Fatima Zohra Bakhti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fatima Zohra Bakhti has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Mohamed Si-Ameur
LESEI Laboratory Avenue Chahid Boukhlouf Med Elhadi 05000 Batna Algeria
3 shared publications- Adnan Ibrahim
Solar Energy Research Institute, Universiti Kebangsaan Malaysia, Bangi, Malaysia
1 shared publication - Amel Djebara1 shared publication
Belqassim Zerguine
Mechanical Department, Faculty of Technology, University of Blida, Blida, Algeria
1 shared publication- Khaled M. Al-Aribe
The Univ. of Western Ontario (Canada)
1 shared publication - Mohamed Si-Ameur
Labratoire des Systemes Energétiques et Industrielles (LESEI), University of Batna 2 2 , Batna 05000
1 shared publication
Latest Publications
- Open Access
- 20 July 2026
- Published by Elsevier in International Journal of Thermofluids
- Vol. 35
Thermal Performance Improvement of a Cylindrical-Parabolic Collector using Twisted Tapes and Nanofluids: Thermofluid Optimisation and Exergy Considerations
- 20 July 2026
- Published by Elsevier in International Journal of Thermofluids
- Vol. 35
Open AccessThermal Performance Improvement of a Cylindrical-Parabolic Collector using Twisted Tapes and Nanofluids: Thermofluid Optimisation and Exergy Considerations
- Open Access
- 28 November 2025
- Published by Acadlore Publishing Services Limited in International Journal of Energy Production and Management
- Vol. 10 (03) , 436-455
3D Simulation of Thermo-Hydraulic Enhancement of Flat-Plate Solar Collector Equipped with Twisted Tape
Flat plate solar collectors are widely employed in applications operating at low to moderate temperatures, including domestic water heating and various industrial uses. Their thermal performance is strongly influenced by the absorber tube, through which solar energy is transmitted to the circulating fluid. Conventional designs are often limited by low convective heat transfer, which has motivated studies on geometric enhancements to improve overall efficiency. The present work examines the thermo-hydraulic characteristics of a flat plate solar air collector fitted with twisted tape inserts having various twist ratios (δ = 3, 4, 5, 6), and compares the results with a plain tube collector. Air serves as the working fluid, and simulations were carried out over a Reynolds number range of 200-2000. A three-dimensional CFD approach was employed to study critical performance characteristics, including outlet temperature, Nusselt number, friction factor, pumping power, and thermal efficiency. The results show that twisted tape collector (TTC) provide considerably greater heat transfer compared to the plain collector (PC). At Re = 1000, the Nusselt number enhancement reached 35.19%, 44.55%, 50.15%, and 54.96% for twist ratios δ = 6, 5, 4, and 3, respectively. Although this improvement is associated with increased pressure drops, the findings confirm that twisted tape inserts substantially enhance the heat transfer effectiveness of solar collectors by promoting turbulence and better fluid mixing.
- 28 November 2025
- Published by Acadlore Publishing Services Limited in International Journal of Energy Production and Management
- Vol. 10 (03) , 436-455
Open Access3D Simulation of Thermo-Hydraulic Enhancement of Flat-Plate Solar Collector Equipped with Twisted Tape
Flat plate solar collectors are widely employed in applications operating at low to moderate temperatures, including domestic water heating and various industrial uses. Their thermal performance is strongly influenced by the absorber tube, through which solar energy is transmitted to the circulating fluid. Conventional designs are often limited by low convective heat transfer, which has motivated studies on geometric enhancements to improve overall efficiency. The present work examines the thermo-hydraulic characteristics of a flat plate solar air collector fitted with twisted tape inserts having various twist ratios (δ = 3, 4, 5, 6), and compares the results with a plain tube collector. Air serves as the working fluid, and simulations were carried out over a Reynolds number range of 200-2000. A three-dimensional CFD approach was employed to study critical performance characteristics, including outlet temperature, Nusselt number, friction factor, pumping power, and thermal efficiency. The results show that twisted tape collector (TTC) provide considerably greater heat transfer compared to the plain collector (PC). At Re = 1000, the Nusselt number enhancement reached 35.19%, 44.55%, 50.15%, and 54.96% for twist ratios δ = 6, 5, 4, and 3, respectively. Although this improvement is associated with increased pressure drops, the findings confirm that twisted tape inserts substantially enhance the heat transfer effectiveness of solar collectors by promoting turbulence and better fluid mixing.
