AQAbdallah Qubala

Abdallah Qubala

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Abdallah Qubala has a total of 53 co-authors. Here are the top co-authors by number of shared publications:

  • Marcus Winter

    Heidelberg Ion Beam Therapy Center (HIT) Department of Radiation Oncology Heidelberg University Hospital Heidelberg Germany

    4 shared publications
  • Oliver Jäkel

    Heidelberg Ion Beam Therapy Center (HIT) Department of Radiation Oncology Heidelberg University Hospital Heidelberg Germany

    4 shared publications
  • Jehad Shafee

    Heidelberg Ion Beam Therapy Center (HIT) Heidelberg Germany

    3 shared publications
  • Julian Horn

    Heidelberg Ion Beam Therapy Center (HIT) Department of Radiation Oncology Heidelberg University Hospital Heidelberg Germany

    2 shared publications
  • Malte Ellerbrock

    Heidelberg Ion Beam Therapy Center (HIT) Department of Radiation Oncology Heidelberg University Hospital Heidelberg Germany

    2 shared publications
  • Anahita Bakhtiari Moghaddam

    Medical Physics in Radiation Oncology, DKFZ, Im Neuenheimer Feld 280,69120 Heidelberg Germany, Heidelberg, 69120, Germany

    1 shared publication

Latest Publications

  • Open Access

    A systematic review on the clinical implementation of 4D particle therapy

    by Sabine Visser, Abdallah Qubala, Karin M Andersson, Pablo Cabello-García, Katarzyna Czerska, Stella Flampouri, Francesco Fracchiolla, Barbara Knäusl, Antje-Christin Knopf, Andrew Gosling, et al.

    Intrafractional motion in the thoracic and abdominal regions remains a major challenge in particle therapy representing one of the key anatomical changes during radiotherapy. Interfractional changes further contribute to cumulative uncertainties and may require adaptive strategies over the course of treatment. The high dose conformality and steep dose fall-off of particle beams, combined with motion-induced range variations, make dose delivery highly sensitive to temporal and anatomical changes. This systematic review provides an overview of clinically implemented 4D treatment approaches addressing intrafractional motion for thoracic and abdominal indications, aiming to support harmonisation of clinical practices across centres and vendors. Systematic searches in PubMed and Web of Science identified relevant publications from January 2020 to December 2025 covering the full 4D workflow in particle therapy. The focus was on clinical implementation for lung, pancreas, liver, lymphoma, oesophagus, and breast, complemented by phantom studies and ongoing research activities. Publications were screened by eight experts using predefined inclusion and exclusion criteria. Writing and synthesis were conducted by a multidisciplinary panel of eighteen experts. A total of 751 publications were identified, of which 231 were included and categorised into six key subtopics: motion management, imaging, treatment planning optimisation and evaluation, clinical indications, phantom studies, and future perspectives. The results confirm that intrafractional motion remains a major source of uncertainty across the workflow. Despite numerous proposed 4D techniques, clinical implementation varies widely. A key limitation is the lack of standardised methods for 4D dose evaluation and interplay assessment, particularly relevant for hypofractionated treatments and advanced delivery techniques. Increasing clinical experience demonstrates that motion-related challenges can be effectively managed using appropriate 4D-aware workflows. This review represents an important step towards establishing consensus and developing guidelines for treating moving targets in particle therapy.

  • Open Access

    End-to-end testing of an online adaptive radiotherapy workflow for liver tumors using a dynamic thoraco-abdominal anthropomorphic phantom

    by Anahita Bakhtiari Moghaddam, Raquel Figueiredo Augusto, Patrick Darremont, Armin Runz, Gernot Echner, Wibke Johnen, Peter Häring, Clemens Lang, Mona Lifferth, Abdallah Qubala, et al.

