Melike Sener
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Melike Sener has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Necmettin Kılınç
Department of Physics, Inonu University, Malatya 44280, Türkiye
2 shared publications - Ali Altuntepe
Sivas Bilim ve Teknoloji Universitesi
1 shared publication - Orhan Sisman
FunGlass Alexander Dubček University of Trenčín Trenčín Slovakia
1 shared publication - Recep Zan
Niğde Ömer Halisdemir Üniversitesi
1 shared publication
Latest Publications
- Open Access
AAO-Assisted Nanoporous Platinum Films for Hydrogen Sensor Application
The effects of the porosity and the thickness on the ability of hydrogen sensing is demonstrated through a comparison of compact and nanoporous platinum film sensors. The synthesis of anodic aluminum oxide (AAO) nanotubes with an average pore diameter of less than 100 nm served as the template for the fabrication of nanoporous Pt films using an anodization method. This was achieved by applying a voltage of 40 V in 0.4 M of a phosphoric acid solution at 20 °C. To compare the film and nanoporous Pt, layers of approximately 3 nm and 20 nm were coated on both glass substrates and AAO templates using a sputtering technique. FESEM images monitored the formation of nanoporosity by observing the Pt layers covering the upper edges of the AAO nanotubes. Despite their low thickness and the poor long-range order, the EDX and XRD measurements confirmed and uncovered the crystalline properties of the Pt films by comparing the bare and the Pt deposited AAO templates. The nanoporous Pt and Pt thin film sensors were tested in the hydrogen concentration range between 10–50,000 ppm H2 at room temperature, 50 °C, 100 °C and 150 °C. The results reveal that nanoporous Pt performed higher sensitivity than the Pt thin film and the surface scattering phenomenon can express the hydrogen sensing mechanism of the Pt sensors.
Open AccessAAO-Assisted Nanoporous Platinum Films for Hydrogen Sensor Application
The effects of the porosity and the thickness on the ability of hydrogen sensing is demonstrated through a comparison of compact and nanoporous platinum film sensors. The synthesis of anodic aluminum oxide (AAO) nanotubes with an average pore diameter of less than 100 nm served as the template for the fabrication of nanoporous Pt films using an anodization method. This was achieved by applying a voltage of 40 V in 0.4 M of a phosphoric acid solution at 20 °C. To compare the film and nanoporous Pt, layers of approximately 3 nm and 20 nm were coated on both glass substrates and AAO templates using a sputtering technique. FESEM images monitored the formation of nanoporosity by observing the Pt layers covering the upper edges of the AAO nanotubes. Despite their low thickness and the poor long-range order, the EDX and XRD measurements confirmed and uncovered the crystalline properties of the Pt films by comparing the bare and the Pt deposited AAO templates. The nanoporous Pt and Pt thin film sensors were tested in the hydrogen concentration range between 10–50,000 ppm H2 at room temperature, 50 °C, 100 °C and 150 °C. The results reveal that nanoporous Pt performed higher sensitivity than the Pt thin film and the surface scattering phenomenon can express the hydrogen sensing mechanism of the Pt sensors.
- Open Access
- 1 November 2022
- Published by MDPI AG in Engineering Proceedings
- Vol. 27 (1) , 25
Fabrication of Nanoporous Platinum Films with Dealloying Method for Hydrogen Sensor Application
In this research, a nanoporous platinum film is synthesized using the dealloying method. Platinum–copper (Pt–Cu) alloy films with a thickness of approximately 50 nm are prepared on glass using the magnetron-co-sputtering technique. In order to obtain nanoporous Pt, the Pt–Cu alloy films are dealloyed in 1 M nitric acid solution for different intervals. It is observed that when dealloyed in the nitric acid solution for 5 h, Cu was completely removed from the alloy, and nanoporous Pt with a regular pore structure was obtained. Then, the fabricated nanoporous Pt film is tested for hydrogen detection in the concentration range of 10 ppm and–5% hydrogen at various temperatures. The results demonstrated that the sensitivity of nanoporous Pt is about 6.5 for exposure to 1% hydrogen, and the sensing mechanism of nanoporous Pt could be explained by the surface scattering phenomenon.
- 1 November 2022
- Published by MDPI AG in Engineering Proceedings
- Vol. 27 (1) , 25
Open AccessFabrication of Nanoporous Platinum Films with Dealloying Method for Hydrogen Sensor Application
In this research, a nanoporous platinum film is synthesized using the dealloying method. Platinum–copper (Pt–Cu) alloy films with a thickness of approximately 50 nm are prepared on glass using the magnetron-co-sputtering technique. In order to obtain nanoporous Pt, the Pt–Cu alloy films are dealloyed in 1 M nitric acid solution for different intervals. It is observed that when dealloyed in the nitric acid solution for 5 h, Cu was completely removed from the alloy, and nanoporous Pt with a regular pore structure was obtained. Then, the fabricated nanoporous Pt film is tested for hydrogen detection in the concentration range of 10 ppm and–5% hydrogen at various temperatures. The results demonstrated that the sensitivity of nanoporous Pt is about 6.5 for exposure to 1% hydrogen, and the sensing mechanism of nanoporous Pt could be explained by the surface scattering phenomenon.