- 27 November 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 238 (1) , 144-157
Enhancement of the cooling by mixed convection of a CPU using a rotating heat sink: Numerical study
The technological progress made in recent years has driven electronic apparatus to become not only more efficient and work faster but also considerably smaller in weight and size. Furthermore, the power densities of these devices have known an impressive increase. However, the challenge for the electronic industry is the lifetime device improvement by controlling the adequate removal of their excess heat. The use of more efficient cooling systems is, therefore, crucial in order to ensure durable device functionality. In this work, computational simulation was carried out to study the enhancement cooling process mixed convection of an electronic component (CPU mounted in a motherboard) using a new design of a heat exchanger by combining the heat sink (the finned surface) and the fan in a single component, this allows more heat to be moved faster and with less energy than a conventional cooler. Three radial heat sinks (HS18, HS24 and HS36) are considered depending on circumferential fin numbers ( n = 18, 24 and 36). The effect of Reynolds number, heat flux and rotational velocity is investigated, and the optimum comprehensive performance was determined. The results reveal the cooling performance turns out to be better for heat sink with n = 36. The rotational velocity operates a significant effect on the temperature field only for values below than 900 rpm. We also found that the improvement in the Nusselt number and its percentage enhancement is intensified with increased rotational velocity and decreased with heat flux. A bigger Ω and Re Ω meant a more obvious heat transfer enhancement (Nu Ω /Nu 0 ) in the case of smaller Q, but (Nu Ω /Nu 0 ) decreased with increasing Q.
- 27 November 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 238 (1) , 144-157
Enhancement of the cooling by mixed convection of a CPU using a rotating heat sink: Numerical study
The technological progress made in recent years has driven electronic apparatus to become not only more efficient and work faster but also considerably smaller in weight and size. Furthermore, the power densities of these devices have known an impressive increase. However, the challenge for the electronic industry is the lifetime device improvement by controlling the adequate removal of their excess heat. The use of more efficient cooling systems is, therefore, crucial in order to ensure durable device functionality. In this work, computational simulation was carried out to study the enhancement cooling process mixed convection of an electronic component (CPU mounted in a motherboard) using a new design of a heat exchanger by combining the heat sink (the finned surface) and the fan in a single component, this allows more heat to be moved faster and with less energy than a conventional cooler. Three radial heat sinks (HS18, HS24 and HS36) are considered depending on circumferential fin numbers ( n = 18, 24 and 36). The effect of Reynolds number, heat flux and rotational velocity is investigated, and the optimum comprehensive performance was determined. The results reveal the cooling performance turns out to be better for heat sink with n = 36. The rotational velocity operates a significant effect on the temperature field only for values below than 900 rpm. We also found that the improvement in the Nusselt number and its percentage enhancement is intensified with increased rotational velocity and decreased with heat flux. A bigger Ω and Re Ω meant a more obvious heat transfer enhancement (Nu Ω /Nu 0 ) in the case of smaller Q, but (Nu Ω /Nu 0 ) decreased with increasing Q.
- 1 October 2021
- Published by International Information and Engineering Technology Association in International Journal of Heat and Technology
- Vol. 39 (5) , 1417-1429
Elliptical Pin Fin Heat Sink: Passive Cooling Control
- 1 October 2021
- Published by International Information and Engineering Technology Association in International Journal of Heat and Technology
- Vol. 39 (5) , 1417-1429
Elliptical Pin Fin Heat Sink: Passive Cooling Control