    Objective:Adaptive radiotherapy (ART) requires robust end-to-end (E2E) testing tools capable of reproducing organ deformation, physiological motion, and multimodal imaging properties. The TAM-ARa (T horacic A nthropomorphic Phantom with M otion for A daptive Ra diotherapy) is a dynamic anthropomorphic phantom developed to validation and quality assurance of online ART workflows. Approach:The phantom was constructed with anatomically realistic bone, lung, and abdominal organ models fabricated from tissue equivalent materials. Modular components allowed simulation of interfractional and intrafractional anatomical variations, including ventilator driven respiratory motion, abdominal deformation, and variable gastric filling. CT, CBCT, and 3T MRI scans were acquired to assess imaging performance. Two E2E tests of an online adaptive IMRT workflow for liver tumors were performed on a Varian Ethos (ETHOS, Varian, USA) system. Multiple deformation scenarios were investigated, including a static reference configuration, two abdominal and one thoracic deformation for ionization chamber (IC) dosimetry, and a static plus abdominal deformation scenarios for radiochromic film dosimetry. Main results:The TAM-ARa phantom demonstrated realistic radiological characteristics, with CT Hounsfield units and MRI relaxation times closely matching reported in vivo values. The modular design allowed reproducible and controlled abdominal deformations, while setup and dosimeter placement were completed within minutes. In E2E tests for adaptive IMRT of liver tumors, excellent agreement was achieved between measured and planned dose after the treatment plan was adapted. IC E2E measurements showed that online adaptation consistently restored accurate dose delivery under deformation, reducing deviations to below 3%. Independent film measurements confirmed sub-millimeter geometric accuracy and full planning target volume coverage after adaptation, demonstrating effective compensation of deformation-induced errors. Significance:The TAM-ARa phantom provides a versatile and reproducible platform for multimodal E2E testing and validation of online ART workflows. Employing its realistic anatomical design, modular structure, and motion capabilities, TAM-ARa was successfully applied for E2E tests to validate a workflow for adaptive IMRT of liver tumors.


  • Open Access

    Patient‐specific quality assurance at the Heidelberg Ion Beam Therapy Center: 10 years experience in treatment plan verification

    by Abdallah Qubala, Christian P. Karger, Julian Horn, Marcus Winter, Malte Ellerbrock, Oliver Jäkel, Katrin Henkner

    Background: To ensure accurate, safe, and reproducible patient treatments, it is essential to have precise knowledge and a solid understanding of patient‐specific quality assurance (PSQA). For many years, the delivery of doses to all patients has been verified using dosimetric measurements. However, these measurements require substantial work, and the reasons for the occasional deviations are unclear. For these reasons, alternative methods such as independent dose calculations (IDCs) and analysis of beam‐monitor log files are increasingly discussed in the particle therapy community. Nevertheless, before replacing dose‐verification measurements with other methods, existing measurement data should be thoroughly analyzed to determine what can be learned from them and how they compare with potential alternatives. These alternative methods are mentioned in this work only to provide context and to outline possible directions for future studies. Purpose: To evaluate the dosimetric accuracy and efficiency of PSQA using a water phantom (WP) over a 10‐year period at the Heidelberg Ion Beam Therapy Center (HIT). Methods: Between 2016 and 2025, 23014 treatment fields with protons, carbon, or helium ions were verified using a WP equipped with 24 pinpoint ionization chambers. The patient treatment plans were recalculated in the water phantom geometry and compared to measured absolute doses. The data were categorized by treatment room, ion species, treatment planning systems (TPS), range shifter (RaShi) use, indication, depth, and target volume, excluding measurements with human errors. Statistical analysis compared measured and calculated doses, focusing on mean, maximum, and minimum dose deviations. Furthermore, the workflow efficiency was assessed based on the beam time required for dosimetric verification, as well as the total time needed for preparation and analysis. Results: Mean dose deviations were in general slightly negative ( t ‐test, p < 0.01), within ±1 % across all categories (total mean ± SD = –0.50 ± 0.90 %), with 91 % of fields passing institutional ±5 % tolerances. Further, significant differences ( p < 0.01) were also observed between treatment rooms, ion species, TPS platforms, and RaShi settings. Additionally, the RayStation TPS showed lower deviations than the Syngo TPS, and helium ions had the smallest deviations. Moreover, repeated verifications reduced variability but without significant improvement. Correlations with target depth or volume were statistically significant but clinically negligible. Less than 1 % of maximum and minimum dose measurements exceeded ±7 % annually. Finally, over 4308 h of beam time, preparation, and analysis were spent on PSQA during the 10‐year period. Conclusions: PSQA at HIT demonstrated high dosimetric accuracy and delivery stability. Integration of IDCs and log file analysis may improve efficiency and allow to omit verification measurements in well‐established cases without compromising patient safety and treatment quality, if the extensive machine QA program is maintained.


