SISamroeng Inglam

Samroeng Inglam

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Samroeng Inglam has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • Nattapon Chantarapanich

    Digital Industrial Design and Manufacturing Research Unit and Department of Mechanical Engineering, Faculty of Engineering at Sriracha, Kasetsart University, Chonburi, Thailand

    2 shared publications
  • Chakree Leeisaramas

    Division of Orthodontics, Faculty of Dentistry, Thammasat University, Pathum Thani, Thailand

    1 shared publication
  • Intan Farizka

    Department of Dentomaxillofacial Radiology Faculty of Dentistry Trisakti University 11410 Jakarta Indonesia

    1 shared publication
  • Jackson Dipankara

    Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Universitas Trisakti, Jakarta

    1 shared publication
  • Kanlaya Insee

    Division of Orthodontics, Faculty of Dentistry, Thammasat University, Pathum Thani 12120, Thailand

    1 shared publication
  • Komsan Apinyauppatham

    Faculty of Dentistry, Thammasat University, Pathumthani, Thailand

    1 shared publication

Latest Publications

  • Open Access

    Analysis of Stress Distribution and Displacement Based on the Miniscrew Positions of the Palatal Slope Bone-borne Expander: A Finite Element Study

    by Chakree Leeisaramas, Nattapon Chantarapanich, Samroeng Inglam, Kanlaya Insee

    Objectives This study aimed to investigate the stress distribution pattern of the palatal slope bone-borne expander on the maxillary area according to a different anteroposterior position of anchored miniscrews using finite element analysis. Materials and Methods Nasomaxillary stereolithography files with three different anteroposterior anchored miniscrew positions of the palatal slope bone-borne expander were determined as model A, B, and C. Each model consists of four supported miniscrews. Model A: two anterior miniscrews were located between the maxillary canine and the first premolar, and two posteriors between the second premolar and the first molar. Model B: two anteriors were between the lateral incisor and the canine, and two posteriors were the same as in model A. Model C: two anteriors were the same as in model A, and two posteriors were distal to the first molar. One turn of expander screws was applied. Maximum principal stress, equivalent elastic strain, equivalent von Mises stress, and transverse displacement were evaluated. Results The maximum principal stress was mostly found at the bone-miniscrew interface. Model A exhibited an intersecting area of stress between the supported miniscrews. The highest value of principal stress was in model B, while model C showed a uniform distribution pattern. The elastic strain pattern was similar to the principal stress in all models. The highest value of equivalent von Mises stress was located on the expander screw. The largest amount of transverse displacement of teeth was in model A, while model C exhibited a more consistent transverse displacement than other models. Vertical displacement of posterior teeth was also noticed. Conclusion Based on the result, it revealed that the various anteroposterior miniscrew placements of the palatal slope bone-borne expander had various patterns of stress distribution and resulted in various outcomes. It may be inferred that model A's miniscrew location was advantageous for obtaining expansion quantities, but model C's miniscrew position was advantageous for maintaining consistent biomechanics.


  • Open Access

    Clinical challenges of biomechanical performance of narrow-diameter implants in maxillary posterior teeth in aging patients: A finite element analysis

    by Saranyoo Prasitwuttisak, Nattapon Chantarapanich, Komsan Apinyauppatham, Kopchai Poomparnich, Samroeng Inglam

