Tong Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tong Zhang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Meysam Qadrdan
School of Engineering, Cardiff University, Cardiff, U.K.
2 shared publications Adam Hawkes
1 shared publicationAdib Allahham
1 shared publicationBenoit Couraud
1 shared publication- Chengbin Ma
Shanghai Jiao Tong University
1 shared publication Danny Pudjianto
1 shared publication
Latest Publications
- Open Access
- 2 June 2026
- Published by Elsevier in Applied Energy
- Vol. 420
A knowledge-embedded reinforcement learning framework for energy management of planned integrated energy systems
- 2 June 2026
- Published by Elsevier in Applied Energy
- Vol. 420
Open AccessA knowledge-embedded reinforcement learning framework for energy management of planned integrated energy systems
- Top Cited PapersOpen Access
- 17 October 2024
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 208
A systematic review of modelling methods for studying the integration of hydrogen into energy systems
- 17 October 2024
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 208
Top Cited PapersOpen AccessA systematic review of modelling methods for studying the integration of hydrogen into energy systems
- 18 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Markets, Policy and Regulation
- Vol. 1 (4) , 274-285
Assessing Techno-Economic and Environmental Impacts of Gas Compressor Fleet as a Source of Flexibility to the Power System
In the Great Britain's high-pressure gas transmission network, there are 24 gas compressor stations with 68 operational compressor units of different types and sizes. As of 2021, the aggregate capacity of electric-driven gas compressors was 200 MW. By using linepack as a form of gas storage buffer, the compressors can be operated flexibly to achieve a minimum operational cost under fluctuating electricity prices. Furthermore, since electricity consumed by electric-driven compressors can affect the balance of the power grid, the ability of electric-driven compressor units to regulate their electricity consumption is useful to be quantified. In this paper, the value of flexibility from the hybrid compressor stations (compressor stations in which both electric-driven and gas-driven compressor units exist) is analysed. The operation of the high-pressure gas network in Great Britain was formulated as a Mixed-Integer Second Order Cone Programming (MISOCP) problem. The modelling results show that employing the flexibility from hybrid compressor stations in the gas network can reduce more than 20% of the operational cost and 50% of emissions from the compressor fleet. Furthermore, a cost-benefit analysis was carried out to assess the investment viability of installing electric-driven compressor units. It is demonstrated that the economic feasibility of investing in electric-driven compressors is sensitive to the future carbon price.
- 18 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Markets, Policy and Regulation
- Vol. 1 (4) , 274-285
Assessing Techno-Economic and Environmental Impacts of Gas Compressor Fleet as a Source of Flexibility to the Power System
In the Great Britain's high-pressure gas transmission network, there are 24 gas compressor stations with 68 operational compressor units of different types and sizes. As of 2021, the aggregate capacity of electric-driven gas compressors was 200 MW. By using linepack as a form of gas storage buffer, the compressors can be operated flexibly to achieve a minimum operational cost under fluctuating electricity prices. Furthermore, since electricity consumed by electric-driven compressors can affect the balance of the power grid, the ability of electric-driven compressor units to regulate their electricity consumption is useful to be quantified. In this paper, the value of flexibility from the hybrid compressor stations (compressor stations in which both electric-driven and gas-driven compressor units exist) is analysed. The operation of the high-pressure gas network in Great Britain was formulated as a Mixed-Integer Second Order Cone Programming (MISOCP) problem. The modelling results show that employing the flexibility from hybrid compressor stations in the gas network can reduce more than 20% of the operational cost and 50% of emissions from the compressor fleet. Furthermore, a cost-benefit analysis was carried out to assess the investment viability of installing electric-driven compressor units. It is demonstrated that the economic feasibility of investing in electric-driven compressors is sensitive to the future carbon price.
- 2 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 14 (2) , 826-836
A Day-Ahead Scheduling Model of Power Systems Incorporating Multiple Tidal Range Power Stations
With the global trend to exploit more renewable energy sources, tidal range energy has been gaining more attention recently. This power generation technology is expected to reduce the share of fossil fuels and provide flexibility to the power system. With a pioneering tidal range generation project just granted in Wales and more proposals planned in Great Britain, it is important to study how the incorporation of multiple tidal range power stations will affect power system operation. In this paper, the role of tidal range energy generation in the future Great Britain power system is investigated based on a day-ahead scheduling model of power system incorporating multiple tidal range power stations. In the proposed model, tidal range power stations situated at different sites operate flexibly and in coordination, supporting the power system to reach the minimum operating cost. A case study based on the Great Britain electricity transmission system in 2030 with one tidal barrage and one tidal lagoon was investigated. The results showed that the coordination of flexible tidal range power stations can reduce the power system's operating cost. Furthermore, the energy-storage feature of tidal range power stations can act as a stable source of flexibility in the power system.
- 2 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 14 (2) , 826-836
A Day-Ahead Scheduling Model of Power Systems Incorporating Multiple Tidal Range Power Stations
With the global trend to exploit more renewable energy sources, tidal range energy has been gaining more attention recently. This power generation technology is expected to reduce the share of fossil fuels and provide flexibility to the power system. With a pioneering tidal range generation project just granted in Wales and more proposals planned in Great Britain, it is important to study how the incorporation of multiple tidal range power stations will affect power system operation. In this paper, the role of tidal range energy generation in the future Great Britain power system is investigated based on a day-ahead scheduling model of power system incorporating multiple tidal range power stations. In the proposed model, tidal range power stations situated at different sites operate flexibly and in coordination, supporting the power system to reach the minimum operating cost. A case study based on the Great Britain electricity transmission system in 2030 with one tidal barrage and one tidal lagoon was investigated. The results showed that the coordination of flexible tidal range power stations can reduce the power system's operating cost. Furthermore, the energy-storage feature of tidal range power stations can act as a stable source of flexibility in the power system.
- 1 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 84-87
Optimal load analysis for a two-receiver wireless power transfer system
Wireless power transfer to multiple devices is of great importance to simultaneous charging mobile devices, where coupling system is crucial component determining system efficiency. In a multiple-receiver system, external loads values would affect the coupling efficiency, especially for low quality factor coupling system. In this paper, a two-receiver model is proposed to analysis the optimal external loads that would maximize the coupling efficiency. Optimal loads formulas for a two-receiver system are derived using circuit model and validated using a 13.56MHz printed circuit board coupling system.
- 1 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 84-87
Optimal load analysis for a two-receiver wireless power transfer system
Wireless power transfer to multiple devices is of great importance to simultaneous charging mobile devices, where coupling system is crucial component determining system efficiency. In a multiple-receiver system, external loads values would affect the coupling efficiency, especially for low quality factor coupling system. In this paper, a two-receiver model is proposed to analysis the optimal external loads that would maximize the coupling efficiency. Optimal loads formulas for a two-receiver system are derived using circuit model and validated using a 13.56MHz printed circuit board coupling system.