  • Open Access

    Characteristics of breathing‐adapted gating using surface guidance for use in particle therapy: A phantom‐based end‐to‐end test from CT simulation to dose delivery

    by Abdallah Qubala, Jehad Shafee, Thomas Tessonnier, Julian Horn, Marcus Winter, Jakob Naumann, Oliver Jäkel

    To account for intra‐fractional tumor motion during dose delivery in radiotherapy, various treatment strategies are clinically implemented such as breathing‐adapted gating and irradiating the tumor during specific breathing phases. In this work, we present a comprehensive phantom‐based end‐to‐end test of breathing‐adapted gating utilizing surface guidance for use in particle therapy. A commercial dynamic thorax phantom was used to reproduce regular and irregular breathing patterns recorded by the GateRT respiratory monitoring system. The amplitudes and periods of recorded breathing patterns were analysed and compared to planned patterns (ground‐truth). In addition, the mean absolute deviations (MAD) and Pearson correlation coefficients (PCC) between the measurements and ground‐truth were assessed. Measurements of gated and non‐gated irradiations were also analysed with respect to dosimetry and geometry, and compared to treatment planning system (TPS). Further, the latency time of beam on/off was evaluated. Compared to the ground‐truth, measurements performed with GateRT showed amplitude differences between 0.03 ± 0.02 mm and 0.26 ± 0.03 mm for regular and irregular breathing patterns, whilst periods of both breathing patterns ranged with a standard deviation between 10 and 190 ms. Furthermore, the GateRT software precisely acquired breathing patterns with a maximum MAD of 0.30 ± 0.23 mm. The PCC constantly ranged between 0.998 and 1.000. Comparisons between TPS and measured dose profiles indicated absolute mean dose deviations within institutional tolerances of ±5%. Geometrical beam characteristics also varied within our institutional tolerances of 1.5 mm. The overall time delays were <60 ms and thus within both recommended tolerances published by ESTRO and AAPM of 200 and 100 ms, respectively. In this study, a non‐invasive optical surface‐guided workflow including image acquisition, treatment planning, patient positioning and gated irradiation at an ion‐beam gantry was investigated, and shown to be clinically viable. Based on phantom measurements, our results show a clinically‐appropriate spatial, temporal, and dosimetric accuracy when using surface guidance in the clinical setting, and the results comply with international and institutional guidelines and tolerances.


  • Open Access

    Comparative evaluation of a surface‐based respiratory monitoring system against a pressure sensor for 4DCT image reconstruction in phantoms

    by Abdallah Qubala, Jehad Shafee, Vania Batista, Jakob Liermann, Marcus Winter, Daniel Piro, Oliver Jäkel

    Four‐dimensional computed tomography (4DCT), which relies on breathing‐induced motion, requires realistic surrogate information of breathing variations to reconstruct the tumor trajectory and motion variability of normal tissues accurately. Therefore, the SimRT surface‐guided respiratory monitoring system has been installed on a Siemens CT scanner. This work evaluated the temporal and spatial accuracy of SimRT versus our commonly used pressure sensor, AZ‐733 V.A dynamic thorax phantom was used to reproduce regular and irregular breathing patterns acquired by SimRT and Anzai. Various parameters of the recorded breathing patterns, including mean absolute deviations (MAD), Pearson correlations (PC), and tagging precision, were investigated and compared to ground‐truth. Furthermore, 4DCT reconstructions were analyzed to assess the volume discrepancy, shape deformation and tumor trajectory.Compared to the ground‐truth, SimRT more precisely reproduced the breathing patterns with a MAD range of 0.37 ± 0.27 and 0.92 ± 1.02 mm versus Anzai with 1.75 ± 1.54 and 5.85 ± 3.61 mm for regular and irregular breathing patterns, respectively. Additionally, SimRT provided a more robust PC of 0.994 ± 0.009 and 0.936 ± 0.062 for all investigated breathing patterns. Further, the peak and valley recognition were found to be more accurate and stable using SimRT. The comparison of tumor trajectories revealed discrepancies up to 7.2 and 2.3 mm for Anzai and SimRT, respectively. Moreover, volume discrepancies up to 1.71 ± 1.62% and 1.24 ± 2.02% were found for both Anzai and SimRT, respectively.SimRT was validated across various breathing patterns and showed a more precise and stable breathing tracking, (i) independent of the amplitude and period, (ii) and without placing any physical devices on the patient's body. These findings resulted in a more accurate temporal and spatial accuracy, thus leading to a more realistic 4DCT reconstruction and breathing‐adapted treatment planning.


  • Open Access

    Optimizing the Patient Positioning Workflow of Patients with Pelvis, Limb, and Chest/Spine Tumors at an Ion-Beam Gantry based on Optical Surface Guidance

    by Abdallah Qubala, Andrea Schwahofer, Stefan Jersemann, Saleh Eskandarian, Semi Harrabi, Patrick Naumann, Marcus Winter, Malte Ellerbrock, Jehad Shafee, Samira Abtehi, et al.