    This study evaluated the biomechanical performance of narrow-diameter implant (NDI) treatment in atrophic maxillary posterior teeth in aging patients by finite element analysis. The upper left posterior bone segment with first and second premolar teeth missing obtained from a patient’s cone beam computed tomography data was simulated with cortical bone thicknesses of 0.5 and 1.0 mm. Three model groups were analyzed. The Regimen group had NDIs of 3.3 × 10 mm in length with non-splinted crowns. Experimental-1 group had NDIs of 3.0 × 10 mm in length with non-splinted crowns and Experimental-2 group had NDIs of 3.0 × 10 mm in length with splinted crowns. The applied load was 56.9 N in three directions: axial (along the implant axis), oblique at 30° (30° to the bucco-palatal plane compared to the vertical axis of the tooth), and lateral load at 90° (90° in the bucco-palatal plane compared to the vertical axis of the tooth). The results of the von Mises stress on the implant fixture, the elastic strain, and principal value of stress on the crestal marginal bone were analyzed. The axial load direction was comparable in the von Mises stress values in all groups, which indicated it was not necessary to use splinted crowns. The elastic strain values in the axial and oblique directions were within the limits of Frost’s mechanostat theory. The principal value of stress in all groups were under the threshold of the compressive stress and tensile strength of cortical bone. In the oblique and lateral directions, the splinted crown showed better results for both the von Mises stress, elastic strain, and principal value of stress than the non-splinted crown. In conclusion, category 2 NDIs can be used in the upper premolar region of aging patients in the case of insufficient bone for category 3 NDI restorations.


  • Open Access

    Finite Element Analysis of Mandibular Advancement Comparing Hunsuck/Epker and a Novel Modification of the Low Z Plasty Technique of BSSO

    by Sukumal Boonlue, Siripatra Patchanee, Samroeng Inglam, Narissaporn Chaiprakit

    This study analyzed the biomechanical behavior under simulated conditions between a novel modification of the Low Z plasty (NM-Low Z) technique and the conventional Hunsuck–Epker (HE) technique on mandibular advancement surgery. The NM-Low Z technique was developed with the purpose of reducing post-operative complications by facilitating the operative method of lower jaw surgery. The models were investigated under physiological muscular and occlusal loads at 1, 2, 4, 6, and 8 weeks post-operation. Finite element analysis was used to analyze stress distribution, elastic strain, and model displacement. Maximum equivalent von Mises stresses were observed on the fixation system and bone. The elastic strain at the fracture site represented the optimal bone-healing capacity. The NM-Low Z model showed lower stress than the HE model at the 2-week post-operation stage and onwards. The elastic strains observed in both models were situated within the normal range for bone healing. The ranges of displacement for the NM-Low Z model were less than those in the HE model. Based on the data sets studied, the biomechanical study of the NM-Low Z technique can be favorably compared to the conventional HE technique. The NM-Low Z technique promotes post-operation skeletal stability by lowering stress on fixation and bone, with less displacement of the segment during bone-healing periods.


  • Open Access

    Alveolar bones density assessment of dental implant sites using cone-beam computed tomography

    by Wiwiek Poedjiastoeti, Muhamad Novo Perwira Lubis, Yessy Ariesanti, Intan Farizka, Jackson Dipankara, Samroeng Inglam

    Introduction: a preoperative assessment of bone density plays a vital role in the success of dental implant treatment. the maxilla and mandibular alveolar bone had a variety of bone densities. Therefore, dental imaging is an important step before placing a dental implant. Recently, Cone beam computed tomography (CBCT) is widely used in dental medicine and also recommended by AAOMR for preoperative implant placement. The aims of this study is to analyzed the alveolar bone density of the dental implant sites for dental implant planning using CBCT. Methods: ninety-three CBCT data were retrieved from the database of the department of oral and maxillofacial radiology at Dental Hospital Faculty of Dentistry Universitas Trisakti and examined. The recipient sites for dental implant placement were determined based on CBCT data using implant planning software (i-Dixel). The alveolar bones value is recorded in grayscale value (GV). Results: a great variety of alveolar bone density was observed ranging from 134-891 GV. One-way ANOVA was conducted, and statistically significant was only shown at the anterior mandibular region and molar mandibular region. However, no statistical differences were observed when comparing the male and female groups using the T-test. Conclusion: Critical evaluation through dental CBCT can be made before dental implant placement in the alveolar bones. the lowest alveolar bone density was observed in maxillary molar dental implant sites with mean 322 GV and highest alveolar bone density was shown in mandibular anterior dental implant sites with mean 558.8 GV. Determining the bone density at the dental implant site before dental implant placement is crucial. Primary stability and secondary stability is determined by bone density. Therefore, higher value of alveolar bone density is needed for dental implant placement.   Keywords: alveolar bone density assessment; dental implant; cone-beam computed tomography.