operating and designing HTC reactors for cattle manure. The correlation between the O/C and H/C ratios was deduced on the basis of a van Krevelen diagram. The interaction equation was represented with the increased fraction of HHV compared to the reaction temperature of hydrothermal carbonization. The ultimate correlation for the estimation of higher heating values was suggested for HTC hydrochars. Moreover, the pyrolysis characteristics and kinetic parameters of the cattle manure and hydrochar were deduced by utilizing a multi-step kinetic model scheme. As the HTC reaction temperature increased, the global activation energy and the pre-exponential factors of hydrochars decreased in the low-temperature section and increased in the high-temperature section.
Open AccessCharacteristics of Hydrothermal Carbonization Hydrochar Derived from Cattle Manure
The characteristics of hydrothermal carbonization hydrochar derived from cattle manure including excrements and lignocellulosic biomass were analyzed. The effects of hydrothermal carbonization were evaluated by varying the reaction temperatures in the range of 180~240 °C. The hydrochars were evaluated with respect to their usefulness as renewable fuels via physicochemical analysis and pyrolysis processes. As reaction temperatures increased, the fractions of fixed carbon in proximate analyses, carbon elements in ultimate analyses, and higher heating values of hydrothermally carbonized biochars increased in correlation with the primary reactions of coalification. Various correlations were derived with the characteristics of hydrochars in order to be utilized for operating and designing HTC reactors for cattle manure. The correlation between the O/C and H/C ratios was deduced on the basis of a van Krevelen diagram. The interaction equation was represented with the increased fraction of HHV compared to the reaction temperature of hydrothermal carbonization. The ultimate correlation for the estimation of higher heating values was suggested for HTC hydrochars. Moreover, the pyrolysis characteristics and kinetic parameters of the cattle manure and hydrochar were deduced by utilizing a multi-step kinetic model scheme. As the HTC reaction temperature increased, the global activation energy and the pre-exponential factors of hydrochars decreased in the low-temperature section and increased in the high-temperature section.